Sony CDP-CX355 Service Manual ▷ View online
25
CDP-CX355
SECTION 5
TEST MODE
5-1. ADJ Mode
1.
Turn ON the power of the unit, set disc to disc table, and perform
chucking.
chucking.
2.
Disconnect the power supply plug from the outlet.
3.
To set ADJ mode, connect the test point (ADJ) of the MAIN
board to Ground, and connect the power supply plug to the
outlet.
board to Ground, and connect the power supply plug to the
outlet.
In this mode, table rotation and loading operations are not performed
because it is taken that the disc has already been chucked.
because it is taken that the disc has already been chucked.
Note: The same operations are also performed in the following when
the test point (ADJ) is connected to Ground after turning on
the power.
the power.
• Direct search (movement of sledding motor) is not performed dur-
ing accessing
• Ignored even when GFS becomes L
• Ignored even when the Q data cannot be read
• Focus gain does not decrease
• Ignored even when the Q data cannot be read
• Focus gain does not decrease
ADJ Mode Special Functions Table
(The buttons shown with ( ) function by using the sup-
plied remote commander only)
(The buttons shown with ( ) function by using the sup-
plied remote commander only)
5-2. Key and Display Check Mode
To set this mode, connect the test point (AFADJ) on the MAIN
board to Ground, and connect the power supply plug to the outlet.
board to Ground, and connect the power supply plug to the outlet.
Note: When this mode is executed, all title memos recorded will be
erased.
• When this button is pressed, “line # No. #” will be displayed.
However, these will not be displayed for the following special
buttons. However, these will not be displayed for the following
special buttons.
buttons. However, these will not be displayed for the following
special buttons.
p (stop) button: FL segment check
(Refer to FL Tube Check Patterns)
P (pause) button: FL grid check
(Refer to FL Tube Check Patterns)
The
The
P LED also light up simultaneously.
· (play) button: All FL segment and grid will light up.
All LEDs also light up simultaneously.
TIMER switch:
When the switch position is PLAY , the
STANDBY LED light up. It goes off when
set to OFF.
STANDBY LED light up. It goes off when
set to OFF.
Each time this button is pressed, the value of the “Got ## keys”
increases. Buttons pressed once will not be counted when pressed
again.
increases. Buttons pressed once will not be counted when pressed
again.
FL Tube Check Patterns
Segment check
A B C D E F G
• When the jog dial is rotated to the right, the GROUP LEDs light
up in the order of 1
n2..8nHIT LISTnEASY PLAYnMEGA
CONTROL
n1.
• When the jog dial is rotated to the left, the GROUP LEDs light up
in the order of 8
n 7..1n MEGA CONTROLn EASY
PLAY
nHIT LISTn8.
• Abbreviation
FL: Fluorescent Indicator Tube
FL: Fluorescent Indicator Tube
[ MAIN BOARD ] – Cnductor Side –
Grid check
Button
CONTINUE
SHUFFLE
PROGRAM
GROUP 3 (3)
GROUP 8 (8)
CHECK
Function
Servo average display
Displays VC, FE, RF, TE and traverse in hexadecimal
numbers
Displays VC, FE, RF, TE and traverse in hexadecimal
numbers
Focus bias display
Each time this is pressed, the focus bias is switched
between (1) and (2)
between (1) and (2)
(1)
Bias actually set Optimum bias Minimum jitter
(2)
U:Upper aliasing bias L:Lower aliasing bias
Bias actually set Optimum bias Minimum jitter
(2)
U:Upper aliasing bias L:Lower aliasing bias
Auto gain display
Displays focus, tracking, sledding in hexadecimal
numbers
numbers
Turns off the tracking and sledding servo
Turns on the tracking and sledding servo
S-curve observation mode.
(Exits this mode when the
(Exits this mode when the
1/u button is pressed.)
Magnified
TP (AFADJ)
TP (ADJ)
IC504
IC501
26
CDP-CX355
SECTION 6
ADJUSTMENTS
6-1. Mechanical Adjustments
Pop Up Mechanism Adjustment
1.
1.
With the power ON, while pressing the GROUP 4 and
·
buttons, press the +100 button to enter the mechanism
adjustment mode.
adjustment mode.
2.
Press the GROUP 1 button to operate the loading mechanism,
and continue pressing until the disc table locks. (Fig-1)
and continue pressing until the disc table locks. (Fig-1)
3.
Press the GROUP 2 button to raise the pop up part.
4.
Remove the cover (chassis), loosen the adjusting screw, move
the screwdriver left and right until the lever (POP UP) does not
touch the slit wall, and secure the screw. (Fig-2)
the screwdriver left and right until the lever (POP UP) does not
touch the slit wall, and secure the screw. (Fig-2)
The following buttons have special functions in this mode.
GROUP 1 button: Loading mechanism IN operation
GROUP 5 button: Loading mechanism OUT operation
GROUP 2 button: Pop up part UP operation
GROUP 6 button: Pop up part DOWN operation
GROUP 5 button: Loading mechanism OUT operation
GROUP 2 button: Pop up part UP operation
GROUP 6 button: Pop up part DOWN operation
Lever (pop up)
Fix to the center so that the
lever (POP UP) does not
touch the slit.
lever (POP UP) does not
touch the slit.
Cover (chassis)
FIg-1
FIg-2
GROUP1
GROUP2
GROUP2
GROUP4
At this position,this
part will be locked.
part will be locked.
27
CDP-CX355
GROUP1
GROUP4
PAUSE button
PLAY button
Fixed screws
Swing
Holder (table sensor)
Table assembly
At this position,this
part will be locked.
part will be locked.
Sensor Adjustment
1.
1.
With the power ON, while pressing the GROUP 4 and
·
buttons, press the +100 button to enter the mechanism
adjustment mode.
adjustment mode.
2.
Press the GROUP 1 button to operate the loading mechanism,
and continue pressing until the disc table locks. (Fig-3)
and continue pressing until the disc table locks. (Fig-3)
3.
Loosen the fixing screw, move the holder (TABLE SENSOR)
slightly, and when the LED (green) of the PLAY button
switches to the LED (orange) of the PAUSE button (or vice
versa), secure the holder (TABLE SENSOR). (Fig-4)
slightly, and when the LED (green) of the PLAY button
switches to the LED (orange) of the PAUSE button (or vice
versa), secure the holder (TABLE SENSOR). (Fig-4)
4.
Moving the disc table right and left with a hand after the screw
is fixed, the table will move by the play of a disc table. If the
LEDs light up alternately, the adjustment will be performed
correctly. (Fig-4)
is fixed, the table will move by the play of a disc table. If the
LEDs light up alternately, the adjustment will be performed
correctly. (Fig-4)
FIg-3
FIg-4
PLAY indicator
Linked with
· indicator
Linked with
P indicator
PAUSE indicator
28
CDP-CX355
6-2. Electrical Adjustment
Note:
1.
1.
CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
Therefore, check each item in order given.
2.
Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10M
Ω
impedance.
4.
Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
when the signal level is low than specified value with the
following checks.
S-Curve Check
Procedure :
1.
1.
Chuck the disc (YEDS-18) beforehand, and disconnect the
power cord from the outlet.
power cord from the outlet.
2.
Connect oscilloscope to test point TP (FE1) on BD board.
3.
Connect test point TP (ADJ) on MAIN board to ground with
lead wire.
lead wire.
4.
The ADJ mode is set when the power cord is inserted into the
outlet and power is supplied.
outlet and power is supplied.
5.
The fifth track is played automatically.
6.
Press the CHECK button.
7.
Check the oscilloscope waveform (S-curve) is symmetrical
between A and B. And confirm peak to peak level within 3±1
Vp-p.
between A and B. And confirm peak to peak level within 3±1
Vp-p.
S-curve waveform
8.
Pressing the
1/u button stops the output of the waveform (s
curve).
9.
After check, remove the lead wire connected in step 3.
Note : • Try to measure several times to make sure than the ratio of
A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
Adjustment Location: BD board (See page 30)
RF Level Check
Note: A clear RF signal waveform means that the shape “
◊
” can be
clearly distinguished at the center of the waveform.
RF signal waveform
Adjustment Location: BD board (See page 30)
E-F Balance Check
Procedure :
1.
1.
Chuck the disc (YEDS-18) beforehand, and disconnect the
power cord from the outlet.
power cord from the outlet.
2.
Connect oscilloscpe to test point TP (TE1) on BD board.
3.
Connect test point TP (ADJ) on MAIN board to ground with
lead wire.
lead wire.
4.
The ADJ mode is set when the power cord is inserted into the
outlet and power is supplied.
outlet and power is supplied.
5.
The fifth track is played automatically.
6.
Press the GROUP 3 button. (The tracking servo and the
sledding servo are turned OFF.) “ TRK Off ” is displayed.
sledding servo are turned OFF.) “ TRK Off ” is displayed.
7.
Check the level B of the oscilliscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
Traverse waveform
8.
Press the GROUP 8 button. (The tracking servo and sledding
servo are turned ON.) “ TRK On ” is displayed. Confirm the C
(DC voltage) is almost equal to the A (DC voltage) is step 7.
servo are turned ON.) “ TRK On ” is displayed. Confirm the C
(DC voltage) is almost equal to the A (DC voltage) is step 7.
Traverse waveform
Procedure :
1.
1.
Connect oscilloscope to test point TP (RFAC) on BD board.
2.
Turn Power switch on.
3.
Put disc (YEDS-18) in to play the number five track.
4.
Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
signal level is correct or not.
oscilloscope
BD board
TP (FE1)
TP (VC)
TP (VC)
symmetry
A
B
Within 3
±
1 Vp-p
VOLT/DIV : 1V
TIME/DIV : 400
TIME/DIV : 400
µ
s
oscilloscope
BD board
TP (RFAC)
TP (VC)
TP (VC)
VOLT/DIV : 500mV
TIME/DIV : 1
TIME/DIV : 1
µ
s
level : 1.2 Vp-p
+0.25
–0.20
–0.20
oscilloscope
BD board
TP (TE1)
TP (VC)
TP (VC)
0V
level : 1.3
±
0.6 mVp-p
A (DC voltage)
Center of the waveform
B
0V
C (DC
voltage)
voltage)
Tracking servo
Sledding servo
OFF
Sledding servo
OFF
Tracking servo
Sledding servo
ON
Sledding servo
ON
9.
After check, disconnect the lead wire of TP (ADJ) connected
in step 3.
in step 3.
Adjustment Location: MAIN board (See page 30)
Click on the first or last page to see other CDP-CX355 service manuals if exist.