Sony CFD-G700CP / CFD-G770CP / CFD-G770CPK Service Manual ▷ View online
21
CFD-G700CP/G770CP/G770CPK
SECTION 4
TEST MODE
[MC COLD RESET]
The cold reset clears all data including preset data stored in the
memory to initial conditions. Execute this mode when returning
the set to the customer.
Procedure:
memory to initial conditions. Execute this mode when returning
the set to the customer.
Procedure:
1. In the standby status, press the POWER button to turn the
power on.
2. Press three buttons of x , MODE and at last POWER si-
multaneously.
3. When “RESET” appears, the machine enters standby status.
[PANEL TEST MODE]
Enter The Panel Test Mode
Procedure:
1. In the standby status, press the POWER button to turn the
power on.
2. Press three buttons of REPEAT , x , and DSPL/ENT si-
multaneously.
3. When the panel test mode is activated, LEDs and segments of
LCD are all turned on.
Version Check
Procedure:
1. In the panel test mode (all LEDs and segments of LCD are
turned on), press the ROCK button.
2. On the LCD, date and version are displayed “xxxxxxxx”.
For example, “1127V103”.
3. From this status, press the DANCE button, and the destination
is displayed. For example, “1014 AU6” or “1014 U2”
4. To release from this mode, press three buttons of REPEAT ,
x , and DSPL/ENT simultaneously.
[CHANGE-OVER THE AM TUNING INTERVAL]
(G770CP)
(G770CP)
The AM tuning interval can be changed over 9 kHz or 10 kHz.
Procedure:
Procedure:
1. Press the POWER button to turn the power on.
2. Press the RADIO/BAND button to select TUNER (AM)
2. Press the RADIO/BAND button to select TUNER (AM)
function.
3. Select the AM BAND mode and press the DSPL/ENT button
for an extended time in the AM BAND state.
4. Then, press the AUTO PRESET/RADIO/BAND for an
extended time.
5. Next, press the PRESET + PRESET – button select either
9k/10k.
6. Finally, press the DSPL/ENT button to set the selected step.
[CD SERVICE MODE]
This mode can move the SLED of the optical pick-up, and also can
turn the optical pick-up laser power on and off.
Procedure:
turn the optical pick-up laser power on and off.
Procedure:
1. Press the POWER button to turn the power on.
2. Press three buttons of x , VOL + , and SALSA simulta-
2. Press three buttons of x , VOL + , and SALSA simulta-
neously.
3. It enters the CD service mode and displays “SERVICE”.
4. To exit from this mode, press three buttons of x , VOL + ,
4. To exit from this mode, press three buttons of x , VOL + ,
and SALSA simultaneously.
Key Operation:
PRESET+ > , PRESET– . :
Use these keys to move the SLED.
When PRESET+ > is pressed in this mode, the
SLED moves to outer circumference and the message
“SLED OUT” is displayed.
When PRESET– . is pressed in this mode, the
SLED moves to inner circumference and the message
“SLED IN” is displayed.
When PRESET+ > is pressed in this mode, the
SLED moves to outer circumference and the message
“SLED OUT” is displayed.
When PRESET– . is pressed in this mode, the
SLED moves to inner circumference and the message
“SLED IN” is displayed.
MODE :
Use this key to turn the optical pick-up laser power
on and off. When the laser power is turned on, the
message “LD ON” is displayed. When the laser
power is turned off, the message “LD OFF” is
displayed.
on and off. When the laser power is turned on, the
message “LD ON” is displayed. When the laser
power is turned off, the message “LD OFF” is
displayed.
[CD ERROR CODE]
The past errors of the optical pick-up system (= optical unit + BD
board) is displayed as the BD Errors as shown below.
Procedure:
board) is displayed as the BD Errors as shown below.
Procedure:
1. Press the POWER button to turn the power on.
2. Press three buttons of VOL + , x and DANCE simulta-
2. Press three buttons of VOL + , x and DANCE simulta-
neously.
3. Then, the BD error code is displayed as “D0xxxxxx” (x means
hexadecimal number) on the LCD screen as shown below.
4. Every pressing of the PRESET+ > button in this mode
increments the number after “D” starting from “D0” up to
“D4”, and then returns to “D0”. Every pressing of the
PRESET– . button in this mode decrements the number
after “D”. The smaller the error code number is, the newer the
error content is.
“D4”, and then returns to “D0”. Every pressing of the
PRESET– . button in this mode decrements the number
after “D”. The smaller the error code number is, the newer the
error content is.
5. To exit from this mode, press the POWER button to turn the
power off.
22
CFD-G700CP/G770CP/G770CPK
Contents of “BD Errors”
Error display example
D 0 02 09 01
1 2 3 4
1
It indicates the error history number
0 to 4: The error code number 0 indicates the newest error.
0 to 4: The error code number 0 indicates the newest error.
2
It indicates the error content
01: The focus servo cannot lock-in.
02: GFS is no good (NG).
03: The startup time exceeds the specified period of time (time
01: The focus servo cannot lock-in.
02: GFS is no good (NG).
03: The startup time exceeds the specified period of time (time
over)
04: The focus servo is unlocked continuously.
05: Q code cannot be obtained within the specified period of
05: Q code cannot be obtained within the specified period of
time.
06: The tracking servo cannot lock-in.
07: Blank disc
07: Blank disc
3
It indicates the on-going processing of optical pick-up system
(= optical unit + BD board) when the trouble has occurred.
01: The CD SHIP mode processing is in progress.
02: The POWER OFF processing is in progress.
03: The INITIALIZE processing is in progress.
04: The optical pick-up system (= optical unit + BD board)
(= optical unit + BD board) when the trouble has occurred.
01: The CD SHIP mode processing is in progress.
02: The POWER OFF processing is in progress.
03: The INITIALIZE processing is in progress.
04: The optical pick-up system (= optical unit + BD board)
is in the stop state.
05: The STOP operation is in progress.
06: The startup processing is in progress.
07: The TOC read-in processing is in progress.
08: The SEARCH operation is in progress.
09: The PLAY operation is in progress.
0A: The PAUSE operation is in progress.
0B: The PLAY – MANUAL SEARCH operation is in
06: The startup processing is in progress.
07: The TOC read-in processing is in progress.
08: The SEARCH operation is in progress.
09: The PLAY operation is in progress.
0A: The PAUSE operation is in progress.
0B: The PLAY – MANUAL SEARCH operation is in
progress.
0C: The PAUSE – MANUAL SEARCH operation is in
progress.
4
It indicates the operation that is being processed when the
trouble has occurred.
It indicates the step number of each processing specified by
3
trouble has occurred.
It indicates the step number of each processing specified by
3
. Because the numbers of steps are different in each
processing, this number is different in each processing.
23
CFD-G700CP/G770CP/G770CPK
•
Precaution
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head
demagnetizer. (Do not bring the head magnetizer close to the
erase head.)
erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, appiy suitable locking compound to
4. After the adjustments, appiy suitable locking compound to
the parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
•
Torque Measurement
•
Tape Tension Measurement
Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 80 g • cm
(more than 2.82 oz • inch)
2.0 – 8.0 mN • m
(20 to 80 g • cm)
(0.28 – 1.12 oz • inch)
0.15 – 0.6 mN • m
(1.5 to 6 g • cm)
(0.021 – 0.083 oz • inch)
5 – 17.7 mN • m
(50 to 177 g • cm)
(0.7 – 2.48 oz • inch)
5 – 17.7 mN • m
(50 to 177 g • cm)
(0.7 – 2.48 oz • inch)
CQ-102AS
CQ-102C
CQ-201AS
CQ-201B
Mode
FWD
FWD
back tension
FF
REW
Torque meter
Meter reading
SECTION 6
ELECTRICAL ADJUSTMENTS
SECTION 5
MECHANICAL ADJUSTMENTS
Checking Location:
+
–
–
BD90 board
TP (RFI)
TP (VC)
TP (VC)
oscilloscope
(DC range)
Procedure :
1. Connect oscilloscope to TP (RFI) and TP (VC) on the BD90
board.
2. Press the POWER button to turn the power ON, and press
the Z PUSH OPEN/CLOSE button to open the CD disc tray.
3. Set disc (YEDS-18) on the tray and press the u (CD) button
to playback.
4. Confirm that oscilloscope waveform is as shown in the figure
below. (eye pattern)
A good eye pattern means that the diamond shape (
A good eye pattern means that the diamond shape (
◊
) in the
center of the waveform can be clearly distinguished.
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
TIME/DIV: 500 ns
level:
1.2
1.2
±
0.3 Vp-p
TP
(VC)
TP
(RFI)
IC101
– BD90 Board (Side B) –
CD SECTION
Note:
1.
CD Block is basically constructed to operate without adjustment.
2.
Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10 M
Ω
impedance.
4.
Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
5.
Check the focus bias check when optical pick-up block is replaced.
FOCUS BIAS CHECK
24
CFD-G700CP/G770CP/G770CPK
Adjustment Location:
Tape speed adjustment
control inside motor
(M971)
control inside motor
(M971)
i
jack (J391)
set
32
Ω
test tape
WS-48A
(3 kHz, 0 dB)
WS-48A
(3 kHz, 0 dB)
digital frequency
counter
counter
• Test Tape
Type
Signal
Used for
WS-48A
3 kHz, 0 dB
tape speed adjustment
Tape Speed Adjustment
Procedure:
Mode: playback
Adjust so that the value on the digital frequency counter is
3,000 Hz.
Mode: playback
Adjust so that the value on the digital frequency counter is
3,000 Hz.
Specification Value:
Digital frequency counter
2,940 to 3,060 Hz
Adjust so that the frequency at the beginning and that at the end of
tape winding are between 2,970 to 3,030 Hz.
tape winding are between 2,970 to 3,030 Hz.
Adjustment Location: Record/Playback/Erase Head
RECORD/PLAYBACK HEAD AZIMUTH ADJUSTMENT
Procedure:
1. Mode: Playback
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
so that outputs match within 1dB of peak.
3. Mode: Playback
4. After the adjustments, apply suitable locking compound to
the pats adjusted.
Screw
position
position
L-CH
peak
peak
within
1dB
1dB
Output
level
level
L-CH
peak
peak
R-CH
peak
peak
within
1dB
1dB
Screw
position
position
R-CH
peak
peak
0 dB=0.775 V
set
i
jack
(J391)
+
–
–
level meter
test tape
P-4-A063
(6.3 kHz,
P-4-A063
(6.3 kHz,
−
10 dB)
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
•
Test Tape
Tape
Signal
Used for
P-4-A063
6.3 kHz, –10 dB
Azimuth Adjustment
set
test tape
P-4-A063
(6.3 kHz,
P-4-A063
(6.3 kHz,
−
10 dB)
oscilloscope
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
i
jack
(J391)
TAPE SECTION
Click on the first or last page to see other CFD-G700CP / CFD-G770CP / CFD-G770CPK service manuals if exist.