– 13 –
3-10. PRE BOARD
1
 BVTP 2x4
2
 PRE board
3
 Removal the solders.
– 14 –
jack (J321)
set
32 
test tape
WS-48A
(3 kHz, 0 dB)
digital frequency
counter
  TAPE SECTION     0 dB = 0.775 V
• Standard Output Level
Output terminal
HP OUT
load impedance
32 
output signal level
0.25 V (–10 dB)
• Test Tape
Type
Signal
Used for
WS-48A
3 kHz, 0 dB
tape speed adjustment
Tape Speed Adjustment
Procedure:
Mode: playback
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head magnetizer close to the erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
Mode
Torque meter
Meter reading
FWD
CQ-102C
30 – 70 g • cm
(0.42 – 0.97 oz • inch)
FWD
CQ-102C
1.5 – 5.5 g • cm
Back Tension
(0.021 – 0.076 oz • inch)
FF
CQ-201B
more than 60 g • cm
(more than 0.83 oz • inch)
REW
CQ-201B
more than 60 g • cm
(more than 0.83 oz • inch)
Tape Tension  Measurement
Mode
Tension meter
Meter Reading
FWD
CQ-403A
more than 100 g
(more than 3.53 oz)
SECTION 5
ELECTRICAL ADJUSTMENTS
SECTION 4
MECHANICAL ADJUSTMENTS
Adjust so that the value on the digital frequency counter is
3,000 Hz.
Specification Value:
Digital frequency counter
2,910 to 3,090 Hz
Adjust so that the frequency at the beginning and that at the end of
tape winding are between 2,910 to 3,090 Hz.
Adjustment Location:
Tape speed adjustment 
control inside motor
– 15 –
digital
voltmeter
100 k
TP (VT)
i
 jack (J321)
set
32 
level meter
(range: 0.5–5 V ac)
Put the lead-wire
antenna close to
the set.
AM RF signal
generator
TP (JW2)
FM RF signal
generator
0.01 
µ
F
set
  TUNER SECTION     0 dB = 1 µV
• FM Section
Setting:
RADIO (BAND) button: FM
75 kHz frequency
deviation by 1 kHz signal
output level : as low as possible
• MW/LW Section
Setting:
RADIO (BAND) button: MW or LW
30% amplitude
modulation by
400 Hz signal
• Connecting Level Meter (FM, MW and LW)
• Connecting Digital Voltmeter (FM, MW and LW)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
FM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
87.5 MHz
108 MHz
Reading on Digital voltmeter
1.6 ± 0.4 V
4.0 ± 0.3 V
Adjustment Part
<confirmation>
L2
FM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
87.5 MHz
108 MHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
10.7 MHz
MW FREQUENCY COVERAGE
CHECK
Frequency Display
531 kHz
1,611 kHz
Reading on Digital voltmeter
1.0 ± 0.5 V
5.2 ± 0.6 V
Adjustment Part
<confirmation> <confirmation>
MW TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-1
CT3
621 kHz
1,404 kHz
MW/LW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
LW FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
153 kHz
279 kHz
Reading on Digital voltmeter
0.6 ± 0.3 V
5.0 ± 0.1 V
Adjustment Part
<confirmation>
L4
LW TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-2
CT5
162 kHz
261 kHz
Adjustment Location: See page 16.
– 16 –
TP(VT)
S
G
TP
(VT)
– tuner board (conductor side) –
Adjustment Location:
  CD SECTION
CD section adjustments are done automatically in this set.
In case of operation check, confirm that focus bias.
FOCUS BIAS CHECK
1. Connect the oscilloscope between IC701 pin qg (or TP (RF))
and GND on CD board.
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01)
3. Press the CD N X button.
4. Confirm that the oscilloscope waveform is as shown in the
figure below. (eye pattern)
A good eye pattern means that the diamond shape (     ) in the
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
Test Point:
RF level :
1.2 
±
 0.3 Vp-p
VOLT/DIV : 50 mV (10 : 1 probe in use)
TIME/DIV : 500 nS
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
TP
(VT)
IC1
IC2
CNP1
JW2
ANT1
FM
TELESCOPIC
ANTENNA
L1
CT1
FM
TRACKING
ADJUSTMENT
L2
FM FREQUENCY
COVERAGE
ADJUSTMENT
T1
MW/LW IF
ADJUSTMENT
T2
FM IF
ADJUSTMENT
– tuner board (component side) –
LW
TRACKING
ADJUSTMENT
L3-2
CT5
L3-1
CT3
MW
TRACKING
ADJUSTMENT
L4
LW FREQUENCY
COVERAGE
ADJUSTMENT
TP
(RF)
TP
(RF)
– CD board (conductor side) –