Sharp VC-A215HM (serv.man16) Service Manual / Technical Bulletin ▷ View online
VCR2000 04 02
Month of Issue:
April 2000
Classification:
White
VIDEO TECHNICAL BULLETIN
Page 1 of 1
Sharp Electronics (UK) Limited
Reference AVW14042000-1
Revision 1
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
Red – Carry out on all units
MODELS
VCT310HM
VCT510HM
VCA30HM
VCA40HM
VCA50HM
VCA615HM
VCA81HM
VCA215HM
VCA55HM
VCA63HM
VCH84HM
VCH86HM
SYMPTOM Unit laces up in play or record mode then unlaces after a few seconds.
CAUSE
Loss of the drum FG pulse resulting in no head-switching signal.
ACTION
Replace the drum motor assembly using the part number given in the respective
Service Manual.
Service Manual.
Display