– 9 –
 TUNER  SECTION
• Switch location
FUNCTION
: RADIO
VOLUME
: MAX
MEGA BASS
: mechanical center
ROTARY  EQUALIZER : center click
 AM Section
BAND : AM
 FM Section
BAND : FM
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
AM IF ALIGNMENT
Adjust for a maximum reading on level meter.
CFT1
455kHz
AM FREQUENCY COVERAGE  ADJUSTMENT
Adjust part
Frequency display
Reading on digital
voltmeter.
Confirmation
530kHz
0.9 ± 0.2V
L4
1,710kHz
5.6 ± 0.2V
AM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
620kHz
CT2
1,400kHz
FM FREQUENCY COVERAGE  ADJUSTMENT
Adjust part
Frequency display
Reading on digital
voltmeter.
Confirmation
87.5MHz
1.7 ± 0.2V
L2
108MHz
4.0 ± 0.2V
FM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
87.5MHz
CT1
108MHz
Adjustment Location : MAIN board (See page 12)
Frequency Coverage Adjustment
Setting :
       [MAIN BOARD]
       (Conductor side)
AM  RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
Put the lead-wire
antenna close to 
the set.
FM RF signal
generator
22.5kHz frequency deviation by 400Hz signal.
Output level : as low as possible
telescopic
antenna
terminal
0.01
µ
F
set
32
+
J302(phones)
level meter
R3
C83
+
Digital voltmeter
(DC range)
3. Phase Check
Mode : Playback
4. After the adjustment, lock the screws with locking compound.
Adjustment Location :
V
H
in phase
90
°
45
°
135
°
180
°
good
wrong
set
L-CH
R-CH
screen pattern
test tape
P-4-A063
(6.3kHz, –10dB)
Osilloscope
J302 (phones)
32 
32 
Deck A
Deck B
Window (C)
cassette
Screwdriver
Window (C)
cassette
– 10 –
 CD SECTION
Note on Adjustment
1. Perform adjustment in test mode.
After adjustment, be sure to release test mode.
2. Perform adjustments in the order given.
3. Use the disc (YEDS-18. Part No. 3-702-101-01) only when  so
indicated.
Before adjustment
Put the set into test mode and perform the following checks.
Repair if there are any problems.
• Sled Motor Check
1. Press 
^ button, then press OFF button.
2. Press 
+, =buttons and confirm that the Optical pick-up
moves smoothly from the innermost to outermost circumference
and back smoothly and with no catching or abnormal noises.
(Cancellation of BTL mute)
+ : Optical pick-up moves to the outer circumference
= : Optical pick-up moves to the inner circumference
•  Focus Search Check
1. Press 
^ button. (Focus search operation is performed continu-
ously.)
2. Look at the Optical pick-up objective lens and confirm that it
moves up and down smoothly, with no catching or abnormal
noises.
3. Press 
p button.
Confirm that focus search operation stops. If it does not , press
p button again longer.
Note :
When the malfunction is occurred by mis-passing
other buttons, turn off the power and check again
from making the test mode.
How to put the Set into Test Mode
1. Short-circuit between JW804 and JW812 on the switch board.
2. Turn the POWER ON.
3. Open the Short-circuit.
[SWITCH BOARD] (Conductor side)
How to Release Test Mode
1. Turn the POWER OFF.
E-F Balance Adjustment
This adjustment is to be done when the optical pick-up block is
replaced.
Adjustment Procedure :
1. Connect the oscilloscope between TP (VC) and TP (TO) on CD
board.
2. Put the set into test mode.
3. optical pick-up setting  to the center by 
+ or = button
pushing.
4. Insert disc (YEDS-18) and press 
^ button.
5. Adjust RV703 so that the oscilloscope traveres waveform is sym-
metrical, as shown in the figure below.
6. Release test mode after adjustment is completed.
[CD BOARD] (Conductor side)
Adjustment Location : CD board (See page 12)
Focus Bias Adjustment
This adjustment is to be done when the optical pick-up block is
replaced.
Adjustment procedure :
1. Connect the oscilloscope to test point TP (VC) and TP (RFO) on
CD board.
2. Put the set into test mode.
3. Optical pick-up setting to the center by 
+  or = button
pushing.
4. Insert disc (YEDS-18) and press 
^ button.
5. Press the 
^ button.  (Tracking servo ON)
A          
0V
B
C
VOLT / DIV : 1V
TIME / DIV :1ms
A = B
C = 350mV 
±
 120mV
IC701
TP (VC)
TP (TO)
+
-
TP (TO)
oscilloscope
(DC range)
TP (VC)
TP
(TEST 1)
JW804
JW812
TEST Portion
Short : Test mode
Open : Normal mode
– 11 –
The following is a simple adjustment method.
– Primary Adjustment –
Note :
 Since exact adjustment cannot be performed, re-
member the positions of the controls before per-
forming the adjustment.If the positions after the
primary adjustment are only a little different, re-
turn the controls to the original position.
Procedure :
1. Keep the set horizontal.
If the set is not horizontal, this adjustment cannot be performed
due to the gravity against the 2-axis device.
2. Insert disc (YEDS-18) and press 
^ button.
3. Connect oscilloscope to TP (FO) and TP (VC) on CD board.
4. Adjustment RV702 on CD board so that the waveform is as
shown in the figure below. (Focus gain adjustment)
VOLT/DIV : 100mV
TIME/DIV : 2ms
• Incorrect Examples (DC level changes more than on adjusted
waveform)
VOLT/DIV : 100mV
low focus gain
TIME/DIV : 2ms
VOLT/DIV : 100mV
high focus gain
TIME/DIV : 2ms
6. Adjust RV701 so that the oscilloscope waveform is as shown in
the figure below (eye pattern).
A good eye pattern means that the diamond shape (
) in the cen-
ter of the waveform can be clearly distinguished.
7. Release test mode after adjustment is completed.
• RF signal reference waveform (eye pattern)
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
[CD BOARD] (Conductor side)
Adjustment Location : CD board (See page 12)
Focus/Tracking Gain Adjustment
A frequency responce analyzer is necessary in order to perform this
adjustment exactly.
However, this gain has a margin, so even if it is slightly off, there is
no problem. Therefore, do not perform this adjustment.
Focus/tracking gain determines the pick-up follow-up (vertical and
horizontal) relative to mechanical noise and mechanical shock when
the 2-axis device operate.
However, as these reciprocate, the adjustment is at the point where
both are satisfied.
• When gain is raised, the noise when the 2-axis device operates
increases.
• When gain is lowered, mechanical shock and skipping occurs
more easily.
• When gain adjustment is off, the symptoms below appear.
1.2 
±
 0.2V 
VOLT/DIV : 0.2V
TIME/DIV: 500ns  
IC701
TP (VC)
TP (RFO)
+
-
TP (RFO)
oscilloscope
(DC range)
TP (VC)
r
The time until music starts becomes
 longer for STOP 
^
 
button or 
automatic selection.
=, + buttons pressed.)
(Normally takes about 2 seconds.)
r
Music does not start and disc
continues to rotate for STOP 
^
 
button or automatic selection.
=, + buttons pressed.)
Sound is interrupted during PLAY. 
Or time counter display stops
progressing.
r
More noise during 2-axis device
operation.
Symptoms
Gain
Focus
Tracking
low   
  low or high
           low
           low
high
            high
100mV
0V
200mV
0V
75mV
0V
– 12 –
IC701
TP (FO)
TP (VC)
TP (TO)
+
-
TP (TO)
TP (FO)
oscilloscope
(DC range)
TP (VC)
5. Connect oscilloscope to TP (TO) and TP (VC) on CD board.
6. Adjust RV704 on CD board so that the waveform is as shown in
the figure below. (Tracking gain adjustment)
7. Release test mode after adjustment is completed.
VOLT/DIV : 1V
TIME/DIV : 2ms
• Incorrect Examples (fundamental waveform appears)
low tracking gain
VOLT/DIV : 1V
TIME/DIV : 2ms
high tracking gain
High fundamental wave
than for low gain
VOLT/DIV : 1V
TIME/DIV : 2ms
Adjustment Location :
0V
0V
0V
(                                  )
CT2 : AM Tracking Adjustment
CT1 : FM Tracking Adjustment
L1 : FM Tracking Adjustment
CFT1 : AM IF Alignment
L3 : AM Tracking Adjustment
L4 : AM Frequency Coverage Adjustment
L2:FM Frequency Coverage Adjustment
[MAIN BOARD] (Component side)
[CD BOARD] (Component side)
RV702 : Focus Gain Adjustment
RV703 : E-F Balance Adjustment
RV704 : Tracking Gain Adjustment
RV701 : Focus Bias Adjustment
[CD BOARD]
Page of 35