— 5 —
SECTION  3
DISASSEMBLY
Note :
 Follow the disassembly procedure in the numerical order given.
3-1. FRONT PANEL ASSEMBLY
1
Push the part A in the direction of arrow to
remove the loading panel upward.
A part
6
Two screws
(BVTP2.6x8)
8
Panel bracket
4
Connector
(CN751)
Claw
3
Screw (BVTP3x8)
(AEP, G only)
2
Three screws
(BVTP3x8)
5
Connector (CN302)
(Flat type 23 core)
Claw
7
Wire
9
Remove the front panel assembly
with care to claws.
— 6 —
When the 
p button is pressed, the following will be displayed.
(partial lighting 2)
When the OPEN/CLOSE 
§ button is pressed, all will light up
again.
• Key check
All buttons have corresponding button numbers. When a button is
pressed, the counter will count up and display the button’s num-
ber. However, the counter will only count to “17”. It will not count
for buttons already pressed once, but will display the button’s
number.
SECTION 4
TEST MODE
4-1. AF MODE
The following checks can be performed in the AF mode, which is set
by connecting the TP2 (AFADJ) terminal on MAIN board to the
Ground and turning on the power.
• FL tube check
After all segments light up, when the 
· button is pressed, the
following will be displayed. (Partial lighting 1)
2
4
6
8
10
12
14
16
18
20
(Partial lighting 2)
(Partial lighting 1)
8
 
8 8 8
• Remote commander check
When the 
· button of the remote commander is pressed, the
·” lights up. All go off when the other buttons are pressed.
• Audio check
• Initial setting of digital filter and release of mute.
• When the TP2 (AFADJ) terminal on MAIN board is set to HIGH
(VDD), emphasis turns on. When set to LOW (Ground), it turns
off.
TIME
FADER
REPEAT
PLAY MODE
EDIT/
TIME FADE
PEAK SEARCH
AUTO SPACE
MUSIC SCAN
P
00
01
02
03
ENTER
CLEAR
CHECK
)
0
OPEN/
CLOSE 
§
PLAY 
·
STOP 
p
32
33
34
35
36
04
05
06
07
25
Button
Button No.
Displayed
Button
Button No.
Displayed
88
8888
88
Â
Display of counting
Â
Display of button number
All lit
Partial lighting 1
Partial lighting 2
— 7 —
4-2. ADJ MODE
The following operations are performed in the ADJ mode, which
is set by connecting the TP1 (ADJ) terminal to the Ground and
turning on the power.
• During playback, there is no problem even if the GFS is continu-
ously LOW.
• High speed search is prohibited during access.
• During playback, the gain of focus servo and spindle servo does
not decrease.
• Servo related manual operations and measurement can be
performed.
(For details of operations, refer to Table of Key Operrations in ADJ
Mode.)
4-3. CLV-S MODE
The spindle servo for playback sets into the CLV-S mode when
the TP1 (ADJ) terminal is connected to Ground after turning on the
power.
TABLE OF BUTTON OPERATIONS IN ADJ MODE
The jitter value display mode can be set after the all-music
remaining number mode using the TIME button.
The functions of the number buttons are shown in the following
table.
FUNCTIONS OF NUMBER BUTTONS
(With the attached remote commander)
[ MAIN BOARD ] — Component Side —
CN302
IC920
TP1 (ADJ)
TP2 (AFADJ)
CN301
1
2
3
4
5
6
7
8
10
Focus bias 8-step up
Middle of focus bias up/down turning point
Tracking servo, sled servo off
Auto gain initialization
Focus servo off
Focus bias 8-step down
Immediate readjustment of focus bias
Tracking servo, sled servo on
Auto focus bias start point
Function
Button
— 8 —
SECTION 5
ELECTRICAL BLOCK CHECKING
Note:
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent when
the signal level is low than specified value with the following
checks.
S Curve Check
Procedure :
1. Connect oscilloscope to test point TP (FE) on BD board.
2. Connect between test point TP (FEI) and TP (VC) by lead wire.
3. Turned Power switch on.
4. Put disc (YEDS-18) in and turned Power switch on again and
actuate the focus search. (actuate the focus search when disc table
is moving in and out.)
5. Check the oscilloscope waveform (S-curve) is symmetrical
between A and B. And confirm peak to peak level within 3±1
Vp-p.
S-curve waveform
6. After check, remove the lead wire connected in step 2.
Note : • Try to measure several times to make sure than the ratio of
A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF Level Check
Procedure :
1. Connect oscilloscope to test point TP (RF) on BD board.
2. Turned Power switch on.
3. Put disc (YEDS-18) in to play the number five track.
4. Confirm that oscilloscope waveform is clear and check RF signal
level is correct or not.
Note: A clear RF signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
RF signal waveform
E-F Balance (1 Track Jump) Check
(Without remote commander)
Procedure :
1. Connect oscilloscpe to test point TP (TE) on BD board.
2. Turned Power switch on.
3. Put disc (YEDS-18) in to play the number five track.
4. Press the “
P (Pause)” button. (Becomes the 1 track jump mode)
5. Check the level B of the oscilliscope's waveform and the A (DC
voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
1 track jump waveform
E-F Balance Check (With remote commander)
Procedure :
1. Connect the test point TP1 (ADJ) on MAIN board to the ground
with a lead wire on main board.
2. Connect oscilloscpe to test point TP (TE) on BD board.
3. Turn the Power switch on to set the ADJ mode.
4. Put disc (YEDS-18) in to play the number five track.
5. Press the “3” button. (The tracking servo and the sledding servo
are turned OFF.)
oscilloscope
BD board
TP (FE)
TP (VC)
symmetry
A
B
within 3 ± 1 Vp-p
BD board
TP (RF)
TP (VC)
oscilloscope
level : 1.3           Vp-p
VOLT/DIV : 200mV
TIME/DIV : 500ns
+0.25
–0.20
oscilloscope
BD board
TP (TE)
TP (VC)
Center of the waveform
0V
B
level : 1.3 ± 0.6 Vp-p
symmetry
A (DC voltage)
oscilloscope
BD board
TP (TE)
TP (VC)