– 13 –
*3 Aging cycle count function:
Functions which displays the number of agings carried out on
the Fluorescent indicator tube  in numbers. One aging cycle
consists of six discs.
Contents
Name
Code number
No disc in the specified slit
Disc in other slits
No function
No table sensor input
Load in timeover
Load out timeover
Access timeover
High speed search NG
Q data read error
BU operation (From focus search to until signal can be read) timeover
GFS monitor error
Focus cannot be imposed by focus search
DISC sensor check 1
DISC sensor check 2
Table operation check 2
Loading operation check 1
Loading operation check 2
BU related check 1
BU related check 2
BU related check 3
BU related check 4
BU related check 5
BU related check 6
Err 01
Err 02
Err 03
Err 04
Err 05
Err 06
Err *1
Err *2
Err *3
Err *4
Err *5
Err *6
Aging procedure:
Some operating method will be changed depending on if the fol-
lowing jig for the aging mode exists or not.
• Jig
Parts. No
Description
J-2501-123-A
Remote commander (For aging mode)
With remote commander for aging mode:
1. Turn ON the power of the unit. Open the front cover.
2. Press the 
[AGING START]
 button of the remote commander for
aging mode.
3. When the disc set mode is set, the  
·  and  P  LEDs blink.
4. Rotate the JOG dial. The slits (No. 10, 20, 30, 40, 51) for setting
the discs will come forward. Insert the discs into these slits. Do
not set the discs in other slits.
5. Set the use/disuse of the self protection function in errors. Press
the 
[REPEAT]
 button. When REPEAT is displayed on the fluo-
rescent indicator tube, the self protection function during the
error will become “Use”.
If the REPEAT display is OFF, it means that the function is not
used. (Normally set to “Use” when performing aging.)
6. Press the  
·  button.
7. The  
·  LED blinks, the aging mode is set, and aging is started.
8. The aging cycle lasts 3 minutes. When problems occur during
aging, the error number will be displayed on the fluorescent in-
dicator tube, and the  
P  LED will light up.
(Refer to the following table for the details of the errors.)
9. Aging will be repeated as long as no errors occur.
10. After each aging cycle, the number displayed on the Fluores-
cent indicator tube will increase.
11. To end aging, press the
I
/
u
button
Error Display
Without remote commander for aging mode:
1. Turn ON the power of the unit. Open the front cover.
2. Press the 
[PLAY MODE]
,  
·  , and  ≠  buttons in order.
3. When the disc set mode is set, the  
·  and  P  LEDs blink.
The following procedure is the same as in the case “With remote
commander for aging mode”.
The * numbers mean the following according to the state of the unit during aging
2 : From checking to end of TOC read
3 : From end of TOC read to end of last track playback
4 : From end of last track playback to end of first track playback
Error code
1 DISCS
TRACK
MIN
SEC
DISC
CD1
5 1
1
1
0 . 0 2
Disc number
Aging carried
(Hexadecimal)
Track number
1 DISCS
DISC
CD1
4 0
1
1Err*01
Disc number
Error code
– 14 –
SECTION 5
MECHANICAL ADJUSTMENTS
To adjust the mechanism section, enter the mechanism section adjustment mode.
For how to enter the mechanism section adjustment mode, refer to each adjustment section.
DISC SENSOR ALIGMENT
1. Make sure that there is no disc in the unit.
2. Connect an oscilloscope to TP501 of the MAIN board.
3. While pressing the 
[CLEAR]
 and 
[PLUS ONE]
 buttons at the same time and turn ON the power.
4. The fluorescent indicator tube shows as follows, and the mechanism section adjustment mode is set.
5. The disc table rotates in the clockwise direction. The disc table rotation time is displayed with ‘’PLUS ONE” slit as a measuring point.
6. Press the 
[CLEAR]
 button, to be rotated the disc table counterclockwise.
7. Measure the waveform of the oscilloscope when the disc table is rotating.
GND
oscilloscope
HHOUT
D.SENS
D.SENS (CH1)
HHOUT (CH2)
GND
MAIN board
TP501
CHECK button
CLEAR button
PLUS ONE button
 button
±
 button
I/
u
 button
ª
P
51
7
3
* *
.
ALL DISCS
DISC
CD1
SEC
DISC No.
Lit according to rotational direction
Blinks
PLUS ONE
– 15 –
8. Move the holder (sensor) center so that the flat portion center at the top of the D.SENS (CH1) input waveform and the ‘’H” center of
HHOUT (CH2) coincide.
9. Tighten the fixed screw to fix the disc table, then press the 
[CLEAR]
 button.
10. The disc table rotates in the clockwise direction. Measure the waveform and make sure that the flat portion center at the top of the
D.SENS (CH1) input waveform and the ‘’H” center of HHOUT (CH2) conform.
Note:
During the adjustment mode, the rotational direction is switched each time the 
[CLEAR]
 button is pressed.
Pressing the 
[CHECK]
 button enters the loading mode which will be described later. Pressing the 
[CLEAR]
 button rotates the disc table again.
Contets of the fluorescent indicator tube's display in the loading mode
HHOUT (CH2) waveform
D.SENS (CH1) waveform
Flat portion center of
D. SENS (CH1) waveform
Fixed screw
Holder (sensor)
51
O N
I N
O F F
ALL DISCS
DISC
CD1
Loading OUT
SW condition
Loading
direction
Loading IN
SW condition
– 16 –
MAGNET ASSY ALIGMENT
1. Check that there is no disc in the unit and then turn ON the power. Open the door, and set a disc in the PLUS ONE slit.
2. Turn OFF the power, close the door, and while pressing the 
[CLEAR]
 and 
[PLUS ONE]
 buttons simultaneously, turn ON the power
again.
3. Press the 
[CHECK]
 button, and set the loading mode.
4. Press the  
±  button and chuck the disc.
5. Adjust the magnet assembly and magnet holder so that A=B as shown in the figure.
DISC HOLDER A ALIGMENT
1. Check that there is no disc in the unit and then turn ON the power. Open the door, and set a disc in the PLUS ONE slit.
2. Turn OFF the power, close the door, and while pressing the 
[CLEAR]
 and 
[PLUS ONE]
 buttons simultaneously, turn ON the power
again.
3. Press the 
[CHECK]
 button, and set the loading mode.
4. Press the  
±  button and chuck the disc.
5. Press  
≠  or  ±  button to stop the disc holder A slightly away from the disc.
6. Rotate and adjust the adjusting screw so that the center of the disc and that of the disc holder coincide.
Magnet ASSY
Magnet ASSY
Magnet holder
Screw (For adjustment)
A   B
Disc
Disc
Disc holder A
Disc holder A
a  b
a = b
Screw (For adjustment)
Page of 58