MECHANISM DECK CHECK MODE
For the mechanism deck check mode, two modes of disc table mode and loading mode are available.
In the mechanism deck check mode, the disc table turning time and the loading time in each section are measured and displayed.
In the mechanism deck check mode, the disc table turning time and the loading time in each section are measured and displayed.
1. Disc table mode:
Press the
[POWER]
switch while pressing
[CHECK]
,
[ OPEN/CLOSE]
and
[REPEAT]
buttons simultaneously.
Loading mode:
Press the
Press the
[POWER]
switch while pressing
[CHECK]
,
[ OPEN/CLOSE]
and
[TIME]
buttons simultaneously.
A
A
Display contents
Mode
Check command
Display
Disc table mode
0: Right one turn
r 12.5
Table turning
1: Left one Turn
L 10.2
(
time measurement
)
2: Measurement end
r 12.5
3: Undefined
4: Star position
Sta
– –.–
5: Open
→
Close
CLo 10.2
6: Close
→
BU up
UP
0.7
Table mode
7: BU up
→
EX open
EoP
6.2
Loading time
8: EX open
→
EX close
ECL 10.3
(
measurement
)
9: EX close
→
BU down
don
1.2
A: BU down
→
Open
oPn
9.3
FF: Measurement end
CLo 10.2
14
SECTION 5
ELECTRICAL CHECKING
Note:
1. CD Block is basically designed to operate without adjustment. There-
fore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10 M
3. Use an oscilloscope with more than 10 M
Ω
impedance.
4. Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
S-Curve Check
Procedure:
1. Connect oscilloscope to TP (FE) and TP (VC) on the BD board.
2. Connect between TP (FE1) and TP (VC) with lead wire.
3. Connect between TP (AGCCON) and TP (GND) with lead
1. Connect oscilloscope to TP (FE) and TP (VC) on the BD board.
2. Connect between TP (FE1) and TP (VC) with lead wire.
3. Connect between TP (AGCCON) and TP (GND) with lead
wire.
4. Turned power switch (
[POWER]
button) on.
5. Load a disc (YEDS-18) and actuate the focus search. (In con-
sequence of open and close the disc tray, actuate the focus
search)
search)
6. Cofirm that the oscilloscope waveform (S-curve) is symmetri-
cal between A and B. And confirm peak to peak level within
4 ± 1 Vp-p.
4 ± 1 Vp-p.
S-curve waveform
7. After check, remove the lead wire connected in step 2 and 3.
Note:
• Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the brightness to
obtain best waveform.
RF Level Check
Procedure:
1. Connect oscilloscope to TP (RF) and TP (VC) on BD board.
2. Connect between TP (AGCCON) and TP (GND) with lead
1. Connect oscilloscope to TP (RF) and TP (VC) on BD board.
2. Connect between TP (AGCCON) and TP (GND) with lead
wire.
3. Turned power switch (
[POWER]
button) on.
4. Load a disc (YEDS-18) and playback.
5. Confirm that the oscilloscope waveform is clear and check RF
5. Confirm that the oscilloscope waveform is clear and check RF
signal level is correct or not.
6. After check, remove the lead wire connected in step 2.
Note:
Clear RF signal waveform means that the shape “
◊
” can be clearly
distinguished at the center of the waveform.
E-F Balance (1 Track Jump) Check
Procedure :
1. Connect oscilloscope to TP (TE) and TP (VC) on BD board.
2. Turned power switch (
1. Connect oscilloscope to TP (TE) and TP (VC) on BD board.
2. Turned power switch (
[POWER]
button) on.
3. Load a disc (YEDS-18) and playback the number five track.
4. Press the
4. Press the
H
button. (Becomes the 1 track jump mode)
5. Confirm that the level B and A (DC voltage) on the oscillo-
scope waveform.
1 track jump waveform
Specified level:
×
100 = less than ± 22%
6. After check, remove the lead wire connected in step 1.
RF PLL Free-run Frequency Check
Procedure :
1. Connect frequency counter to TP (PLCK) with lead wire.
1. Connect frequency counter to TP (PLCK) with lead wire.
2. Turned power switch (
[POWER]
button) on.
3. Put the disc (YEDS-18) in to play the number five track.
Confirm that reading on frequency counter is 4.3218 MHz.
A
B
B
+
–
–
BD board
TP (FE)
TP (VC)
TP (VC)
oscilloscope
A
B
symmetry
within 4
±
1 Vp-p
+
–
–
BD board
TP (RF)
TP (VC)
TP (VC)
oscilloscope
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
TIME/DIV: 500 ns
level:
1.45
1.45
±
0.3 Vp-p
+
–
–
BD board
TP (TE)
TP (VC)
TP (VC)
oscilloscope
A (DC voltage)
center of
waveform
waveform
B
0V
level = 1.3
±
0.6 Vp-p
symmetry
TP (PLCK)
BD board
frequency counter
+
–
15
TP (VC)
TP (RF)
TP (FE)
TP (TE)
TP
(FE1)
TP (GND)
TP
(PLCK)
TP
(AGCCON)
CN102
IC101
Checking Location: