Sony CFD-503 / CFD-505 Service Manual ▷ View online
– 21 –
CD SECTION
Notes on Adjustment
1. Perform adjustment in test mode.
After adjustments, be sure to release test mode.
2. Perform adjustments in the order given.
3. Use the disc (YEDS-18. Part No. 3-702-101-01) only when so
3. Use the disc (YEDS-18. Part No. 3-702-101-01) only when so
indicated.
Before Adjustment
Put the set into test mode and perform the following checks.
Repair if there are any problems.
Repair if there are any problems.
• Sled Motor Check
1. Press
^ button, then press p button.
2. Press
+, = buttons and confirm that the optical pick-up
moves smoothly from the innermost to outermost circumfer-
ence and back smoothly and with no catching or abnormal noises.
ence and back smoothly and with no catching or abnormal noises.
+ : Optical pick-up moves to the outer circumference
= : Optical pick-up moves to the inner circumference
= : Optical pick-up moves to the inner circumference
• Focus Search Check
1. Press
^ button. (Focus serch operation is performed continu-
ously.)
2. Look at the optical pick-up objective lens and confirm that it
moves up and down smoothly, when no catching or abnormal
noises.
noises.
3. Press
p button.
Confirm that focus search operation stops. If it does not , press
p button again longer.
p button again longer.
How to Put the Set into Test Mode
1. Short-circuit following portion on the CONTROL board.
2. Turn the FUNCTION selector to CD position.
2. Turn the FUNCTION selector to CD position.
[CONTROL BOARD] (Conductor Side)
E-F Balance Adjustment
This adjustment is to be done when the optical pick-up block is
replaced.
replaced.
Procedure:
+
–
–
CD MAIN board
TP (Tracking-Y)
TP (VC)
Oscilloscope
(DC range)
1. Put the set into test mode.
2. Connect oscilloscope between TP (TRACKING-Y) and TP
2. Connect oscilloscope between TP (TRACKING-Y) and TP
(VC).
3. Press
+ and = buttons to move the optical pick-up to the
center.
4. Insert disc (YEDS-18) in and press
^ button.
5. Adjust RV703 so that the oscilloscope traverse waveform is sym-
metrical, as shown in the figure below.
6. Release test mode after adjustment is completed.
A
B
0 V
A=B
VOLT/DIV: 0.2 V
TIME/DIV: 1ms
TIME/DIV: 1ms
Adjustment value: 0.5 ± 0.2 Vp-p (A + B)
Adjustment Location: CD MAIN board (See page 24.)
How to Release the Test Mode
1. Open the short-circuit to release test mode.
Short-circuit
– 22 –
Focus Bias Adjustment
This adjustment is to be done when the optical pick-up block is
replaced.
replaced.
Procedure:
REFERENCE
Focus/Tracking Gain Adjustment
A frequency responce analyzer is necessary in order to perform this
adjustment exactly.
However, this gain has a margin, so even if it is slightly off, there is
no problem. Therefore, do not perform this adjustment.
Focus/tracking gain determines the pick-up follow-up (vertical and
horizontal) relative to mechanical noise and mechanical shock when
the 2-axis device operate.
However, as these reciprocate, the adjustment is at the point where
both are satisfied.
• When gain is raised, the noise when the 2-axis device operates
adjustment exactly.
However, this gain has a margin, so even if it is slightly off, there is
no problem. Therefore, do not perform this adjustment.
Focus/tracking gain determines the pick-up follow-up (vertical and
horizontal) relative to mechanical noise and mechanical shock when
the 2-axis device operate.
However, as these reciprocate, the adjustment is at the point where
both are satisfied.
• When gain is raised, the noise when the 2-axis device operates
increases.
• When gain is lowered, mechanical shock and skipping occurs more
easily.
• When gain adjustment is off, the symptoms below appear.
Gain
Focus
Tracking
Symptoms
• The time until music starts becomes
longer for
p
→
^ on automatic
selection.
low
low or high
(
=, + buttons pressed.)
(Normally takes about 2 seconds.)
• Music does not start and disc
–
low
continues to rotate for
p
→
^ or
automatic selection.
(
(
=, + buttons pressed.)
• Sound is interrupted during PLAY.
Or time counter display stops
–
low
progressing.
• More noise during 2-axis device
high
high
operation.
+
–
–
CD MAIN board
TP (RF)
TP (VC)
Oscilloscope
(DC range)
1. Put the set into test mode.
2. Connect oscilloscope between TP (RF) and TP (VC).
3. Press
2. Connect oscilloscope between TP (RF) and TP (VC).
3. Press
+ and = buttons to move the optical pick-up to the
center. (Move the optical pick-up to the music area on the disc
to enable easy visibility of the eye pattern.)
to enable easy visibility of the eye pattern.)
4. Insert disc (YEDS-18) in and press
^ button.
5. Press the
^ button. (Tracking Servo ON)
6. Adjust RV701 so that the oscilloscope waveform is as shown in
the figure below. (eye pattern)
A good eye pattern means that the diamond shape (≈) in the
center of the waveform can be clearly distinguished.
A good eye pattern means that the diamond shape (≈) in the
center of the waveform can be clearly distinguished.
7. Release test mode after adjustment is completed.
• RF signal reference waveform (eye pattern)
VOLT/DIV : 0.2 V
TIME/DIV : 500 nS
TIME/DIV : 500 nS
1.4
±
0.3 Vp-p
When observing the eye pattern, set the oscilloscope for AC
range and raise vertical sensitivity.
range and raise vertical sensitivity.
Adjustment Location: CD MAIN board (See page 24.)
– 23 –
high tracking gain
high fandamental wave
than for low gain
high fandamental wave
than for low gain
The following is a simple adjustment method.
– Simple Adjustment –
Note:
Note:
Since exact adjustment cannot be performed, remember the
positions of the controls before performing the adjustment.
If the positions after the primary adjustment are only a little
different, return the controls to the original position.
positions of the controls before performing the adjustment.
If the positions after the primary adjustment are only a little
different, return the controls to the original position.
7. Connect oscilloscope to TP (TRACKING-Y) and TP (VC).
8. Adjust RV704 so that the waveform is as shown in the figure
8. Adjust RV704 so that the waveform is as shown in the figure
below. (tracking gain adjustment)
9. Release test mode after adjustment is completed.
+
–
–
TP (FOCUS-Y)
TP (TRACKING-Y)
TP (VC)
oscillosope
(DC range)
(DC range)
CD MAIN board
Procedure:
1. Keep the set horizontal.
1. Keep the set horizontal.
If the set is not horizontal, this adjustment cannot be performed
due to the gravity against the 2-axis device.
due to the gravity against the 2-axis device.
2. Put the set into test mode.
3. Connect oscilloscope to TP (FOCUS-Y) and TP (VC).
4. Insert disc (YEDS-18) in and press
3. Connect oscilloscope to TP (FOCUS-Y) and TP (VC).
4. Insert disc (YEDS-18) in and press
^ button.
5. Press the
^ button. (Tracking Servo ON)
6. Adjust RV702 so that the waveform is as shown in the figure
below. (Focus gain adjustment)
100 mV
0 V
• Inconnect Examples (DC level changes more than on adjusted
waveform)
low focus gain
0 V
250 mV
high focus gain
VOLT/DIV: 100 mV
TIME/DIV:2ms
TIME/DIV:2ms
VOLT/DIV: 100 mV
TIME/DIV:2ms
TIME/DIV:2ms
VOLT/DIV: 100 mV
TIME/DIV:2ms
TIME/DIV:2ms
100 mV
75 mV
75 mV
0 V
VOLT/DIV: 1 V
TIME/DIV:2 ms
TIME/DIV:2 ms
0 V
• Incorrect Examples (fundamental wave appears)
low tracking gain
VOLT/DIV: 1 V
TIME/DIV: 2ms
TIME/DIV: 2ms
0 V
0 V
VOLT/DIV: 1 V
TIME/DIV: 2ms
TIME/DIV: 2ms
– 24 –
Adjustment Location:
RV702
FOCUS GAIN
RV704
TRACKING
GAIN
RV703
E-F BALANCE
RV701
FOCUS BIAS
CNP706
IC701
25
24
13
12
48
1
36
37
[CD MAIN BOARD] (Component Side)
[CD MAIN BOARD] (Conductor Side)
TP (VC)
TP (RF)
TP (TRACKING-Y)
TP (FOCUS-Y)
Click on the first or last page to see other CFD-503 / CFD-505 service manuals if exist.