13
CFD-G70L
4-1. MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belts
capstan
2. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head demagnetizer close to the erase
head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the rated power sup-
ply voltage (12V) unless otherwise noted.
Torque Measurement
Torque
Torque Meter
Meter Reading
1.77 – 5.88 mN•m
Forward
CQ-102C
(18 – 60 g•cm)
(0.25 – 0.83 oz•inch)
Forward
0.1 – 0.49 mN•m
Back Tension
CQ-102C
(1.0 – 5.0 g•cm)
(0.014 – 0.069 oz•inch)
4.42 – 9.31 mN•m
Fast Forward
CQ-201B
(45 – 95 g•cm)
(0.62 – 1.32 oz•inch)
4.42 – 9.31 mN•m
Rewind
CQ-201B
(45 – 95 g•cm)
(0.62 – 1.32 oz•inch)
Tape Tension  Measurement
Torque Meter
Meter Reading
CQ-403A
more than 60g
(more than 2.12 oz)
SECTION 4
ADJUSTMENTS
4-2. ELECTRICAL ADJUSTMENTS
 TAPE RECORDER SECTION
Standard Output Level
Output terminal
HP OUT
load impedance
32 
output signal level
0.25V (–10dB)
Test Tape
Type
Signal
Used for
WS-48A
3kHz, 0dB
Tape Speed Adjustment
Tape Speed Adjustment
Procedure :
Mode : Playback
Adjustment so than the value on the digital frequency counter is
3,000 Hz.
Adjustment Value : 3,000Hz
Standard Value : 2,940 - 3,060Hz
Frequency difference between the beginning and the end of the tape
should be within 1.5% (45Hz).
set
test tape
WS-48A
(3kHz, 0dB)
32
digital frequency
counter
J391 ( 
i
 jack)
Tape speed adjustment 
control inside motor
 0dB = 0.775V
Adjustment Location : Mechanism deck
14
CFD-G70L
MW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
(     ): AR
MW FREQUENCY COVERAGE CHECK
Frequency Display
531 kHz
1,611 kHz
(530 kHz)
(1,610 kHz)
Reading on Digital voltmeter
0.9 
± 0.4 V
5.2 
± 0.5V
Adjustment Part
<confirmation>
<confirmation>
(     ): AR
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
CT3
621kHz (620 kHz)
1,404 kHz (1,400kHz)
LW FREQUENCY COVERAGE CHECK
Frequency Display
153 kHz
279 kHz
Reading on Digital voltmeter
0.6 
± 0.2 V
5.0 
± 0.2V
Adjustment Part
< L 4 >
<confirmation>
LW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
CT5
162 kHz
261 kHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
10.7 MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Frequency Display
87.5 MHz
108 MHz
Reading on Digital voltmeter
1.3 
± 0.4 V
3.0 
± 0.3 V
Adjustment Part
<confirmation>
L2
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
87.5 MHz
108 MHz
Adjustment Location : Main board (See page 16)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
 TUNER  SECTION
 MW/LW Section
Function switch : MW/LW
Volume
: MIN
 FM Section
Function switch : FM
Volume
: MIN
• Connecting Level Meter (FM/MW/LW)
• Connecting Digital Voltmeter (FM/MW/LW)
AM  RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
Put the lead-wire
antenna close to 
the set.
FM RF signal
generator
33.75kHz frequency deviation by 
1kHz signal.
Output level : as low as possible
telescopic
antenna
terminal
0.01
µF
 0dB = 1 
µV
J391 ( i jack)
set
32 
level meter
(range: 0.5–5 V ac)
digital
voltmeter
100 k
TP (VT)
15
CFD-G70L
Focus Bias Check
1. Connect the oscilloscope between TP (RF) and GND on CD
board.
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01) (CD)
3. Press the u button two times (LPC ON).
4. Confirm that the oscilloscope waveform is as shown in the fig-
ure below. (eye pattern)
A good eye pattern means that the diamond shape (
◊) in the cen-
ter of the waveform can be clearly distinguished.
5. Press the u button.(LPC OFF)
6. Perform confirmation in step 4 again.
RF Signal Reference Waveform (eye pattern)
RF level
0.83 – 0.87 Vp-p (LPC ON)
0.82 – 0.88 Vp-p (LPC OFF)
VOLT/DIV : 200mV
TIME/DIV : 500 nS
CD SECTION
Perform all CD section check and all adjustments in the test mode.
How to put the set into CD test mode
1. Press the POWER button turn the set ON.
2. Press the FUNCTION button to select CD.
3. Set Tset mode by momentarlly shorting both side of TEST A.
4. Press the x button two times. The set is into CD test mode.
(
88 is displayed)
5. Turn the power off to release test mode.
When observing the eye pattern, set the oscilloscope for AC range
and raise certical sensitivity.
CONTROL-1 BOARD
S404
S402
S403
S401
KH402
D401
R401
R402
R403
R404
R407
 
 
 
SOUND
(TEST A)
MODE
GAME/LINE
GAME Xpand
GAME Xpand
TEST mode : momentarily short
(Conductor side)
1-68
Q701
C729
C730
R730
R728
R729
C704
R708
C72
8
R726
R707
C70
FB70
C736
C734
IC701
R709
C705
R704
R702
R711
R710
R703
R705
R701
C703
C731
R706
R727
R712
R7
C708
C751
JC703
C743
C744
C74
C742
JW707
C707
C717
C732
C702
C701
JW708
JW709
JW713
JW714
JW723
JW
JW725
JW726
C750
C
7
C747
JW711
C733
C706
JW712
JW710
oscilloscope
(AC range)
TP (RF)
(GND)
CD BOARD   (Conductor side)
TP (RF)
16
CFD-G70L
Adjustment Location :
TUNER BOARD   
(Component side)
CT1: FM Tracking Adjustment
L1: FM Tracking Adjustment
L3: MW Tracking Adjustment
CT3: MW Tracking Adjustment
CT5: LW Tracking Adjustment
CNP1
L4: LW Frequency Coverage Adjustment 
T1: MW IF Adjustment 
L3: LW Tracking Adjustment 
T2: FM IF Adjustment 
L2: FM Frequency Coverage Adjustment 
Page of 52