– 21 –
CD SECTION
Notes on Adjustment
1. Perform adjustment in test mode.
After adjustments, be sure to release test mode.
2. Perform adjustments in the order given.
3. Use the disc (YEDS-18. Part No. 3-702-101-01) only when so
indicated.
Before Adjustment
Put the set into test mode and perform the following checks.
Repair if there are any problems.
• Sled Motor Check
1. Press 
^ button, then press p button.
2. Press 
+, = buttons and confirm that the optical pick-up
moves smoothly from the innermost to outermost circumfer-
ence and back smoothly and with no catching or abnormal noises.
+ : Optical pick-up moves to the outer circumference
= : Optical pick-up moves to the inner circumference
• Focus Search Check
1. Press 
^ button. (Focus serch operation is performed continu-
ously.)
2. Look at the optical pick-up objective lens and confirm that it
moves up and down smoothly, when no catching or abnormal
noises.
3. Press 
p button.
Confirm that focus search operation stops. If it does not , press
p button again longer.
How to Put the Set into Test Mode
1. Short-circuit following portion on the CONTROL board.
2. Turn the FUNCTION selector to CD position.
[CONTROL BOARD] (Conductor Side)
E-F Balance Adjustment
This adjustment is to be done when the optical pick-up block is
replaced.
Procedure:
+
CD MAIN board
TP (Tracking-Y)
TP (VC)
Oscilloscope
(DC range)
1. Put the set into test mode.
2. Connect oscilloscope between TP (TRACKING-Y) and TP
(VC).
3. Press 
+ and = buttons to move the optical pick-up to the
center.
4. Insert disc (YEDS-18) in and press 
^ button.
5. Adjust RV703 so that the oscilloscope traverse waveform is sym-
metrical, as shown in the figure below.
6. Release test mode after adjustment is completed.
A
B
0 V
A=B
VOLT/DIV: 0.2 V
TIME/DIV: 1ms
Adjustment value: 0.5 ± 0.2 Vp-p (A + B)
Adjustment Location: CD MAIN board (See page 24.)
How to Release the Test Mode
1. Open the short-circuit to release test mode.
Short-circuit
– 22 –
Focus Bias Adjustment
This adjustment is to be done when the optical pick-up block is
replaced.
Procedure:
REFERENCE
Focus/Tracking Gain Adjustment
A frequency responce analyzer is necessary in order to perform this
adjustment exactly.
However, this gain has a margin, so even if it is slightly off, there is
no problem. Therefore, do not perform this adjustment.
Focus/tracking gain determines the pick-up follow-up (vertical and
horizontal) relative to mechanical noise and mechanical shock when
the 2-axis device operate.
However, as these reciprocate, the adjustment is at the point where
both are satisfied.
• When gain is raised, the noise when the 2-axis device operates
increases.
• When gain is lowered, mechanical shock and skipping occurs more
easily.
• When gain adjustment is off, the symptoms below appear.
Gain
Focus
Tracking
Symptoms
• The time until music starts becomes
longer for 
p
^ on automatic
selection.
low
low or high
(
=, + buttons pressed.)
(Normally takes about 2 seconds.)
• Music does not start and disc
low
continues to rotate for 
p
^ or
automatic selection.
(
=, + buttons pressed.)
• Sound is interrupted during PLAY.
Or time counter display stops
low
progressing.
• More noise during 2-axis device
high
high
operation.
+
CD MAIN board
TP (RF)
TP (VC)
Oscilloscope
(DC range)
1. Put the set into test mode.
2. Connect oscilloscope between TP (RF) and TP (VC).
3. Press 
+ and = buttons to move the optical pick-up to the
center. (Move the optical pick-up to the music area on the disc
to enable easy visibility of the eye pattern.)
4. Insert disc (YEDS-18) in and press 
^ button.
5. Press the 
^ button. (Tracking Servo ON)
6. Adjust RV701 so that the oscilloscope waveform is as shown in
the figure below. (eye pattern)
A good eye pattern means that the diamond shape (≈) in the
center of the waveform can be clearly distinguished.
7. Release test mode after adjustment is completed.
• RF signal reference waveform (eye pattern)
VOLT/DIV : 0.2 V
TIME/DIV  : 500 nS
1.4 
±
 0.3 Vp-p
When observing the eye pattern, set the oscilloscope for AC
range and raise vertical sensitivity.
Adjustment Location: CD MAIN board (See page 24.)
– 23 –
high tracking gain
high fandamental wave
than for low gain
The following is a simple adjustment method.
– Simple Adjustment –
Note:
Since exact adjustment cannot be performed, remember the
positions of the controls before performing the adjustment.
If the positions after the primary adjustment are only a little
different, return the controls to the original position.
7. Connect oscilloscope to TP (TRACKING-Y) and TP (VC).
8. Adjust RV704 so that the waveform is as shown in the figure
below. (tracking gain adjustment)
9. Release test mode after adjustment is completed.
+
TP (FOCUS-Y)
TP (TRACKING-Y)
TP (VC)
oscillosope
(DC range)
CD MAIN board
Procedure:
1. Keep the set horizontal.
If the set is not horizontal, this adjustment cannot be performed
due to the gravity against the 2-axis device.
2. Put the set into test mode.
3. Connect oscilloscope to TP (FOCUS-Y) and TP (VC).
4. Insert disc (YEDS-18) in and press 
^ button.
5. Press the 
^ button. (Tracking Servo ON)
6. Adjust RV702 so that the waveform is as shown in the figure
below. (Focus gain adjustment)
100 mV
0 V
• Inconnect Examples (DC level changes more than on adjusted
waveform)
low focus gain
0 V
250 mV
high focus gain
VOLT/DIV: 100 mV
TIME/DIV:2ms
VOLT/DIV: 100 mV
TIME/DIV:2ms
VOLT/DIV: 100 mV
TIME/DIV:2ms
100 mV
75 mV
0 V
VOLT/DIV: 1 V
TIME/DIV:2 ms
0 V
• Incorrect Examples (fundamental wave appears)
low tracking gain
VOLT/DIV: 1 V
TIME/DIV: 2ms
0 V
0 V
VOLT/DIV: 1 V
TIME/DIV: 2ms
– 24 –
Adjustment Location:
RV702
FOCUS GAIN
RV704
TRACKING
GAIN
RV703
E-F BALANCE
RV701
FOCUS BIAS
CNP706
IC701
25
24
13
12
48
1
36
37
[CD MAIN BOARD] (Component Side)
[CD MAIN BOARD] (Conductor Side)
TP (VC)
TP (RF)
TP (TRACKING-Y)
TP (FOCUS-Y)