DOWNLOAD Sony AIR-SA15R / AIR-SA20PK Service Manual ↓ Size: 2.88 MB | Pages: 34 in PDF or view online for FREE

Model
AIR-SA15R AIR-SA20PK
Pages
34
Size
2.88 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
air-sa15r-air-sa20pk.pdf
Date

Sony AIR-SA15R / AIR-SA20PK Service Manual ▷ View online

AIR-SA15R
3
SECTION  1
SERVICING  NOTES
UNLEADED  SOLDER
Boards requiring use of unleaded solder are printed with the lead-
free mark (LF) indicating the solder contains no lead.
(Caution:  Some printed circuit boards may not come printed with 
the lead free mark due to their particular size)
 : LEAD  FREE  MARK
Unleaded solder has the following characteristics.
•  Unleaded solder melts at a temperature about 40 °C higher 
than ordinary solder.
 
Ordinary soldering irons can be used but the iron tip has to be 
applied to the solder joint for a slightly longer time.
 
Soldering irons using a temperature regulator should be set to 
about 350 °C.
Caution: The printed pattern (copper foil) may peel away if 
the heated tip is applied for too long, so be careful!
• Strong 
viscosity
 
Unleaded solder is more viscous (sticky, less prone to fl ow) 
than ordinary solder so use caution not to let solder bridges 
occur such as on IC pins, etc.
•  Usable with ordinary solder
 
It is best to use only unleaded solder but unleaded solder may 
also be added to ordinary solder.
NOTE  THE  S-AIR  COMMUNICATION  CONFIRMING
EZW-RT10 of the attachment is necessary for the confi rmation of 
S-AIR communication.
Confi rm S-AIR after inserting EZW-RT10 in the set (AIR-SA15R).
DIRECTION  OF  EZW-RT10  INSTALLATION
When EZW-RT10 is install with the S-AIR RX-IF board detached 
of the set, the label of EZW-RT10 is the under and install.
S-AIR RX-IF board
EZW-RT10
label
Power voltage indication
–Bottom View –
Model
Power voltage indication
US and Canadian models
AC: 120V - 60Hz 15W
AEP and UK models
AC: 230V - 50/60Hz 15W
MODEL  IDENTIFICATION
Ver. 1.2
– S-AIR RX-IF Board (Component Side) –
Suffix-12: 1-875-850-12
Suffix-13: 1-875-850-13
S-AIR  RX-IF  BOARD  DISCRIMINATION
In this set, the S-AIR RX-IF board has been changed in the mid-
way of production. Repair after distinguishing each type set to do-
ing the repair referring to the following.
AIR-SA15R
4
SECTION  2
GENERAL
This section is extracted 
from instruction manual.
Operations
6
Press 
/  repeatedly to select the desired 
option.
The default setting is underlined.
ALARM:
An alarm is output.
AUTO:
Sound from the connected S-AIR main unit is 
output. However, an alarm sounds in the following 
cases.
 When communication with the S-AIR main unit 
is cut off.
 When no sound is output from the S-AIR main 
unit or the audio signal level is too low.
 When the S-AIR main unit is not ready for 
playback at the set start time. Note that the alarm 
continues to sound even if the S-AIR main unit 
becomes ready after the start time has passed.
7
Press CLOCK/TIMER ENTER 
.
The display shows the timer settings.
8
If you selected “ALARM” in step 6, go to step 9. 
If you selected “AUTO” in step 6, prepare the sound 
source on the S-AIR main unit.
For details on preparing the sound source, refer to 
the Operating Instructions supplied with the S-AIR 
main unit.
9
Press 
  to turn off the unit.
The unit turns on about 45 seconds before the preset 
time.
If the unit is on at the preset time, the Daily Timer 
will not play.
To stop the alarm
Press any button.
To activate or check the timer again
1
Press CLOCK/TIMER MENU 
.
“SELECT” flashes in the display.
2
Press CLOCK/TIMER ENTER 
.
3
Press 
/  repeatedly to select “TIMER.”
4
Press CLOCK/TIMER ENTER 
.
To cancel the timer
1
Press CLOCK/TIMER MENU 
.
“SELECT” flashes in the display.
2
Press CLOCK/TIMER ENTER 
.
3
Press 
/  repeatedly to select “OFF.”
4
Press CLOCK/TIMER ENTER 
.
To change the setting
Start over from step 1.
Tip
The Daily Timer setting remains as long as the setting is not canceled 
manually.
Setting the clock
Use buttons on the unit to set the clock.
1
Turn on the unit.
Press 
 .
2
Select the clock set mode.
Press CLOCK/TIMER MENU . If the current 
mode appears on the display, press 
/
 repeatedly to select “CLOCK,” and then press 
CLOCK/TIMER ENTER .
3
Set the time.
Press 
/  repeatedly to set the hour, and 
then press CLOCK/TIMER ENTER . Use the 
same procedure to set the minute.
The clock settings are lost when you disconnect the 
power cord or if a power failure occurs.
Listening to the sound of the 
connected S-AIR main unit
You can use the S-AIR function to listen to the sound of 
an S-AIR main unit in a remote location.
1
Perform the procedure described in “Establishing 
the connection with an S-AIR main unit” and check 
that the S-AIR indicator 
 is lit.
2
Press S-AIR CH 
 repeatedly to select the desired 
S-AIR channel of the S-AIR main unit.
Wireless strength
The S-AIR channels that can be selected depend 
on the S-AIR main unit. For details, refer to the 
Operating Instructions supplied with the S-AIR main 
unit.
3
Press VOLUME +/
  to adjust the volume.
To operate the S-AIR main unit from the unit
You can perform the following operations using the 
buttons on the remote or unit.
To
Press
Start playback of a CD/DVD, 
etc.
 .
Stop playback of a CD/DVD, 
etc.
/CANCEL .
Pause playback of a CD/DVD, 
etc.
 .
Select a track, file or chapter 
of a CD/DVD, etc.
/ .
Select a preset station when 
listening to the radio
PRESET +/ 
 .
Change the FM/AM band 
when listening to the radio.
Hold down S-AIR 
CH  until the band 
changes.
Depending on the connected S-AIR main unit, 
the operation may differ. Refer to the Operating 
Instructions of the S-AIR main unit.
To listen with headphones
Connect headphones (not supplied) to the 
(headphones) jack located on the rear panel of the unit.
Note
The elapsed playing time or remaining playing time of the 
CD/DVD, etc. being played on the S-AIR main unit may not 
be displayed on this unit. In this case, “
.” appears.
Changing the display
To change the information on the display 
while the unit is on
Press DISPLAY  on the unit. Each time you press the 
button, the display changes as follows:
When the unit is connected to an S-AIR main unit:
Information of the connected S-AIR main unit
1)
Model name of the connected S-AIR main unit
2)
Clock
2)
 ...
When the unit is not connected to an S-AIR main unit:
“S-AIR” 
 “UNLINKED”
2)
 Clock
2)
 ...
1)
The displayed information depends on the connected S-AIR main 
unit. Up to 16 characters can be displayed.
2)
Displayed for about 8 seconds.
To turn off the display
When the unit is turned off, the clock is displayed. You 
can turn off the clock display to minimize the amount of 
power consumed (Power Saving Mode).
Press DISPLAY  on the unit when the clock is 
displayed. 
Press the button again to display the clock.
Note
The STANDBY indicator 
 on the unit lights up when the unit is 
off.
Using the Timers
The unit offers two timer functions. If you use the 
Daily Timer with the Sleep Timer, the Sleep Timer has 
priority.
Use buttons on the unit to set the timers.
Sleep Timer:
You can fall asleep to music. This function works even if 
the clock is not set.
Press SLEEP  repeatedly.
Note
Even if you set the timer, no sound is output from the unit if 
playback on the connected S-AIR main unit ends within the set time 
period or if communication with the S-AIR main unit is cut off.
Daily Timer:
You can wake up to the sound of the connected S-AIR 
main unit at a preset time.
Make sure you have set the clock.
1
Press VOLUME +/
  repeatedly to adjust the 
volume level while viewing the volume level 
indication on the display.
2
Press CLOCK/TIMER MENU 
.
3
Press 
/  repeatedly to select “TIMER,” 
then press CLOCK/TIMER ENTER 
.
“ON TIME” appears, and the hour indication flashes.
4
Set the time to start playing.
Press 
/  repeatedly to set the hour, and 
then press CLOCK/TIMER ENTER .
The minute indication flashes. Use the procedure 
above to set the minute.
5
Use the same procedure as in step 4 to set the time 
to stop playing.
Turning off the remote control 
function
In addition to the unit you already have, you can 
connect other S-AIR sub units to a single S-AIR main 
unit and use them together.
However, when using multiple S-AIR sub units near 
each other, all the S-AIR sub units may receive the same 
signal from the remote and the connected S-AIR main 
unit may not function properly. To prevent this, you can 
turn off the remote control function of the S-AIR sub 
units.
Use buttons on the S-AIR sub unit whose remote 
control function you want to turn off.
1
Press 
  to turn off the unit.
2
Press DISPLAY 
 repeatedly until the clock is 
displayed.
3
Press 
  while holding down CLOCK TIMER/
ENTER
.
“RMT OFF” appears in the display and the unit is 
turned on. If you try controlling the unit using the 
remote, “RMT OFF” appears in the display and the 
unit will not accept the signal from the remote.
To turn on the remote control function
Perform steps 1 and 3 above and check that “RMT ON” 
appears in the display.
Note
Even when the remote control function is turned off, 

and VOLUME +/
 on the remote will continue to 
function.
Unit (AIR-SA15R/Wireless Speaker System)
Remote (RM-ANU046)
AIR-SA15R
5
SECTION  3
DISASSEMBLY
•  This set can be disassembled in the order shown below.
3-1.  DISASSEMBLY  FLOW
3-2.  TOP PANEL BLOCK
 (Page 
6)
3-3.  HP BOARD, R_CON BOARD, 
 
FRONT PANEL BLOCK
 (Page 
7)
3-4. SPEAKER 
(6.5 
cm) 
 
(SP101: L-CH/SP201: R-CH)
 (Page 
7)
3-7.  AMP BOARD, LCD BOARD
 (Page 
9)
3-5.  S-AIR RX-IF BOARD, KEY BOARD, 
 MAIN 
BOARD
 (Page 
8) 
3-6. REG 
BOARD, 
 
POWER TRANSFORMER (PT901), 
 POWER 
CORD
 (Page 
9) 
SET
AIR-SA15R
6
Note: Follow the disassembly procedure in the numerical order given.
3-2.  TOP  PANEL  BLOCK
 grille frame assy
 four screws
 (B2.6)
 connector (CN310)
 connector (CN902)
 connector (CN312)
 flexible flat cable (9 core) 
 (CN316)
 flexible flat cable (11 core) 
 (CN315)
 connector (CN307)
 four screws
 (B2.6)
RT top panel block
RB connector (CN317)
Page of 34
Display

Sony AIR-SA15R / AIR-SA20PK Service Manual ▷ Download

  • DOWNLOAD Sony AIR-SA15R / AIR-SA20PK Service Manual ↓ Size: 2.88 MB | Pages: 34 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sony AIR-SA15R / AIR-SA20PK in PDF for free, which will help you to disassemble, recover, fix and repair Sony AIR-SA15R / AIR-SA20PK Audio. Information contained in Sony AIR-SA15R / AIR-SA20PK Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.