DOWNLOAD Sony CDP-C591 / CDP-CE235 / CDP-CE335 / SEN-R2900 Service Manual ↓ Size: 2.41 MB | Pages: 28 in PDF or view online for FREE

Model
CDP-C591 CDP-CE235 CDP-CE335 SEN-R2900
Pages
28
Size
2.41 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / S/M CDP-C591/CE235/CE335 99 US
File
cdp-c591-cdp-ce235-cdp-ce335-sen-r2900.pdf
Date

Sony CDP-C591 / CDP-CE235 / CDP-CE335 / SEN-R2900 Service Manual ▷ View online

— 7 —
2-3. OPTICAL PICK-UP BLOCK ASSEMBLY
2-4. BRACKET (GEAR) ASSEMBLY
Note :
As for the installation of the main gear, refer to “Note for MAIN
GEAR installation” on page 4.
5
 Two screws 
    (PTPWH 2.6 
×
 6)
4
 Two screws 
    (PTPWH 2.6 
×
 6)
7
 Compression spring(BU)
1
 Pull out the tray.
    (Refer to "HOW TO OPEN THE DISC TRAY WHEN
      POWER SWITCH TURNS OFF" on page 4.)
6
 Holder (BU)
8
 Compression spring (BU)
9
 Optical pick-up block assembly
2
 Flat type wire(16 core)
    (BD board, to CN101)
3
 Screw
    (PTPWH 3 
×
 12)
6
 Rotary encoder
4
 Gear (MAIN)
2
 Gear (REV)
8
 Gear (U/D)
0
 Bracket (GEAR)
    assembly
3
 Stopper washer(5)
1
 Stopper washer(5)
7
 Stopper washer(5)
5
 Screws 
    (BVTP 3 
×
 8)
9
 Five screws 
    (BVTP 3 
×
 8)
— 8 —
SECTION  3
TEST MODE
1
 ADJ Mode
When the main power is turned on while the ADJ terminal is set to
LOW, the CDP-C591/CE235/335 enters the ADJ mode that enables
to implement the servo related checks.
The disk tray is not loaded or rotated.
The fifth program is automatically played back.
The following items are valid even when the main power is turned
on first and the ADJ terminal is then set to LOW.
The high speed search cannot be performed.
The focus servo gain is not decreased.
CLV servo gain is not decreased.
GFS is ignored even if it is set to the LOW.
Q data is ignored even if it cannot be read.
Switching of the monitor terminal is possible.
Every pressing of the FADER key advances the MONITOR
terminal in the following order.
RFCK
nGFCnError rate
When “3” of the remote controller is pressed, the tracking servo
is turned off.
When “8” of the remote controller is pressed, the tracking servo
is turned on.
* The servo related items cannot be checked in the CDP-C591/
CE235/335.
2
 Key Check and Display Check Mode
When the main power is turned on while the AFADJ terminal is set
to LOW, the CDP-C591/CE235/335 enters the key check and display
check mode in which keys and displays can be checked.
First, all display tubes turn on.
When any key is pressed after display tubes are turned on, the
number of the keys that have been pressed appear on the left
and the key number appears on the right.
(Pushing the JOG key is counted as one of the keys.)
However, the following keys are treated as the special keys
that show the different operations.
STOP
: All display turn-on check
PLAY
: Grid check
PAUSE : Segment check
JOG
: Calendar check
When receiving a signal from remote controller, the display
“ []– ** ” appears.
(Number of asterisks ** changes depending on the pressed
key. For example, ** is 50 when the PLAY key is pressed.)
3
 Default Shipment Mode
When the main power is turned on while pressing the DISCSKIP
and the PROGRAM keys, the CDP-C591/CE235/335 enters the
default shipment mode in which the default settings when shipped
from the factory are set.
Move the DISC 1 to the front and stop the machine.  When the
message “NODISC” appears, it indicates that the mode has
ended with success.
4
 Aging Mode
When the OPEN key is pressed while the DISC1 and the CHECK
keys are being pressed with the main power being turned ON, the
CDP-C591/CE235/335 enters the aging mode in which aging is
performed in the following sequence.
Reads TOC
A-1
Accesses the last program
A-2
Plays the last program for 3 seconds
PLAY display appears
EX-CHANGE
A-4
DISCSKIP
A-5
CLOSE
A-6
Accesses the first program
A-7
Playback the first program
PLAY display appears
OPEN
A-9
DISPSKIP
A-A
CLOSE
A-0
When an error occurs during aging, the message “Err–*” appears
and the operation is stopped.
The system does not accept any key operations during aging.
— 9 —
— 10 —
RF PLL Free-run Frequency Check
Procedure :
1.
Connect frequency counter to TP (PLCK) with lead wire.
2.
Turned Power switch on.
3.
Put the disc (YEDS-18) in to play the number five track.
Confirm that reading on frequency counter is 4.3218MHz.
Adjustment Location :
[ BD BOARD ] — Conductor Side —
BD board
TP (PLCK)
frequency counter
TP(VC)
TP(RF)
TP(TE)
TP(TE1)
CN102
TP(FE)
TP(PLCK)
TP(GND)
TP(FE1)
TP(AGCCON)
IC101
20
21
40
41
60
61
80
1
Note :
Clear RF signal waveform means that the shape “ 
 ” can be clearly
distinguished at the center of the waveform.
E-F Balance (1 Track jump) Check
Procedure :
1.
Connect oscilloscope to TP (TE) and TP (VC).
2.
Turned Power switch on.
3.
Load a disc (YEDS-18) and playback the number five track.
4.
Press the  
(  button. (Becomes the 1 track jump mode.)
5.
Confirm that the level B and A (DC voltage) on the oscilloscope
waveform.
Note :
1.
CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2.
Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10M
 impedance.
4.
Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
S-Curve Check
Procedure :
1.
Connect oscilloscope to TP (FE).
2.
Connect between TP (FE1) and TP (VC) by lead wire.
3.
Connect between TP (AGCCON) and TP (GND) by lead wire.
4.
Turn Power switch on.
5.
Load a disc (YEDS-18) and actuate the focus search. (In
consequence of open and close the disc tray, actuate the focus
search)
6.
Confirm that the oscilloscope waveform (S-curve) is
symmetrical between A and B. And confirm peak to peak level
within 4 ±1 Vp-p.
7.
After check, remove the lead wire connected in step 2 and 3.
Note :
• Try to measure several times to make sure than the ratio
of A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF Level Check
Procedure :
1.
Connect oscilloscope to TP (RF).
2.
Connect between TP (AGCCON) and TP (GND) by lead wire.
3.
Turned Power switch on.
4.
Load a disc (YEDS-18) and playback.
5.
Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
6.
After check, remove the lead wire connected in step 2.
SECTION 4
ELECTRICAL BLOCK CHECKING
BD board
Oscilloscope
TP(FE)
TP(VC)
symmetry
S-curve waveform
within 4 
±
1Vp-p
A
B
TP(RF)
TP(VC)
BD board
oscilloscope
RF signal waveform
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.45 
±
 0.3Vp-p
TP(TE)
TP(VC)
BD board
oscilloscope
level=1.3
±
0.6Vp-p
symmetry
A (DC voltage)
center of
waveform
B
0V
1 track jump waveform
Specified level: –– 
×
 100=less than 
±
22%
B
A
CDP-C591/CE235/CE335
5-1. CIRCUIT BOARDS LOCATION
SECTION  5
DIAGRAMS
BD BOARD
SENSOR BOARD
MAIN BOARD
DISPLAY BOARD
KEY BOARD
POWER SW BOARD
LOADING MOTOR BOARD
TABLE MOTOR BOARD
THIS NOTE IS COMMON FOR PRINTED WIRING
BOARDS AND SCHEMATIC DIAGRAMS.
(In addition to this necessary note is printed in
each block)
Note on Schematic Diagram:
• All capacitors are in µF unless otherwise noted.  pF: µµF
50 WV or less are not indicated except for electrolytics
and tantalums.
• All resistors are in 
 and 
1
/
4
 
W or less unless otherwise
specified.
%
: indicates tolerance.
¢
: internal component.
C
: panel designation.
U
: B+ Line.
V
: B– Line.
• Voltages and waveforms are dc with respect to ground
under no-signal (detuned) conditions.
• Voltages are taken with a VOM (Input impedance 10 M
).
Voltage variations may be noted due to normal produc-
tion tolerances.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal produc-
tion tolerances.
• Circled numbers refer to waveforms.
• Signal path.
J
: CD
c
: CD DIGITAL
• Abbreviation
CND
: Canadian
AED
: North European
AUS
: Aurstrarian
EA
: Saudi Arabia
SP
: Singapore
Note:
The components identi-
fied by mark 
!
 or dotted
line with mark 
!
 are criti-
cal for safety.
Replace only with part
number specified.
Note:
Les composants identifiés par
une marque 
!
 sont critiques
pour la sécurité.
Ne les remplacer que par une
piéce por tant le numéro
spécifié.
— 11 —
— 12 —
Note on Printed Wiring Boards:
• X
: parts extracted from the component side.
¢
: internal component.
• b
: Pattern from the side which enables seeing.
Page of 28
Display