9
2-5.  DSP  BOARD,  MAIN  BOARD
A
A
B
C
C
B
1
 three screws
 (BVTP3 
u 6)
1
 screw 
 (BVTP3 
u 6)
2
 clamp
qf
 connector (CN101)
9
 wire (flat type) 
 
(26 core) (CN106)
q;
 wire (flat type) 
 
(21 core) (CN105)
qg
 screw (BV3 
u 8)
qh
 clamp
6
 wire (flat type) (19 core)
 (CN109)
qa
 D.C. fan connector
 (CN104)
8
 system cable connector 
 (CN107)
qs
 wire (flat type)
 
(17 core) (CN103)
5
 wire (flat type)
 
(15 core) (CN110)
qd
 wire (flat type)
 
(15 core) (CN102)
7
 connector
 (CN108)
ql
 MAIN board
qj
 HOLDER FFC board
qg
 two screws
 (BV3 
u 8)
qk
 P.C. board spacer
3
 connector
 (CN5001)
4
 DSP board
qg
 screw (BV3 
u 8)
HCD-Z7
10
2-6.  BD  DRIVE (BPD-200)
4
 two screws (BV3)
6
 saranet cushion
7
 harness
4
 two screws
 (BV3)
1
 harness (serial ATA)
8
 BD drive
 (BPD-200)
5
2
 screw
 (BVTP3 
u 6)
3
 spring
 (front 
shield)
2
 two screws
 (BVTP3 
u 6)
3
 two springs
 (front 
shield)
2-7.  REAR  PANEL  BLOCK
4
 screw (BV3)
3
 wire (flat type)
 
(15 core) (CN604)
2
 wire (flat type)
 
(17 core) (CN605)
5
 two screws
 (BVTP3 
u 8)
6
 screw
 (BVTT3 
u 8)
5
 two screws
 (BVTP3 
u 8)
1
 D.C. fan connector
 (CN104)
7
 rear panel block
HCD-Z7
11
2-8.  MB-124  BOARD
A
B
A
B
1
 wire (flat type)
 
(26 core) (CN803)
6
 wire (flat type)
 
(19 core) (CN904)
5
 connector
 (CN301)
4
 harness (USB)
 (CN600)
3
 harness (serial ATA)
 (CN700)
2
 wire (flat type)
 
(21 core) (CN801)
8
 clamp
7
 screw (BV3)
7
 two screws
 (BV3)
9
 MB-124 board
7
 two screws
 (BV3)
HCD-Z7
12
SECTION  3
TEST  MODE
1.  TEST  MODES  OTHER  THAN  THE  TEST  MENU
These are executable test mode even if not entering the test menu.
1-1. Cold Reset
The cold reset clears data except BD/DVD data stored in the RAM 
to initial conditions. Execute this mode when returning the set to 
the customers.
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press the [
x
], [VOL –] and [
Z
] buttons simultaneously and 
hold down (around 5 seconds).
3.  The message “COLD RESET” appears on fl uorescent indica-
tor tube, then becomes standby states.
1-2.  Color System Change 
This mode let you change the color system of the video output 
from PAL to NTSC or vice versa.
Procedure:
1.  Press the [
?/1
] button to turn the power on. 
2.  Press the [
x
] and [VOL +] buttons simultaneously and hold 
down (around 5 seconds).
3.  The color system is changed.
1-3.  Disc Tray Lock
This mode let you lock the disc tray. When this mode is activated, 
the disc will not eject when the [
Z
] button is pressed. The message 
“LOCKED” will be displayed on the fluorescent indicator tube.
Procedure:
1.  Press the [
?/1
] button to turn the power on. 
2.  Press the [FUNCTION] button to select the “BD/DVD”.
3.  Press the [
x
] and [
Z
] buttons simultaneously and hold down 
until “LOCKED” or “UNLOCKED” displayed on the fluores-
cent indicator tube (around 5 seconds).
2.  TEST  MODES  IN  THE  TEST  MENU
These are the test modes done in the test menu.
Setting method of the test menu:
1.  Press the [
?/1
] button to turn the power on.
2.  Press three button in order of the [CLEAR] 
→ [
3
→ [0] → 
[1] 
→ [0] → [ANGLE] on the remote commander (Make the 
interval when each button is pressed within two seconds).
3.  The message “TEST MENU” appears on the fluorescent indi-
cator tube and enter the test menu.
2-1. Panel Test
Procedure:
1.  Enter the test menu.
2.  Press the [
M
]/[
m
] buttons on the remote commander to select 
the “PANEL TEST”, and press the [
3
] button on the remote 
commander.
3.  LEDs and all segments in fl uorescent indicator tube are lighted 
up. And half segments in fl uorescent indicator tube are lighted 
up, others half segments in fl uorescent indicator tube are light-
ed up, then LEDs and all segments in fl uorescent indicator tube 
are lighted up. This operation is repeated.
4.  When all segments in fl uorescent indicator tube are lighted up 
in the state of step 3, press the [VOLUME +] button on the 
remote commander and model information is displayed on the 
fl uorescent indicator tube.
 
Each time the [VOLUME +] button on the remote commander 
is pressed, the display changes from destination information, 
MC version, SUB version, SYS version, SYS2 version, UI 
version, DVD version, ST version, TA version, DSP version, 
TM version, CLA version, CEC version, DSPF version in this 
order, and returns to the model information display.
 
Each time the [VOLUME –] button on the remote commander 
is pressed, the version and date are switched.
5.  In the state of step 3, press the [FUNCTION] button on the 
remote commander and “K 0” is displayed on the fluorescent 
indicator tube.
 
“K 0” value increases whenever a button on the set is pressed 
or a sensor is touched. However, once a button has been 
pressed, it is no longed taken into account.
 
All buttons on the set are pressed and all sensors are touched, 
“OK” and “K 7” are alternately displayed on the fluorescent 
indicator tube.
6.  To release from this mode, press the [
?/1
] button.
2-2. AMP Test
Procedure:
1.  Enter the test menu.
2. Press the [
M
]/[
m
] buttons on the remote commander to select 
the “AMP TEST”, and press the [
3
] button on the remote 
commander.
3.  The message “MEASURE” appears on the fluorescent indica-
tor tube and enter the AMP test mode.
4.  Press the [MUTING] button on the remote commander, “VOL 
N” (The change in the volume is usual)/“VOL MSM” (The 
change in the volume is a switch of MIN/1/26/MAX) can be 
switched.
5.  Press the [SUBTITLE] button on the remote commander, the 
message “VACS ON” or “VACS OFF” appears on the fl uores-
cent indicator tube and thus the VACS on/off are changed.
6.  To release from this mode, press the [
?/1
] button.
2-3. Cold Reset
The cold reset clears data except BD/DVD data stored in the RAM 
to initial conditions. Execute this mode when returning the set to 
the customers.
Procedure:
1.  Enter the test menu.
2. Press the [
M
]/[
m
] buttons on the remote commander to select 
the “COLD RESET”, and press the [
3
] button on the remote 
commander.
3.  The message “COLD RESET” appears on the fluorescent indi-
cator tube, then becomes standby states.
2-4. BD Service
This mode describes details in “3. BD SERVICE MODE” (page 
14).
2-5.  Tuner Factory Preset
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-6.  Digital Media Port Test
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-7.  Test Tone Mode
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-8. VACS Display
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-9. VACS On/off
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-10.  DSP Halt Mode
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
Page of 104