DOWNLOAD Sony CDP-M333ES / CDP-M555ES Service Manual ↓ Size: 6.79 MB | Pages: 70 in PDF or view online for FREE

Model
CDP-M333ES CDP-M555ES
Pages
70
Size
6.79 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
cdp-m333es-cdp-m555es.pdf
Date

Sony CDP-M333ES / CDP-M555ES Service Manual ▷ View online

13
AGING PROCEDURE
1.
Turn on the power and press the  GROUP FILE ,  MEGA CTRL
and  
I
/
1
  buttons.
2.
Rotate  DISC/CHARACTER  knob, select “Normal Aging”
and press the button to start the aging mode.
3.
When the disc set mode is set, the  
H
  and  
X
  LEDs blink.
4.
Rotate the  DISC/CHARACTER  knob. The slits (No. 80, 160,
400, 240, 320) for setting the discs will come forward. Insert
the discs into these slits. Do not set the discs in other slits.
5.
Set whether the self-protection function during errors is
equipped with the unit. Press the  REPEAT  button. If
“REPEAT” is displayed on the fluorescent indicator tube, it
means the function is provided. If “REPEAT” is not displayed,
it means the function is not provided.
6.
Press the 
H
 button.
7.
The  
H
  LED blinks, the aging mode is set, and aging is started.
8.
The aging cycle lasts 3 minutes. If errors occur during aging,
the error number will be displayed on the fluorescent indicator
tube. (Refer to the following table for the details of the errors.)
9. Aging will be repeated as long as no errors occur.
10. After each aging cycle, the number displayed on the Fluorescent
indicator tube will increase.
11. To end aging, to end aging, press the  
I
/
1
  button to enter the
standby mode.
Contents
Code number
Name
Error code
The * numbers mean the following according to the state of the unit during aging
2 : From chucking to end of TOC read
3 : From end of TOC read to end of last track playback
4 : From end of last track playback to end of first track playback
# : DISC No.
SPECIAL AGING MODE FUNCTIONS
The aging mode is provided with the following convenient func-
tions
• Disc setting mode (*1)
• Selection of presence of protection function during error (*2)
• Count function of aging cycle (*3)
*1 Disc setting mode:
5 discs are set before setting the aging mode. This mode makes
the setting of these discs more easy.
*2 Self protection function during errors:
Function which voluntarily corrects errors which occur during
normal operations by retries.
If this function is not provided, all operations will be stopped
without retiring. It is suitable for checking errors with low
reproducibility.
If this function is provided, and errors can be corrected by
retries, aging will be continued without stopping.
*3 Aging cycle count function:
Functions which displays the number of agings carried out on
the Fluorescent indicator tube  in numbers. One aging cycle
consists of five discs.
#Err 01
#Err 02
#Err 03
#Err 04
#Err 05
#Err 06
#Err 08
#Err 09
#Err *1
#Err *2
#Err *3
#Err *4
#Err *5
#Err *6
DISC sensor check 1
DISC sensor check 2
Table operation check 1
Table operation check 2
Loading operation check 1
Loading operation check 2
Table stop precision check 1
Table stop precision check 2
BU related check 1
BU related check 2
BU related check 3
BU related check 4
BU related check 5
BU related check 6
No disc in the specified slit
Disc in other slits
Table motor current over
No table sensor input
Load in timeover
Load out timeover
Table is not stopped within the specified time.
Stopped while both T.SENS 1 and 2 are “LOW”.
Access timeover
During high speed playback, COUNT timeout
Q data read error
]BU operation (from focus search to until signal can be read) timeover
GFS monitor error
Focus cannot be imposed by focus search
14
for checking the microprocessor model setting, etc.
Procedure:
With the power ON, while pressing the  GROUP FILE  and MEGA
CTRL buttons, press the 
I
/
1
  button.
Rotate the  DISC/CHARACTER  knob, select “Model Name”
and press the dial.
The model name is displayed on the fluorescent indicator tube.
Let the model name be displayed for three seconds and exit the
mode.
MICROPROCESSOR VERSION DISPLAY
• The microprocessor version can be displayed on the fluorescent
indicator tube.
Procedure:
With the power ON, while pressing the  GROUP FILE  and MEGA
CTRL  buttons, press the  
I
/
1
  button.
Rotate the  DISC/CHARACTER  knob, select “Show Mcom Ver.”
and press the dial.
The microprocessor version is displayed on the fluorescent indi-
cator tube.
Let the model name be displayed for three seconds and exit the
mode.
LOADING AGING MODE
• This mode is used for repeating loading operations continuously.
• Aging will be performed continuously unless an error occurs.
• When an error occurs, the error code will be displayed on the
fluorescent indicator tube.
Procedure:
1.
Set a disc in the DISC 1 slit.
2.
Turn on the power and press the  GROUP FILE ,  MEGA CTRL
and  
I
/
1
  buttons.
Rotate the  DISC/CHARACTER  knob, select “Table
Roatation” and press the dial.
3.
When the mode is set, both the  
H
   and  
X
   indicators will
start to blink.
4.
When the  
H
   button is pressed, only the  
H
   indicator will
blink and aging starts.
5.
To end the mode, press the  
I
/
1
   button or disconnect the
power cord from the outlet.
The error codes displayed during operations and when errors oc-
cur are the same as the 
“AGING MODE”
 described earlier.
TABLE AGING MODE
• This mode is used for rotating the table randomly.
• Aging will be performed continuously unless an error occurs.
• When an error occurs, the error code will be displayed on the
fluorescent indicator tube.
Procedure:
1.
Turn on the power and press the  GROUP FILE ,  MEGA CTRL
and 
I
/
1
 buttons.
Rotate the  DISC/CHARACTER  knob, select “Table Aging”
and press the dial.
Rotate the  DISC/CHARACTER  knob and set the disk in the
slit whose number is being displayed (150, 149, 300, 1, 2)
2.
When the mode is set, both the  
H
   and  
X
   indicators will
start to blink.
3.
When the  
H
   button is pressed, only the  
H
   indicator will
blink and aging starts.
4.
To end the mode, press the  
I
/
1
   button or disconnect the
power cord from the outlet.
During aging, operations will be carried out sequentially in the
order of No. 1, No. 2, No. 150, No. 149, and No. 300 slits.
The error codes displayed during operations and when errors oc-
cur are the same as the 
“AGING MODE”
 described earlier.
DOOR POP UP AGING MODE
• This mode is used for performing aging of the CD pop up part
and door open/close.
It is used for checking if operations are performed normally.
Method:
1.
Turn on the power and press the  GROUP FILE ,  MEGA CTRL
and  
I
/
1
  buttons.
Rotate the  DISC/CHARACTER  knob, select “Door Popup
Aging” and press the dial.
2.
Aging starts, and door open/close and up/down operations of
the pop up part are performed continuously.
3.
To end the mode, press the  
I
/
1
  button.
TABLE ROTATION MODE
• This mode is used for electrical adjustments. Refer to the sec-
tion on Electrical Adjustments.
TITLE MEMO SHIFT MODE
• This mode is used for writing title memo information recorded
in this unit in a different unit.
Use it for transferring disc memo contents written by the cus-
tomer to the new units when replacing the unit, etc.
Connection:
CONTROL A1 
II
 connection cord provided
Flow of data
This unit
(Copy source)
Another unit
(Copy destination)
CONTROL A1 
II
Procedure:
1.
Connect two units using the  CONTROL A1 II  connection
cord shown in the figure.
2.
With the power on, while pressing the  GROUP 7  button and
OPEN/CLOSE  button of the copy destination unit, press the
+100  button.
3.
When the data has been transferred, the fluorescent indicator
tube displays “complete” for about 1 second.
MODEL NAME DISPLAY
• Model names can be displayed on the fluorescent indicator tube
r
r
r
r
15
ALL LIT MODE
• This mode is used for lighting the whole fluorescent indicator
tubes and LEDs.
Procedure:
With the power ON, while pressing the  GROUP FILE  and  MEGA
CTRL buttons, press the 
I
/
1
  button.
Rotate the  DISC/CHARACTER  knob, select “All Lit Mode” and
press the dial.
Both the fluorescent indicator tubes and LEDs will light up com-
pletely.
To end this mode, press the  
I
/
1
  mode.
MECHANISM ADJUSTMENT MODE
• This mode is used for mechanism adjustments. Refer to the sec-
tion on Mechanism Adjustments.
SHIPMENT MODE
• This mode is used for setting the unit to the shipment state.
Do not execute it without a proper reason as it erases the memory
of the title memo recorded by the customer.
Procedure:
Set the TIMER switch to OFF . Next, with the power ON, while
pressing the  GROUP FILE  button and MEGA CTRL button,
press the  
I
/
1
  button. If the switch state is normal, the model
name will be displayed on the fluorescent indicator tube and the
unit will set into the shipment mode.
If the various switches are not set to their designated positions,
error  will be displayed on the fluorescent indicator tube.
TITLE MEMO RECORDING CHECK MODE
This mode is not required for servicing. Do not execute without a
proper reason.
If executed, the memory of the title memo recorded by the cus-
tomer will be erased.
16
SECTION  5
TEST  MODE
ADJ MODE
1. Turn ON the power of the unit, set disc to disc table, and per-
form chucking.
2. Remove the power cord from the outlet.
3. To set ADJ mode, connect the TP4 (ADJ) of the MAIN board
to ground, and connect the power cord to the outlet.
In this mode, table rotation and loading operations are not per-
formed because it is taken that the disc has already been chucked.
Note:
The same operations are also performed in the following when the
TP4 (ADJ) is connected to ground after turning on the power.
• Direct search (movement of sledding motor) is not performed dur-
ing accessing
• Ignored even when GFS becomes L
• Ignored even when the Q data cannot be read
• Focus gain does not decrease
ADJ Mode Special Functions Table
KEY  AND  DISPLAY  CHECK  MODE
To set this mode, connect the TP5 (AFADJ) on the MAIN board to
ground, and connect the power cord to the outlet.
Note:
When this mode is executed, all title memos recorded will be erased.
• When this button is pressed, “line # No. #” will be displayed. However,
these will not be displayed for the following special buttons. However,
these will not be displayed for the following special buttons.
 
x
(stop) button
: FL segment check
(Refer to FL Tube Check Patterns)
 
X
(pause) button : FL grid check
(Refer to FL Tube Check Patterns)
The  
X
  LED also lights up simulta-
neously.
 
H
  (play) button : All FL segment and grid will light up.
H
LED also lights up simultaneously.
TIMER switch
: When the switch position is
[PLAY]
, the
[STANDBY]
 LED lights up. It goes OFF
when set to
[OFF]
.
Each time this button is pressed, the value of the “Go+ ## keys”
increases. Buttons pressed once will not be counted when pressed
again.
FL Tube Check Patterns
Segment check
Grid check
• When the jog dial is rotated to the right, the GROUP LEDs light
up in the order of 1
t2..8tHIT LISTtEASY
PLAY
tARTIST MODEtMEGA CTRLt1.
• When the jog dial is rotated to the left, the GROUP LEDs light
up in the order of 8
t7..1tMEGA CTRLtARTIST
MODE
tEASY PLAYtHIT LISTt8.
• Abbreviation
  FL: Fluorescent Indicator Tube
Button
CONTINUE
SHUFFLE
PROGRAM
GROUP 3 (3)
GROUP 8 (8)
CHECK
Function
Servo average display
Displays VC, FE, RF, TE and traverse in hexadeci-
mal numbers
Focus bias display
Each time this is pressed, the focus bias is
switched between 1 and 2
(1)
Bias actually set     Optimum bias     Minimum jitter
(2)
U:Upper aliasing bias     L:Lower aliasing bias
Auto gain display
Displays focus, tracking, sledding in
hexadecimal numbers
Turns off the tracking and sledding servo
Turns on the tracking and sledding servo
S-curve observation mode.
(Release this mode when the
I
/
1
button is pressed.)
IC501
GND
TP4(ADJ)
TP5
(AFADJ)
Magnified
A    B    C    D    E    F    G
• Checking Location
– MAIN BOARD (Conductor Side) –
Page of 70
Display

Click on the first or last page to see other CDP-M333ES / CDP-M555ES service manuals if exist.