DOWNLOAD Sony CFD-930L / CFD-V34L / CFD-V37L Service Manual ↓ Size: 1.48 MB | Pages: 34 in PDF or view online for FREE

Model
CFD-930L CFD-V34L CFD-V37L
Pages
34
Size
1.48 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
cfd-930l-cfd-v34l-cfd-v37l.pdf
Date

Sony CFD-930L / CFD-V34L / CFD-V37L Service Manual ▷ View online

— 13 —
FM VCO Adjustment
Procedure :
1. Connect frequency counter to the positions shown below.
2. Tune the set to 98MHz.
3. Adjust RV1 for 75.950kHz to 76.050kHz reading on the
frequency counter.
0.01
µ
F
FM RF SSG
to ANT IN terminal
Carrier frequency : 98MHz
IF frequency : According to
the color of CF1.
Modulation : no modulation
Output level : 0.1V (100dB)
Frequency counter
0.01
µ
F
+
33k 
IC1 Pin 
4
IC1 Pin 
7
RED
10.70MHz
BLUE
10.67MHz
ORANGE
10.73MHz
BLACK
10.64MHz
WHITE
10.76MHz
color
mark
CF1
Adjustment Location : MAIN board (Component side)
CT7
CT8
L11
L4
L2
L3
T2
T1
L1
CV1
RV1
IC701
CV1 (1/4)
CV1 (2/4)
L1
L2
FM Tracking
CV1 (3/4)
RV1 : FM VCO
L3 (MW)
MW/AM Tracking Adjustment
FM Reception Frequency 
Coverage Check
L11
CT8
LW Reception Frequency 
Coverage Check
L4
CV1 (4/4)
MW/AM Reception Frequency 
Coverage Check
CT7
L3 (LW)
ANT IN
LW Tracking Adjustment
T1 : FM IF
IC1 : VCO IN
IC1
11
18
1
30
4
FM IF IN
T2 : AM IF
— 14 —
Notes on Check
1.
Perform the traverse check in the CD test mode.
After check, be sure to exit the test mode.
2.
Perform check in the order given.
3.
Use the disc (YEDS-18, Parts No. 3-702-101-01) only when
so indicated.
Before Check
Put the set into test mode and perform the following  checks.
Repair if there are any problems.
• Sled Motor Check
Press 
+ , = keys and confirm that the Optical pick-up  moves
smoothly from the innermost to outermost circumference and back
smoothly and with no catching or abnormal noises.
(Cancellation of BTL mute)
+ : Optical pick-up moves to the outer circumference.
= : Optical pick-up moves to the inner circumference.
Focus Search Check
1.
Press the CD 
^ key. (Focus search operation is performed
continuously.)
2.
Look at the Optical pick-up objective lens and confirm that it
moves up and down smoothly, with no catching or abnormal
noises.
3.
Press 
p button.
Confirm that focus search operation stops. If it does not, press
p button again longer.
How to Enter the Set into Test Mode
1.
Turn the AC CORD IN (Adaptor).
(LCD 501 indicator blinks the test mode pattern.)
2.
Short-circuit between the lands as shown on the control (1)
board.
How to Exit the Test Mode
Turn the POWER OFF.
[CONTROL (1) BOARD]
CD SECTION
E-F Balance Check
Adjustment Location : MAIN board (See page 23)
This check is to be done when the optical pick-up block is replaced.
Check Procedure:
1.
Connect the oscilloscope to test point TP (VC) and TP (TE) on
MAIN board.
2.
Put the set into test mode.
3.
Optical pick-up setting to the center by 
+ or = button
pushing.
4.
Insert disk (YEDS-18) and press 
^ button.
5.
Check that the oscilloscope traverse waveform is symmetrical,
as shown in the figure below.
6.
Release test mode after adjustment is completed.
[MAIN BOARD]
A
B
C
0V
VOLT/DIV : 0.1V
TIME/DIV  : 1ms
A = B     C = 400mV to 600mV
Jumper wire
Test portion
Short : Test mode
Open : Normal mode
TP(FE)
TP(RF)
TP(TE)
TP(TE)
TP(VC)
TP(VC)
Osilloscope
(DC range)
+
— 15 —
Focus Bias Check
Adjustment Location : MAIN board (Component side)
(See page 23)
This check is to be done when the optical block replaced.
Check Procedure:
1. Connect the oscilloscope to test point TP (VC) and TP (RF) on
MAIN board.
2. Put the set into test mode.
3. Opitical pick-up setting to the center by + or – button pushing.
4. Insert disk (YEDS-18) and press 
^ button.
5. Press the MODE button. (Tracking servo ON)
6. Check that the oscilloscope wavewform is as shown in the figure
below (eye pattern).
A good eye pattern means that the diamond shape (
) in the
center of the waveform can be clearly distinguished.
7. Release test mode after adjustment is completed.
• RF signal reference waveform (eye pattern)
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensivity.
[MAIN BOARD]
4-4.
REFERENCE
Focus/Tracking Gain Check
Adjustment Location : MAIN board (Component side)
(See page 23)
A frequency response analyzer is necessary in order to perform this
check exactly.
However, this gain has a margin, so even if it is slightly off, there is
no problem.
Focus/Tracking gain determines the pick-up follow-up (vertical and
horizontal) relative to mechanical noise and mechanical shock when
the 2-axis device operate.
Tracking
Gain
Symptoms
Focus
•  The time until music starts
becomes longer for STOP ➡
CD 
^ or automatic
selection (
0 , ) buttons
pressed). (Normally takes
about 2 seconds.)
•  Music does not start and disc
continues to rotate for STOP
➡ CD ^ or automatic
selection (
0 , ) buttons
pressed.)
•  Sound is interrupted during
PLAY. Or time counter
display stops progressing.
•  More noise during 2-axis
device operation.
low
high
low or high
low
low
high
VOLT/DIV : 0.2V
TIME/DIV : 500ns
1.0 to 1.4 Vp-p
Check Procedure:
1. Keep the set horizontal.
2. Inset disk (YEDS-18) and press 
^ button.
3. Connect an oscilloscope to TP (FE) and TP (VC) on the MAIN
board.
4. Check that the waveform is as shown in the figure below. (Focus
waveform)
TP(FE)
TP(RF)
TP(TE)
TP(
Osilloscope
(DC range)
+
— 16 —
Good Example
Incorrent Examples (DC level changes more than on adjusted
waveform)
5.
Connect an oscilloscope between TP (TE) and TP (VC).
6.
Insert disc (YEDS-18) and press the CD 
^ button.
7.
Check that the waveform is as shown in the figure below.
(tracking waveform)
low focus gain
high focus gain
low tracking gain
high tracking gain
(high fundamental wave than for low gain)
[MAIN BOARD]
100mV
0V
VOLT/DIV : 100mV
TIME/DIV : 1ms
VOLT/DIV : 100mV
TIME/DIV : 2ms
200mV
0V
VOLT/DIV : 100mV
TIME/DIV : 2ms
75mV
0V
VOLT/DIV : 1V
TIME/DIV : 2ms
0V
VOLT/DIV : 1V
TIME/DIV : 2ms
0V
VOLT/DIV : 1V
TIME/DIV : 2ms
0V
TP(FE)
TP(RF)
TP(TE)
TP(TE)
TP(FE)
TP(VC)
TP(VC)
Osilloscope
(DC range)
+
Incorrect Examples (Fundamental wave appears)
Page of 34
Display

Click on the first or last page to see other CFD-930L / CFD-V34L / CFD-V37L service manuals if exist.