DOWNLOAD Sony CFD-RS60CP Service Manual ↓ Size: 4.43 MB | Pages: 68 in PDF or view online for FREE

Model
CFD-RS60CP
Pages
68
Size
4.43 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
cfd-rs60cp.pdf
Date

Sony CFD-RS60CP Service Manual ▷ View online

13
CFD-RS60CP
SECTION  4
MECHANICAL  ADJUSTMENTS
SECTION  5
ELECTRICAL  ADJUSTMENTS
0 dB = 0.775 V
• Precaution
1. Clean the following parts with a denatured alcohol-moistened
swab :
record/playback heads
pinch roller
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head
demagnetizer. (Do not bring the head magnetizer close to the
erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the rated power
supply voltage (9V) unless otherwise noted.
• Torque Measurement
TAPE  SECTION
2.95 – 6.86 mN • m
(30 – 70 g • cm)
(0.42 – 0.97 oz • inch)
0.15 – 0.53 mN • m
(1.5 – 5.5 g • cm)
(0.021 – 0.076 oz • inch)
more than 5.88 mN • m
(more than 60 g • cm)
(more than 0.83 oz • inch)
more than 5.88 mN • m
(more than 60 g • cm)
(more than 0.83 oz • inch)
CQ-102C
CQ-102C
CQ-201B
CQ-201B
Mode
FWD
FWD
back tension
FF
REW
Torque meter
Meter reading
more than 100 g
(more than 3.53 oz)
CQ-403A
Mode
FWD
Torque meter
Meter reading
• Tape Tension  Measurement
• Standard Output Level
Output terminal
HP OUT
load impedance
32 
output signal level
0.25 V (–10 dB)
• Test Tape
Type
Signal
Used for
WS-48A
3 kHz, 0 dB
tape speed adjustment
Tape Speed Adjustment
Procedure:
Mode: playback
Adjust so that the value on the digital frequency counter is
3,000 Hz.
Specification Value:
Digital frequency counter
2,910 to 3,090 Hz
Adjust so that the frequency at the beginning and that at the end of
tape winding are between 2,910 to 3,090 Hz.
Adjustment Location:
jack (J371)
set
32 
test tape
WS-48A
(3 kHz, 0 dB)
digital frequency 
counter
Tape speed adjustment
control inside motor
14
CFD-RS60CP
TUNER  SECTION
0 dB = 1 
µ
V
[AM]
Setting:
Function: RADIO
Band: AM
[FM]
Setting:
Function: RADIO
BAND button: FM
• Repeat the procedures in each adjustment several times, and
the  tracking adjustments should be finally done by the trimmer
capacitors.
• Remove FM antenna in FM adjustment.
AM/MW RF signal 
generator
30% amplitude
modulation by
400 Hz signal
Output level: 
as low as possible
Put the loop
antenna close to 
the set.
+
level meter 
set
32 
i
 jack (J371)
FM RF signal
generator
75 kHz frequency
deviation by 1 kHz
signal
Output level: 
as low as possible
+
level meter 
set
32 
0.01 
µ
F
TUNER board
TP (GND)
TUNER board
TP-ANT(JW2)
i
 jack (J371)
digital voltmeter 
TP (CV)
TP (GND)
100 k
TUNER board
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter
T1
450 kHz
AM FREQUENCY COVERAGE ADJUSTMENT (MX model)
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L4
530 kHz
1.0 
±
 0.05 V
Confirmation
1,710 kHz
5.3 
±
 0.7 V
AM FREQUENCY COVERAGE ADJUSTMENT (EXCEPT MX model)
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L4
531 kHz
1.0 
±
 0.05 V
Confirmation
1,611 kHz
4.8 
±
 0.7 V
AM TRACKING ADJUSTMENT (MX model)
Adjust for a maximum reading on level meter
L3
620 kHz
CT3
1,400 kHz
AM TRACKING ADJUSTMENT (EXCEPT MX model)
Adjust for a maximum reading on level meter
L3
621 kHz
CT3
1,404 kHz
FM IF ADJUSTMENT
Adjust for a minimum reading on level meter
T2
10.7 MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L2
108 MHz
3.0 
±
 0.2 V
Confirmation
87.5 MHz
1.3 
±
 0.3 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1
87.5 MHz
CT1
108 MHz
• Abbreviation
MX
: Mexican model.
Adjustment and Connecting Location:
TUNER board (See page 15)
Ver. 1.1
15
CFD-RS60CP
Adjustment and Connecting Location:
L3
AM TRACKING ADJUSTMENT
CT1
FM FREQUENCY
COVERAGE
ADJUSTMENT
L2
FM FREQUENCY
COVERAGE
ADJUSTMENT
L4
AM FREQUENCY COVERAGE
ADJUSTMENT
CT3
AM TRACKING 
ADJUSTMENT
TP-ANT
(JW2)
IC1
– TUNER BOARD (Component Side) –
TP
(GND)
TP
(CV)
TP-ANT
JW2
– TUNER BOARD (Conductor Side) –
L1
FM TRACKNG
ADJUSTMENT
T1
AM IF
ADJUSTMENT
T2
FM IF
ADJUSTMENT
16
CFD-RS60CP
[TEST  DISC  LIST]
Use the following test disc on test mode.
• CD:
YEDS-18 (PART No. 3-702-101-01)
or
PATD-012 (PART No. 4-225-203-01)
Note:
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10MW impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
[S-CURVE  CHECK]
Procedure :
1. Connect an oscilloscope to TP106 (FE) and TP124 (VC).
2. Turn the power on.
3. Load a disc (YEDS-18) and actuate the focus search. (In
consequence of open and close the disc tray, actuate the focus
search).
4. Confirm that the oscilloscope waveform (S-curve) is
symmetrical between A and B. And confirm peak to peak level
within 1.7 
±
 0.7 Vp-p.
Note:
• Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the brightness
to obtain best waveform.
CD  SECTION
+
TP106 (FE)
TP124 (VC)
oscilloscope 
BD91 board
symmetry
S-curve waveform
within 1.7 
±
0.7Vp-p
A
B
[RF  LEVEL  CHECK]
Procedure :
1. Connect an oscilloscope to TP123 (RFO) and TP124 (VC).
2. Turn the power on.
3. Load a disc (YEDS-18) and playback.
4. Confirm that oscilloscope waveform is clear and check if RF
signal level is correct or not.
Note:
Clear RF signal waveform means that the shape “
◊” can be clearly
distinguished at the center of the waveform.
Connecting Location: CD board
+
TP123 (RFO)
TP124 (VC)
oscilloscope 
BD91 board
RFMON signal waveform
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level: 1.3 
±
 0.3 Vp-p 
IC401
– BD91 Board (SIDE B) –
TP124
(VC)
TP123
(RFO)
TP106
(FE)
IC101
1
1
14
15
28
25
26
50
51
75
76
100
Page of 68
Display

Click on the first or last page to see other CFD-RS60CP service manuals if exist.