5
VC-M314HM
VC-MH834HM
(VC-MH834HM)
TOP CABINET
: Remove 4 screws 
1
.
FRONT PANEL
: Remove 2 screws 
2
 and 7clips 
3
.
ANTENNA
: Remove 1 screw 
5
 and 2 screws 
6
.
TERMINAL
COVER
MECHANISM/
: Remove 1 screw 
7
, 2 screws 
8
,
MAIN PWB
2 screws 
9
.
D
1
1
B
D
C
A
2
5
7
9
8
10
2
A
6
TOP CABINET
CASSETTE
HOUSING
ANTENNA
COVER
MECHA
CHASSIS
MAIN PWB
LED BOARD
PWB HOLDER
OPERATION PWB
FRONT PANEL
MAIN FRAME
TOP CABINET
FIXING ANGLE
HEAD AMP. SHIELD
3
3
B
6
VC-M314HM
VC-MH834HM
1. When removing the mechanism from the main PWB,
remove 1 screw 
1
 from behind of main PWB.
Remove the FFC cable (AA,AD,AH) 
2
 which con-
nects the PWB and the mechanism.
Take out vertically the mechanism so that it does not
damage the adjacent parts.
2. Removing the mechanism and cassette housing.
Remove 2 screws 
3
 fixing the cassette housing to the
mechanism, and remove the cassette housing.
2-2  DISASSEMBLING THE MECHANISM/MAIN PWB ASSEMBLY
CASSETTE
HOUSING
MAIN PWB
MECHANISM CHASSIS
3
2
1
#
(Mark #:VC-MH834HM only)
7
VC-M314HM
VC-MH834HM
cassette housing. (Conditions: When mechanism and
PWB have been installed)
2. Mechanical initial setting
Feed the pulley feed gear of loading motor with screw
driver. After ascertaining the return to the initial set posi-
tion (*1) install the cassette housing in the specified
position. (This method is applied only for the mechanism.)
PARTS WHICH NEED PARTICULAR CARE
When installing the mechanism chassis on the PWB unit,
take care so as to prevent deformation due to contact of
mechanism chassis with REC TIP SW.
Pulley feed gear
Screwdriver
Casecon
drive gear
Drive angle of
cassette housing
Tilt mark (*1)
INSTALLING THE CASSETTE HOUSING
When the cassette housing is installed on the mechanism,
the initial setting is essential condition.
There are two initial setting methods, namely electrical
and mechanical.
1. Electrical initial setting
So as to perform initial setting of mechanism execute the
Step 1 of Installation of cassette housing. After ascertain-
ing the return to the initial setting position (*1) install the
2-3  CARES WHEN REASSEMBLING
INSTALLING THE MECHANISM ON PWB
Lower vertically the mechanism, paying attention to the
mechanism edge, and install the mechanism with due
care so that the parts are not damaged. So as to fix the
mechanism to the main PWB install two housings. (Fit the
antenna cover to one of them. For other, fix the vicinity of
loading motor and solder joint side of main PWB.) Con-
nect again the FFC cable (AA-MH, AD-ME, AH-MZ)
between the mechanism and the main PWB.
START SENSOR
AL CONNECTOR
AE CONNECTOR
END SENSOR
REC TIP SW
(Mark # :VC-MH834HM only)
#
#
AC CONNECTOR
8
VC-M314HM
VC-MH834HM
3. FUNCTION OF MAJOR MECHANICAL PARTS (TOP VIEW)
No.
Function
No.
Function
1
Full erase head
2
Supply pole base ass’y
3
Tension arm ass’y
4
Idler wheel ass’y
5
Pinch drive lever ass’y
6
Supply reel disk
7
Supply main brake ass’y
8
Take-up main brake ass’y
9
Pinch drive cam
10
A/C Head ass’y
11
Reverse guide lever ass’y
12
Casecon drive gear
13
Take-up reel disk
14
Pinch roller lever ass’y
15
Drum ass’y
16
Loading motor
17
Drum motor
18
Take-up pole base ass’y
17
15
10
11
5
9
14
12
8
16
13
4
6
2
7
3
1
18
Page of 99