26
CDP-CX455
Electrical Adjustment
Note:
1.
CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2.
Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10M
Ω impedance.
4.
Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
S-Curve Check
Procedure :
1.
Chuck the disc (YEDS-18) beforehand.
2.
Connect oscilloscope to test point TP (FE1) on BD board.
3.
With the power ON, while pressing the TIME and MEGA
CONTROL  buttons, press the  
1/u  button.
Rotate the  DISC/ALBUM/CHARACTER  dial, select “BU
Test” and press the dial.
4.
Rotate the  DISC/ALBUM/CHARACTER  dial, and select “bdt
S CURVE”. Press the dial “LD AL” is displayed.
5.
Check the oscilloscope waveform (S-curve) is symmetrical
between A and B. And confirm peak to peak level within 3±1
Vp-p.
S-curve waveform
6.
Pressing the MENE/NO  button stops the output of the
waveform (S CURVE). “bdt S CURVE”is displayed.
7.
To end this mode, press the  ?/1  button.
Note : • Try to measure several times to make sure than the ratio of
A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
Adjustment Location: BD board (See page 28)
RF Level Check
oscilloscope
BD board
TP (FE1)
TP (DVC)
symmetry
A
B
Within 3 
±
 1 Vp-p
VOLT/DIV : 1V
TIME/DIV : 400 
µ
s
oscilloscope
BD board
TP (RFAC)
TP (DVC)
VOLT/DIV : 500mV
TIME/DIV : 1 
µ
s
level : 1.2         Vp-p
+0.25
–0.20
Procedure :
1.
Connect oscilloscope to test point TP (RFAC) on BD board.
2.
Turn Power switch on.
3.
Put disc (YEDS-18) in to play the number five track.
4.
Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
Note: A clear RF signal waveform means that the shape “
◊” can be
clearly distinguished at the center of the waveform.
RF signal waveform
Adjustment Location: BD board (See page 28)
27
CDP-CX455
1.
Connect the oscilloscope to Pins 1, 2, and 3 of TP1 of the
MAIN board.
2.
Check that no discs are loaded in the unit.
3.
With the power ON, while pressing the  TIME  and MEGA
CONTROL buttons, press the  
1/u    button. Rotate the  DISC/
ALBUM/CHARACTER  dial, select “CDM Test” and press the
dial.
Rotate the  DISC/ALBUM/CHARACTER  dial and select
“TableRotation” and press the dial.
The disc table starts to rotate in the clockwise direction.
4.
Loosen the fixing screw, move the mounting board (SENSOR),
and secure the mounting board (SENSOR) at the point the H
portion of the H-H waveform comes the center of the H portion
of the D.SENS waveform.
Disc Sensor Adjustment
Be sure to perform this adjustment after sensor adjustment in
MECHANICAL ADJUSTMENT.
Connection:
Waveform:
5.
Rotate the  DISC/ALBUM/CHARACTER  knob in the
counterclockwise direction and the disc table starts to rotate in
the same direction. Check that the waveform at this time is the
same as that in step 4. If larger by a considerable extent, rotate
the  DISC/ALBUM/CHARACTER  knob in the clockwise
direction and the disc table starts to rotate in the same direction.
Repeat from step 4.
6.
Rotate RV501 of the MAIN board and adjust so that the H and
L portions of the D.S waveform become the same.
S tight,  screw 
(PTTWH 3 
×
 6)
D. sens (out) board
D.SENS
H-H
CH1
CH2
D.SENS
H-H
CH1
CH2
Should be at the center
D.SENS
CH1
Adjust so that these widths
become the same.
D.SENS OUT: Pin 
1
GND: Pin 
2
H-H OUT: Pin 
3
oscilloscope
CH1 CH2
D.SENS OUT
GND
H-H OUT
MAIN board
TP1
Adjustment Location: MAIN board (See page 28)
Spray Mode
• This mode is used for the measurement of the table sensor signal
outputs characteristics.
Procedure :
1.
Check that no discs are loaded in the unit.
With the power ON, while pressing the  TOP ARTIAT 8  and
H  buttons, press the  +100  button.
“Spray Mode” is displayed.
2.
Press the H button to start the measurement. “Now ···ing” is
displayed during the measurement of one rotarion.
3.
The result of the measurement is displayed as below.
4.
To end this mode, press the  
1/u  button.
DISC
CD TEXT
1
CD2
GROUP
NO DELAY
MULTI
PROGRAM 1 2 3 X-FADE
DELETE
CD3
REPEAT
SHUFFLE
1
SEC
STEP
MIN
ART.
GROUP
TRACK
HIT
ART.
NEXT
2nd
P = 3 .6 V   b = 1 .4 V
Minimum value
of the peak at the 
High/High part of 
TSENS1/TSENS2
Maximum value
of the bottom at the
LOW/LOW part of 
TSENS1/TSENS2
display
28
CDP-CX455
[ BD BOARD ] – Conductor Side –
Adjustment Location :
[ MAIN BOARD ] – Component Side –
TP(FE1)
TP(DVC)
TP(RF AC)
IC 103
IC 101
TP1
TP(AFADJ)
GND
TP(ADJ)
1
3
RV501
DISC SENSOR
ADJUSTMENT
IC501
IC504
– Conductor Side –
CDP-CX455
29
29
THIS NOTE IS COMMON FOR PRINTED WIRING
BOARDS AND SCHEMATIC DIAGRAMS.
(In addition to this, the necessary note is printed
in each block.)
For schematic diagrams.
Note:
• All capacitors are in µF unless otherwise noted.  pF: µµF
50 WV or less are not indicated except for electrolytics
and tantalums.
• All resistors are in 
 and 
1
/
4
 
W or less unless otherwise
specified.
¢
: internal component.
C
: panel designation.
A
: B+ Line.
B
: B– Line.
H
: adjustment for repair.
• Voltages and waveforms are dc with respect to ground
under no-signal (detuned) conditions.
no mark : STOP
• Voltages are taken with a VOM (Input impedance 10 M
).
Voltage variations may be noted due to normal produc-
tion tolerances.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal produc-
tion tolerances.
• Circled numbers refer to waveforms.
• Signal path.
J
: CD
c
: digital out
• Abbreviation
CND : Canadian model
For printed wiring boards.
Note:
• X
: parts extracted from the component side.
• Y
: parts extracted from the conductor side.
®
: Through hole.
: Pattern from the side which enables seeing.
(The other layers' patterns are not indicated.)
Waveforms
Note:
The components identi-
fied by mark 
!
 or dotted
line with mark 
!
 are criti-
cal for safety.
Replace only with part
number specified.
Note:
Les composants identifiés par
une marque 
!
 sont critiques
pour la sécurité.
Ne les remplacer que par une
piéce por tant le numéro
spécifié.
Caution:
Pattern face side: Parts on the pattern face side seen from the
(Side B)
pattern face are indicated.
Parts face side:
Parts on the parts face side seen from the
(Side A)
parts face are indicated.
• Indication of transistor
C
These are omitted
E
B
Q
C
These are omitted
E
B
SECTION  6
DIAGRAMS
6-1. Circuit Boards Location
LED board
MAIN board
TRANS board
D. MOTOR board
JOG board
BD board
DOOR SW board
T. SENS board 
KEYBOARD board
D. SENS 
(OUT) board
DISP board
D. SENS (IN) board
LOADING SW board
L. T. MOTOR board
LOCK SW board
3.8Vp-p 
1
 IC104 
yd
 XO
1V/DIV, 20ns/DIV
59ns
1.3Vp-p
500mV/DIV, 1
µ
s/DIV
200mV/DIV, 20ms/DIV
200mV/DIV, 4ms/DIV
1V/DIV, 4
µ
s/DIV
1V/DIV, 20ns/DIV
2
 IC103 
qg
 (RFAC)
3
 IC101 
ra
 TE
4
 IC101 
el
 FE
2.1 Vp-p
5
 IC101 
wg
 MDP
3.5 Vp-p
6
 IC501 
ek
 X2
7.5 
µ
s
62.5 ns
(PLAY)
1.65V
APPROX 500mVp-p (PLAY)
1.65V
APPROX 500m Vp-p (PLAY)
Page of 67