– 17 –
4-3. CD SECTION
Notes on Adjustment
1. Perform Traverse adjustment in test mode.
After adjustment, be sure to release test mode.
2. Perform adjustments in the order given.
3. Use the disc (YEDS-18, Part No. 3-702-101-01) only when so
indicated.
4. Short the both sides of R720 on the CD board for stop operation of
anti-shock circuit. (See page 20.)
• Switch position
FUNCTION switch : CD
• In case of Test Mode
1. Short the solder bridge the TP (TEST) on the CONTROL board.
2. Insert the AC power plug.
• Release the Test Mode
  Release the shorted solder bridge the TP (TEST), the test mode is
  release.
Before Adjustment
Put the set into test mode and perform the following checks. Repair
if there are any problems.
• Sled Motor Check
Press the 
±, ≠ buttons and confirm that the optical pick-up
moves smoothly from the innermost to outermost circumference and
back smoothly and with no catching or abnormal noises.
± : Optical pick-up moves to the outer circumference
≠ : Optical pick-up moves to the inner circumference
• Focus Search Check
1. Push the 
fl button. (Focus search operation is performed
continuously.)
2. Look at the optical pick-up objective lens and confirm the it moves
up and down smoothly, with no catching or abnormal noises.
3. Push the 
π button.
Confirm that focus search operation stops. If it does not, push the
π button again longer.
Traverse Adjustment
This adjustment is to be done when the optical pick-up block is
replaced.
Procedure:
1. Connect the oscilloscope between TP (TE) and TP (VC).
2. Put the set into test mode.
3. Push the CD lid to open and insert disc (YEDS-18).
4. Close the CD lid.
5. Press the 
± and ≠ buttons to move the optical pick-up to
the center.
6. Push the 
fl button.
7. Push the 
π button.
8. Push the 
fl button.
9. Adjust RV703 so that the oscilloscope traverse waveform is
symmetrical, as shown in the figure below.
10. Release test mode after adjustment is completed.
–control board (conductor side) –
IC801
25
24
TP
(TEST)
oscilloscope
(DC range)
CD board
TP (TE)(IC701 
)
TP (VC)(IC701 
$•
)
Adjustment Location : See page 20.
0V
A=B
A
B
– 18 –
• The time until music starts becomes longer
for 
π m fl on automatic selection.
(
≠, ± buttons pressed.)
(Normally, takes about 2 seconds.)
• Music does not start and disc continues
to rotate for 
π m fl or automatic
selection.
(
≠, ± buttons pressed.)
• Sound is interrupted during PLAY. Or
time counter display stops progressing.
• More noise during 2-axis device
operation.
Focus Bias Adjustment
This adjustment is to be done when the optical pick-up block is
replaced.
Procedure :
1. Connect the oscilloscope between TP (RF) and TP (VC).
2. Insert disc (YEDS-18) and push the 
fl button.
3. Adjust RV701 so that the oscilloscope waveform is maximum as
shown in the figure below (eye pattern).
• RF signal reference waveform (eye pattern)
  REFERENCE
Focus/Tracking Gain Adjustment
A frequency response analyzer is necessary in order to perform this
adjustment exactly.
However, this gain has a margin, so even if it is slightly off, there is
no problem. Therefore, do not perform this adjustment.
Focus/tracking gain determines the pick-up follow-up (vertical and
horizontal) relative to mechanical noise and mechanical shock when
the 2-axis device operate.
However, as these reciprocate, the adjustment is at the point where
both are satisfied.
• When gain raised, the noise when the 2-axis device operates
increases.
• When gain is lowered, it is more susceptible to machanical shock
and skipping occurs more easily.
When gain adjustment is off, the symptoms below appear.
oscilloscope
(DC range)
CD board
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
Adjustment Location : See page 20.
Symptoms
Gain
Focus
Tracking
low
low or high
low
low
high
TP (RF)(IC702 
)
TP (VC)(IC701 
$•
)
0V
1.3 ± 0.2 V
VOLT / DIV : 0.2 V
TIME / DIV : 500 nS
high
– 19 –
The following is a simple adjustment method.
–Simple Adjustment–
Note :
Since exact adjustment cannot be performed, remember the
positions of the controls before performing the adjustment.
If the positions after the simple adjustment are only a little
different, return the controls to the original position.
Procedure:
1. Keep the set horizontal.
If the set not horizontal, this adjustment cannot be performed due
to the gravity against the 2-axis device.
2. Insert disc (YEDS-18) and push the 
fl button.
3. Connect the oscilloscope between TP  (FE) and TP (VC).
4. Adjustment RV702 so that the waveform is as shown in the figure
below. (focus gain adjustment)
• Correct Example
5. Connect the osilloscope between TP (TE) and TP (VC).
6. Adjust RV704 so that the waveform is as shown in the figure below.
(tracking gain adjustment)
• Correct Example
oscilloscope
(DC range)
CD board
TP (FE)(IC701 
1
)
TP (TE)(IC701 
)
TP (VC)(IC701 
$•
)
• Incorrect Examples (DC level changes more than on adjusted
  waveform)
VOLT/DIV : 100 mV
TIME/DIV : 2 mS
0 V
100 mV
0 V
250 mV
VOLT/DIV : 100 mV
TIME/DIV : 2 mS
VOLT/DIV : 100 mV
TIME/DIV : 2 mS
0 V
75 mV
100 mV
• Incorrect Examples (fundamental wave appears)
VOLT/DIV : 100 mV
TIME/DIV : 2 mS
0 V
VOLT/DIV : 100 mV
TIME/DIV : 2 mS
0 V
0 V
VOLT/DIV : 100 mV
TIME/DIV : 2 mS
Adjustment Location : See page 20.
low focus gain
high focus gain
low tracking gain
high tracking gain
(higher fundamental wave than for low gain)
– 20 –
Adjustment Location : CD board (conductor side)
TRACKING GAIN
ADJ
RV704
FOCUS GAIN
ADJ
RV702
TRAVERSE
ADJ
RV703
FOCUS BIAS
ADJ
RV701
TP
(FE)
TP
(VC)
TP
(TE)
R720
IC701
TP
(RF)
Page of 37