— 9 —
3-3. BASE UNIT
1
Connectors
(CN201, CN210: SERVO board)
2
Screw (B 3X8)
3
Ground wire
4
Four screws (B 2.6X6)
5
Boss (M) (Four pieces)
6
Base unit
Spring
3-4. BACK PANEL
1
Connectors
(CN305: A OUT board)
(CN502: CN508, CN509, CN512: AUDIO board)
2
Screw (B 3X8)
3
Ground wire
4
Two screws (B 3X6)
6
Back panel assembly
5
Three screws (BV 3X8)
— 10 —
SECTION 4
ELECTRICAL BLOCK ADJUSTMENTS
Note:
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent when
the signal level is low than specified value with the following
checks.
S Curve Check
Procedure :
1. Connect oscilloscope to test point TP (FE: CN210 !ºpin).
2. Connect between test point TP (FEI: IC101 @ªpin) and TP (VC:
CN210 !™pin) by lead wire.
3. Put disc (YEDS-18) in and turn Power switch on and actuate the
focus search.
4. Check the oscilloscope waveform (S-curve) is symmetrical be-
tween A and B. And confirm peak to peak level within 3±1 Vp-p.
S-curve waveform
5. After check, remove the lead wire connected in step 2.
Note : • Try to measure several times to make sure than the ratio of
A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the bright-
ness to obtain best waveform.
RF Level Check
Procedure :
1. Connect oscilloscope to test point TP (RF:CN215 1pin).
2. Turn Power switch on.
3. Put disc (YEDS-18) in and playback.
4. Confirm that oscilloscope waveform is clear and check RF signal
level is correct or not.
Note: A clear RF signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
RF signal waveform
E-F Balance Check
Procedure :
1. Connect test point TP (ADJ: CN515 3pin) to Ground and TP
(TEI: IC101 @¶pin) to TP (VC: CN210 !™pin) with a lead wire.
2. Connect oscillscope to test point TP (TE: CN210 !¡pin)
3. Turn Power switch on.
4. Put disc (YEDS-18) in and playback.
5. Confirm that the oscilloscope waveform is symmetrical on the
top and bottom in relation to 0Vdc, and check this level.
Traverse waveform
6. Remove the lead wire connected in step 1.
oscilloscope
oscilloscope
level : 1.2           Vp-p
VOLT/DIV : 200mV
TIME/DIV : 500ns
+0.25
–0.20
oscilloscope
SERVO board
symmetry
A
B
level: 3 ± 1 Vp-p
SERVO board
SERVO board
2. Turn Power switch on.
3. Put the disc (YEDS-18) in and playback.
Confirm that reading on frequency counter is 4.3218 MHz.
Setting of Focus/Tracking Auto Gain Data
Refer to “Writing of Focus/Tracking Auto gain data” on page 3.
RF PLL Free-run Frequency Check
Procedure :
1. Connect frequency counter to test point TP (PLK: CN513 4pin)
with lead wire.
frequency counter
TP (PLK)
TP (FE)
TP (VC)
TP (RF)
TP (VC)
TP (TE)
TP (VC)
symmetry
0Vdc
level : 2 ± 1 Vp-p
SERVO board
— 11 —
Skew Adjustment
(Be sure to perform this adjustment when the optical pick-up or a
mechanical part of the optical pick-up has been replaced.)
1. Remove the top plate. (See 3. Disassembly/Top Plate Assembly)
2. Remove the eight screw (+B3X8) of the top plate and remove the
KEY board.
3. Connect the KEY board connector and the DISPLAY board con-
nector.
4. Remove the base unit. (Do not disconnect the connectors.)
(Refer to 3. Disassembly/Base Unit.)
5. Adjust with the unit placed sideways as shown in the figure.
6. Connect and oscilloscope to TP (RF: 1Pin of CN215).
7. While pressing the 
±and ·buttons, press the POWER but-
ton. (The discrete open/close detection is turned OFF.)
8. Set a disk (YEDS-18) and press the 
·button.
9. Rotate the adjustment screw with a Phillips screwdriver and ad-
just so that the oscilloscope waveform becomes clear.
Note: A clear RF signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
RF signal waveform
level : 1.2           Vp-p
VOLT/DIV : 200mV
TIME/DIV : 500ns
+0.25
–0.20
Adjustment
screw
Base unit
KEY BOARD
10.After the adjustment, lock the adjustment screw.
[ SERVO BOARD ] — Conductor Side —
CN514
CN513
(ADJ)
(PLK)
CN515
IC101
CN215
CN210
6      4          1
3      1
(RF)
(FE)
(VC)
(TE)
29 (FEI)
27 (TEI)
1
12
10
2
11
1
Note: Hold the base
unit horizontally.
— 12 —
SECTION  5
DIAGRAMS
5-1. CIRCUIT BOARDS LOCATION
AC IN board
B OUT board
BSL board
AC SW board
DISPLAY board
AUDIO board
KEY board
S POWER board
OUT SW board
OPTICAL board
FLEXIBLE board
SERVO board
A OUT board
U OUT board
Page of 30