– 17 –
DIAL  POINTER  SETTING
Note:
 
Follow the assembly procedure in the numerical order given.
4
MAIN board
Fig. A
2
pointer
1
Rotate the gear (PVC) fully
in the direction of the arrow.
3
Set the pointer
to the position
shown in Fig. A.
indicator
– 18 –
SECTION  4
MECHANICAL  ADJUSTMENTS
Mode
Torque Meter
Meter Reading
FWD
CQ-102C
27-70 g•cm
(0.38-0.97 oz•inch)
FWD
1.5-5.5 g•cm
Back tension
(0.021-0.07 oz•inch)
55-130 g•cm
FF
CQ-201B
(0.77-1.80 oz•inch)
55-130 g•cm
REW
CQ-201B
(0.77-1.80 oz•inch)
Tape Tension  Measurement
Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 100 g (3.53 oz)
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab:
record/playback head pinch roller
erase head
rubber belts
capstan
2. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring  the head demagnetizer close to the erase
head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
Torque Measurement
SECTION  5
ELECTRICAL  ADJUSTMENTS
adjustable resistor
33 
test tape
WS-48B
(3 kHz, 0dB)
set
phones jack
speed checker
LFM-30 or
digital frequency
counter
Speed checker
Digital frequency counter
–1% to +1%
2,970 to 3,030 Hz
Frequency difference between the beginning and the end of the tape
should be within 1% (30 Hz).
Adjustment Location:
TAPE  DECK SECTION
Standard Output Level
SP OUT
HP OUT
Load impedance
3.2
33
Output  level
0.775 V (0 dB)
0.25 V (–10 dB)
Test Tape
Type
Signal
Used for
WS-48B
3 kHz, 0 dB
Tape speed adjustment
0 dB=0.775 V
Tape Speed Adjustment
Procedure:
Mode: playback
Adjustment Values:
M601
– 19 –
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
(      ): UK
FM  FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a maximum reading on VTVM.
L2
86.5 MHz (87.0 MHz)
CT2
109.5 MHz (108.3 MHz)
FM  TRACKING  ADJUSTMENT
Adjust for a maximum reading on VTVM.
L1
86.5 MHz (87.0 MHz)
CT1
109.5 MHz (108.3 MHz)
AM  IF  ADJUSTMENT
Adjust for a maximum reading on VTVM.
CFT1
455 kHz
AM  FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a maximum reading on VTVM.
L4
520 kHz
CT4
1780 kHz (1680 kHz)
AM  TRACKING  ADJUSTMENT
Adjust for a maximum reading on VTVM.
L3
620 kHz
CT3
1400 kHz
VCO Adjustment
Procedure:
1. Connect frequency counter to 4 and 7 pins of IC1 as shown
the figure below.
2. Tune the set to 98 MHz.
3. Adjust RV1 for 76 kHz ± 500 Hz reading on the frequency
counter.
[MAIN BOARD]  (Conductor Side)
set
telescopic
antenna terminal
(JW7)
0.01 
µ
F
FM RF SSG
Carrier frequency: 98 MHz
Modulation: no modulation
Output level: 0.032 V (90 dB)
+
µ
F
33 k
frequency counter
+
4
7
TUNER  SECTION
[FM]
[AM]
FM RF SSG
0.01 
µ
F
22.5 kHz frequency deviation
by 400 Hz signal.
output level: as low as possible
telescopic
antenna
terminal
(JW7)
AM RF SSG
30% amplitude modulation by
400 Hz signal
output level: as low as possible
Put the lead-wire
antenna close to
the set.
Adjustment Location: MAIN board (See page 20.)
– 20 –
Adjustment Location:
[MAIN BOARD]  (Component Side)
RV1: VCO
L2: FM Frequency
Coverage
L3: AM Tracking
CFT1: AM IF
L1: FM Tracking
CT1: FM Tracking
CT3: AM Tracking
CT4: AM Frequency
Coverage
L4: AM Frequency
Coverage
CT2: FM Frequency
Coverage