DOWNLOAD Sony CDP-D500 Service Manual ↓ Size: 905.67 KB | Pages: 36 in PDF or view online for FREE

Model
CDP-D500
Pages
36
Size
905.67 KB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
cdp-d500.pdf
Date

Sony CDP-D500 Service Manual ▷ View online

– 13 –
Note:
 
Follow the disassembly procedure in the numerical order given.
CASE
SECTION  3
DISASSEMBLY
LOADING  PANEL
1
Insert a tarpering driver into the
aperture of the unit bottom,
and turn to the direction of arrow.
1
three screws
(M3 
×
 10)
2
case
1
three screws
(M3 
×
 10)
1
three screws
(M3 
×
 10)
1
two screws
(M3 
×
 10)
3
two screws
(BVTP3 
×
 10)
4
loading panel
2
Pull the disc table
– 14 –
FRONT  PANEL  SECTION
3
three screws
(BVTT3 
×
 8)
4
front panel
3
four screws
(BVTT3 
×
 8)
2
connector
(CN331)
MECHANISM  DECK
4
mechanism deck
3
four screws
(BVTT3 
×
 8)
1
flat wire (27 core)
(CN501)
1
flat wire (19 core)
(CN401)
2
connector
(CN531)
– 15 –
SECTION  4
TEST  MODE
Key Check
(tact switch)
1) Connect the test point TP (ADJ) on MAIN board to the
ground with a lead wire on MAIN board.
2) Turn on the power with turning OFF the TIMER SW.
“KEY TEST” shall be shown.
3) When the TACT SW is pushed, the order of pushing is shown
on digit 0 and 1.
4) It will count up until 34 which is the maximum key number.
“END” will be shown after 34.
(slide switch)
Words as below shall be shown.
CXD2545  Servo Check
1) Connect the test point TP (ADJ) on MAIN board to the
ground with a lead wire on MAIN board.
2) Turn on the power, tuning ON the TIMER SW.
3) Establish as below articles with the combination of TENKEY
and TIMER SW.
TENKEY
MODE
TIMER SW OFF
3
Tracking servo off
8
Tracking servo on
TIMER SW ON
1
S-cuve observe
OFF
ON
TIMER SW
NULL (not shown)
REPEAT
REMOTE
CONTINUE/
Parallel ON 
 PROGRAM
SELECT SW
PROGRAM
Serial ON 
 CONTINUE
AUTO CUE/
NULL (not shown)
A.CUE ON 
 AUTO CUE
PAUSE SW
A.PAUSE ON 
 AUTO PAUSE
(JOG)
When dial the VARI SPEED JOG/AMS dial, the value on digit
6 and 7 will be clocwise/rev clockwise.
(shuttle)
Is it turns to forward direction, calendar will show 1·2·3 and 4
and if turns to backward direction. Calendar will show 16·17·18
and 19.
EDP Bridge Check
1) Connect the test point TP (ADJ) on MAIN board to the
ground with a lead wire on MAIN board.
2) Turn on the power, with turning ON the TIMER SW.
3) Elements next to digit/segment will turn on and off mutu-
ally.
4) When both sides elements turn on at the same time the grid
is a bridge.
5) When the calendar does not work correctly, segment is a
bridge.
S-RAM Verify Check
1) Connect the test point  TP (ADJ) on MAIN board to the
ground with a lead wire on MAIN board.
2) Turn on the power, with turning ON the TIMER SW and
CUE SW.
3) Address (0x8000~0x9fef) will be written by µ-com on the
digit 5 and 6, and they will be read by µ-com on the digit 8
and 9, then the value shall be shown on the digit 0 to 3.
When the written value do not agree with the read value,
“VERIFY ERROR” will be shown.
After that, it will show the position of address line and the
data line which are cause of S-RAM bridge and a float.
– 16 –
SECTION  5
ELECTRICAL  ADJUSTMENTS
Note:
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the fol-
lowing checks.
S-Curve Check
Note:
Try to measure several times to make sure that the ratio of
A:B or B:A is more than 10:7.
Take sweep time as long as possible and light up the bright-
ness to obtain best waveform.
RF Level Check
Procedure:
1. Connect the test point TP (ADJ) on MAIN board to the ground
with a lead wire on MAIN board.
2. Connect oscilloscope to test point TP (FE) on BSL board.
3. Turned Power switch on to set ADJ mode by TIMER SW OFF.
4. Put disc (YEDS-18) in and turned Power switch on again and
actuate the focus search. (actuate the focus search when disc
table is moving in and out.)
5. TIMER SW ON.
6. Press the “1” button (s-cuve observe mode).
7. Check the oscilloscope waveform (S-curve) is symmetrical be-
tween A and B. And confirm peak to peak level within 3 ± 1 Vp-p.
S-curve waveform
Note: A clear RF signal waveform means that the shape “≈” can
be clearly distinguished at the center of the waveform.
RF signal waveform
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level: 1.2       Vp-p
+0.25
–0.20
E-F Balance (1 Track Jump) Check
E-F Balance Check
+
BSL board
TP (FE)
TP (VC)
oscilloscope
Procedure:
1. Connect oscilloscope to test point TP  (RF) on BSL board.
2. Turned Power switch on.
3. Put disc (YEDS-18) in to play the number five track.
4. Confirm that oscilloscope waveform is clear and check RF sig-
nal level is correct or not.
+
BSL board
TP (RF)
TP (VC)
oscilloscope
+
BSL board
TP (TE)
TP (VC)
oscilloscope
Procedure:
1. Connect the test point TP (ADJ) on MAIN board on the ground
with a lead wire on MAIN board.
2. Connect oscilloscope to test point TP (TE) on BSL board.
3. Turn the Power switch on to set the ADJ mode. (TIMER SW
OFF)
4. Put disc (YEDS-18) in to play the number five track.
5. Press the “3” button. (The tracking servo and the sledding servo
are turned OFF.)
Procedure:
1. Connect oscilloscope to test point TP (TE) on BSL board.
2. Turned Power switch on.
3. Put disc (YEDS-18) in to play the number five track.
4. Press the “
P (Pause)” button. (Becomes the 1 track jump mode)
5. Check the level B of the oscilloscope’s waveform and the A
(DC voltage) of the center of the Travers waveform.
Confirm the following :
A/B 
×
 100 = less than ± 6 (%)
1 track jump waveform
+
BSL board
TP (TE)
TP (VC)
oscilloscope
A
B
symmetry
within 3 
±
 1 Vp-p
Center of the waveform
B
level : 1.5       Vp-p
symmetry
A (DC voltage)
0V
+1.5
–0.5
Page of 36