DOWNLOAD Sharp PZ-50HV2E (serv.man8) Service Manual ↓ Size: 141.58 KB | Pages: 19 in PDF or view online for FREE

Model
PZ-50HV2E (serv.man8)
Pages
19
Size
141.58 KB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD / Adjustment procedures
File
pz-50hv2e-sm8.pdf
Date

Sharp PZ-50HV2E (serv.man8) Service Manual ▷ View online

25
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
Timing Adjustment of X and Y DRIVE Assys Control Signal 
As for this adjustment, adjustment with set state is difficult.
Therefore replace it every Assy when replacing the pulse module.
Adjustment VR
Test pin for adjustment and measurment
Display a SUSOUT waveform
Power ON and display a SUSOUT 
waveform
Display a SUS-D waveform
Display a SUS-U waveform
Power ON and 
display a SUS-D waveform
Display a SUS-U waveform
Measuring points of waveform
are refered to next page.
Power ON
Black Mask Screen
Coarse adjustment of
SUS-U, SUS-B, SUS-G
SUS-D adjustment
Adjust the waveform to 20-25ns.
SUS-U adjustment
Adjust the waveform to 20-25ns.
Power OFF
Compare waveform, 
and do harmonize 
almost?
Yes
No
Adjust VR resistance value
of SUS-B and SUS-G to match
VR resistance value of SUS-D
within 
±
 2
.
Adjust VR resistance value
of SUS-B and SUS-G to match
VR resistance value of SUS-D
within 
±
 2
.
Power OFF
Adjustment end
SUS-D readjustment
Adjust the waveform to 20-25ns.
SUS-U readjustment
Adjust the waveform to 20-25ns.
X DRIVE
Y DRIVE
SUS-U
VR3203
VR2204
SUS-D
VR3202
VR2203
SUS-B
VR3201
VR2202
SUS-G
VR3200
VR2201
Pulse Module
X DRIVE
Y DRIVE
Upper
Lower
Upper
Lower
SUSOUT
K3105
K3106
K2212
K2203
SUS-U
K3200
K3204
K2220
K2224
SUS-D
K3108
K3205
K2207
K2225
Purpose
• Pulse module loads in DRIVE Assy as one of heat measures of DRIVE Assy. Adjust the drive timing of the pulse module 
driving parallel with VR.
• Pulse module has each peculiar delay time. Readjustment is necessary when replaced the pulse module in the X and 
Y DRIVE Assys.
Adjustment Method
CR delay circuit is each inserted on signal path of four control signals (SUS-U, SUS-B, SUS-D, SUS-G) driving 
the pulse module.
Quantity of delay can adjust pulse module of one side with VR.
Adjust VR while measuring a waveform of the pulse module, and match a timing.
Adjustment Procedure
26
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
Use this sustain pulse
and adjust.
Magnify 6SF block
Magnify the adjustment waveform
Magnify 6SF block
CH1 : Y SUSOUT Under (K2203), 50V/div
CH2 : Y SUSOUT Upper (K2212), 50V/div
CH4 : YPR-U1 (K2038)- Trigger, 5V/div
Trigger : 2msec delay
CH1 : Y SUSOUT Under (K2203), 50V/div
CH2 : Y SUSOUT Upper (K2212), 50V/div
CH4 : YPR-U1 (K2038)- Trigger, 5V/div
Trigger : 2msec delay
CH1 : X SUSOUT Under (K3106), 50V/div
CH2 : X SUSOUT Upper (K3105), 50V/div
CH4 : YPR-U1 (K2038)- Trigger, 5V/div
Trigger : 2msec delay
Y DRIVE SUSOUT waveform
X DRIVE SUSOUT waveform
Measuring point of waveform
Waveform coarse adjustment
Measuring Waveform of Pulse Module Timing Adjustment
Timing adjustment of the pulse module control signal adjusts with the sustain pulse of eighth pulse (X DRIVE) and 
the ninth pulse (Y DRIVE) from the back of 6SF.
Measure the SUSOUT waveform
1SF
2SF 3SF 4SF 5SF 6SF 7SF
1ms/div
5
µ
s/div
1SF
2SF 3SF 4SF 5SF 6SF 7SF
1ms/div
5
µ
s/div
• Perform adjustment of waveform with a black mask screen.
• It is easy to adjust when turned field AB offset to OFF (RS-232C
  command: OCN) in adjustment.
Note:
• Sampling rate of oscilloscope sets it more than 500MS/s in order
  to perform ns order adjustment.
• Collecting calibration of probe before adjustment by all means.
• Connect GND of probe measuring waveform to SUSGND terminal
  by all means.
• Precise waveform is not displayed, and an adjustment gap may
  occur that does not collect GND properly.
When took waveform be each drive Assy unit, measure it at the 
fourth sustain pulse from the back except for a large width sustain 
pulse.
Therefore, when measured both waveform of the X and Y drives 
together, it becomes the sustain pulse of 8 and 9 pulses from the 
back.
When there is a gap with waveform of CH1 / CH2 of the part which 
enclosed in the following circle, adjust required VR to overlap the 
waveform.
Adjust with SUS-B
Adjust with SUS-U
Adjust with SUS-G
1ms/div
500ns/div
Use this sustain pulse
and adjust.
27
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
CH1 : Y SUSOUT Under (K2203), 50V/div
CH2 : Y SUSOUT Upper (K2212), 50V/div
CH4 : YPR-U1 (K2038)- Trigger, 5V/div
Trigger : 2msec delay
CH1 : Y SUS-D Under (K2225), 50V/div
CH2 : Y SUS-D Upper (K2207), 50V/div
CH4 : YPR-U1 (K2038)- Trigger, 5V/div
Trigger : 2msec delay
CH1 : Y SUS-U Under (K2224), 50V/div
CH2 : Y SUS-U Upper (K2220), 50V/div
CH4 : YPR-U1 (K2038)- Trigger, 5V/div
Trigger : 2msec delay
SUS-D Adjustment (Y DRIVE)
Waveform Confirmation in Adjustment completion
Measure the SUSOUT waveform
SUS-U Adjustment (Y DRIVE)
1ms/div
5
µ
s/div
1ms/div
5
µ
s/div
1ms/div
500ns/div
1ms/div
10ns/div
1ms/div
500ns/div
Confirm it to waveform of CH1 / CH2 of the part which enclosed in 
the following circle whether there is not a large gap.
(A gap of the quantity that shifts 20nS and adjusted remains.)
When adjust in the power supply ON state, change so that the 
quantity of gap that adjusted by temperature-rise of the pulse 
module becomes small.
Therefore, perform high power OFF (RS-232C command: DRF) 
except measurement time of waveform when adjusts, and 
adjustment error by temperature-rise does not occur.
20 - 25ns
1ms/div
200ns/div
Lower PM
Upper PM
Lower PM
Upper PM
1ms/div
10ns/div
20 - 25ns
Caution:
Not absolutely mistaking upper
and lower of waveform.
Magnify 6SF block
Magnify 6SF block
Magnify 6SF block
Magnify 6SF block
Magnify the adjustment waveform
Magnify 6SF block
Magnify 6SF block
Magnification
Magnification
Magnification
Magnification
28
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
SUS-B Ground Timing Adjustment
It is necessary to readjust this adjustment when replaced the X or Y DRIVE Assy and the pulse module.
Measurement point and method
Measurement point of waveform of X and Y DRIVE Assy in timing adjustment is test pin of SUSOUT of the pulse module of
bottom of the main unit.
X DRIVE Assy : K3106     Y DRIVE Assy : K2203
Measurement screen : White mask
The measurement is easy to perform when turns field AB alternation to OFF. (RS-232C command: OCN)
Measure a sustain pulse of the fourth pulse (X DRIVE) and the fifth pulse (Y DRIVE) from the back of the fourth FS, and 
adjust.  In the start section of this sustain pulse, waveform has inflection point with the timing when SUS-B becomes ON. 
Adjust so that the voltage of this inflection point is the nearest to 150V and do not become less than 150V.
Adjustment parameter
X DRIVE: XSUSB (RS-232C command : XSB)
Y DRIVE: YSUSB (RS-232C command : YSB)
Note:
• Connect GND of probe measuring waveform to SUSGND terminal by all means.
• Precise waveform is not displayed, and an adjustment gap may occur that does not collect GND properly.
Waveform in the measurement
CH1 : Y SUSOUT (K2203), 50V/div
CH2 : X SUSOUT (K3106), 50V/div
CH4 : YPR-U1 (K2038)- Trigger, 5V/div
Trigger : 2msec delay
Rst
1ms/div
X
X
X
X
X
X
Y
Y
Y
Y
Y
Y
5
µ
s/div
Magnify 4SF block
Measure a waveform of this section and adjust.
Magnify the fourth pulse sustain pulse (XSUSOUT waveform) from the back of the above waveform.
1SF
2SF
3SF
4SF
OK
NG
150V Line
GND
50V/div
100msec/div
50V/div
100msec/div
150V Line
This broken section moves by
changing the adjustment 
parameter.
Become less than 150V.
 NG
Page of 19
Display

Click on the first or last page to see other PZ-50HV2E (serv.man8) service manuals if exist.