DOWNLOAD Sony CFD-G35 Service Manual ↓ Size: 10.02 MB | Pages: 52 in PDF or view online for FREE

Model
CFD-G35
Pages
52
Size
10.02 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
cfd-g35.pdf
Date

Sony CFD-G35 Service Manual ▷ View online

11
CFD-G35
3-12.  MAIN Board- 2
5
 MAIN board
CNP374
CNP353
chassis (CD)
L-R/REG board
1
 from TUNER board CNP1
2
 from HEADPHONE board CNP391
3
 from HEADPHONE board CNP393
4
 from POWER board CNP903
PDW board
3-13.  Mechanism Deck Section (MF-V5-117)
4
 t
hree screws
     +BVTP 3 
×
 10
1
 f
lexible flat cable
    (from MAIN board CNP805)
5
 m
echanism deck section
     (MF-V5-117)
3
 
TC board
2
 s
crew
     +PTT 2 
×
 6
12
CFD-G35
3-14.  CD Block Section (KSM-213RDP)
3-15.  PDW, L-R/REG Board
4
 
CD board
3
 f
lexible flat cable
     CNP701
2
 
Remove solderings 
    from the four points.
1
 f
lexible flat cable 
     (from MAIN board CNP802)
6
 
CD block section
     (KSM-213RDP)
5
 f
our screws
     2.6 
×
 10 (DIA, 10),+WH
5
 three
 screws
     +BVTP 3 
×
 10
1
 s
crew
     +BVTP 3 
×
 10
3
 t
wo screws
     +BVTP 3 
×
 10
6
 PDW board,
     Chassis (HS, R)
4
 L-R/REG board,
     Chassis (HS, L)
2
 clamp
13
CFD-G35
4-1. Mechanical Adjustments
PRECAUTION
1.
Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belts
capstan
2.
Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head demagnetizer close to the erase
head.)
3.
Do not use a magnetized screwdriver for the adjustments.
4.
The adjustments should be performed with the rated power
supply voltage (9V) unless otherwise noted.
Torque Measurement
Torque
Torque Meter
Meter Reading
1.77 – 5.88 mN•m
Forward
CQ-102C
(18 – 60 g•cm)
(0.25 – 0.83 oz•inch)
Forward
0.1 – 0.49 mN•m
Back Tension
CQ-102C
(1.0 – 5.0 g•cm)
(0.014 – 0.069 oz•inch)
4.42 – 9.31 mN•m
Fast Forward
CQ-201B
(45 – 95 g•cm)
(0.62 – 1.32 oz•inch)
4.42 – 9.31 mN•m
Rewind
CQ-201B
(45 – 95 g•cm)
(0.62 – 1.32 oz•inch)
Tape Tension  Measurement
Torque Meter
Meter Reading
CQ-403A
more than 60g
(more than 2.12 oz)
SECTION 4
ADJUSTMENTS
4-2. Electrical Adjustments
 TAPE SECTION
Standard Output Level
Output terminal
HP OUT
load impedance
32 
output signal level
0.25V (–10dB)
Test Tape
Type
Signal
Used for
WS-48A
3kHz, 0dB
Tape Speed Adjustment
Tape Speed Adjustment
Procedure :
Mode : Playback
Adjustment so than the value on the digital frequency counter is
3,000 Hz.
Adjustment Value : 3,000Hz
Standard Value : 2,940 - 3,060Hz
Frequency difference between the beginning and the end of the tape
should be within 1.5% (45Hz).
set
test tape
WS-48A
(3kHz, 0dB)
32
digital frequency
counter
J391 
(
 
i
 
)
Tape speed adjustment 
control inside motor
 0dB = 0.775V
Adjustment Location : Mechanism deck
14
CFD-G35
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
no mark : EXCEPT AUS,
AR, SP
(    )
: AUS, SP
<  >
: AR
AM FREQUENCY COVERAGE ADJUSTMENT
Frequency Display
530 kHz
1,710 kHz
(531 kHz)
(1,611 kHz)
<530 kHz>
<1,610 kHz>
Reading on Digital voltmeter
1.0 ± 0.1 V
5.3 ± 0.8V
(4.8 ± 0.8V)
<4.8± 0.8V>
Adjustment Part
 L 4
<confirmation>
no mark : EXCEPT AR
<  >
: AR
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
CT3
620 kHz 
<
621
kHz>
1,400 kHz <1,404 kHz>
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
10.7 MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Frequency Display
87.5 MHz
108 MHz
Reading on Digital voltmeter
1.3 ± 0.4 V
3.0 ± 0.3 V
Adjustment Part
<confirmation>
L2
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
87.5 MHz
108 MHz
Abbreviation
AR : Argentina model.
AUS : Australian model.
SP
: Singapore model.
Adjustment Location : TUNER board (See page 16)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
 TUNER SECTION
 AM Section
Function switch : AM
 FM Section
Function switch : FM
• Connecting Level Meter (FM and AM)
• Connecting Digital Voltmeter (FM and AM)
AM  RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
Put the lead-wire
antenna close to 
the set.
FM RF signal
generator
33.75kHz frequency deviation by 
1kHz signal.
Output level : as low as possible
telescopic
antenna
terminal
0.01
µ
F
 0dB = 1 
µV
digital
voltmeter
100 k
TP  CV
J391 
(
 
i
 
)
set
32 
level meter
(range: 0.5–5 V ac)
Ver 1.1  2002. 05
Page of 52