28
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
SUS-B Ground Timing Adjustment
It is necessary to readjust this adjustment when replaced the X or Y DRIVE Assy and the pulse module.
Measurement point and method
Measurement point of waveform of X and Y DRIVE Assy in timing adjustment is test pin of SUSOUT of the pulse module of
bottom of the main unit.
X DRIVE Assy : K3106     Y DRIVE Assy : K2203
Measurement screen : White mask
The measurement is easy to perform when turns field AB alternation to OFF. (RS-232C command: OCN)
Measure a sustain pulse of the fourth pulse (X DRIVE) and the fifth pulse (Y DRIVE) from the back of the fourth FS, and 
adjust.  In the start section of this sustain pulse, waveform has inflection point with the timing when SUS-B becomes ON. 
Adjust so that the voltage of this inflection point is the nearest to 150V and do not become less than 150V.
Adjustment parameter
X DRIVE: XSUSB (RS-232C command : XSB)
Y DRIVE: YSUSB (RS-232C command : YSB)
Note:
• Connect GND of probe measuring waveform to SUSGND terminal by all means.
• Precise waveform is not displayed, and an adjustment gap may occur that does not collect GND properly.
Waveform in the measurement
CH1 : Y SUSOUT (K2203), 50V/div
CH2 : X SUSOUT (K3106), 50V/div
CH4 : YPR-U1 (K2038)- Trigger, 5V/div
Trigger : 2msec delay
Rst
1ms/div
X
X
X
X
X
X
Y
Y
Y
Y
Y
Y
5
µ
s/div
Magnify 4SF block
Measure a waveform of this section and adjust.
Magnify the fourth pulse sustain pulse (XSUSOUT waveform) from the back of the above waveform.
1SF
2SF
3SF
4SF
OK
NG
150V Line
GND
50V/div
100msec/div
50V/div
100msec/div
150V Line
This broken section moves by
changing the adjustment 
parameter.
Become less than 150V.
 NG
29
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
VR2702
(IC5V_ADJ)
VR2201
(SUS_G_ADJ)
VR2202
(SUS_B_ADJ)
VR2203
(SUS_D_ADJ)
VR2204
(SUS_U_ADJ)
K2205
K2004
K2001
K2002
K2003
K2005
K2009
K2013
K2010
K2011
K2226
(SUS_U)
K2212
(SUSOUTB)
K2225
(SUS_D)
K2224
(SUS_U)
K2203
(SUSOUTA)
K2227
(SUS_D)
K2218
(1/2 VSUS)
K2214
(SUS_G)
K2215
(SUS_B)
K2217
(SUS_U)
K2716
(VH)
K2720
(PSUS)
K2717
(VH CONT)
K2216
(SUS_D)
VR2703
(VH_ADJ)
K2715
(YDC_DC_PD)
K2718
(VH UVP)
K2719
(VH OVP)
K2708
(VOFS)
K2705
(SUSGND)
K2702
(VSUS)
K2709
K2703
(SUSGND)
VR2701
K2222
K2211
K2710
(VOFS)
K2712
(VOFSUVP)
K2221
(+15V)
K2045
K2049
K2047
K2044
K2050
K2048
K2046
K2012
(PN MUTE)
K2038
(YPR_U1)
K2040
(YCP_MSK)
K2053
(SOFT_D)
K2041 (OFS)
K2039 (YSUS_MSK)
K2037 (YSUS_G)
K2028 (YSUS_U)
K2021
(YPR_U2)
K2029
(YSUS_D)
K2027
(YSUS_B)
K2024
(DGND)
K2101
(DEW_DET)
K2043
(DGND)
K2008
(DGND)
K2007
(DGND)
K2006
(+5V)
K2707
(IC5V)
K2714
(GNDHS)
K2704
(VF-)
K2701
(VF+)
K2706
(+14V)
K2711
(-8V)
K2713
(IC5V UVP)
VR3200
(SUS-G)
VR3201
(SUS-B)
VR3202
(SUS-D)
VR3203
(SUS-U)
K3103
(VCP_PD)
K3104
(+5V)
K3001
(+5V)
K3003
(XSUS-B)
K3015
(XSUS-MSK)
K3017
(XCP-MSK)
K3012
(XSUS-D)
K3014
(XNR-D1)
K3025
K3007
K3010
(XNR-U)
K3008
(PN_MUTE)
K3021
K3022
K3011
K3704
(VRN. CNT)
K3703
(SUS. GND)
K3701
(VSUS)
K3029
K3006
K3009
K3030
K3705
VRN UVP)
K3706
(X DC-DC PD)
K3708
(VRN_OVP)
VR3701
(VRN. ADJ)
K3707
(VRN)
K3702
(SUS. GND)
K3213
(1/2VSUS)
K3214
(SUSGND)
K3205
(SUS_D)
K3204
(SUS_U)
K3106
(SUSOUT_B)
K3102
(XNR_PD)
K3203
(1/2VSUS)
K3201
(SUSGND)
Adjusting Points
Y DRIVE Assy
X DRIVE Assy
K3108
(SUS_D)
K3200
(SUS_U)
K3105
(SUSOUTA)
K3004 (XSUS-U)
K3013 (XSUS-G)
K3018 (XNR-D2)
30
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
RS-232C Command
Connection
As for PZ-50HV2 system, the 232C control of the panel control item is possible by a single state.
However, the following exclusive use communication jig is necessary.
 Be careful so that can not use a DSUB 9-pin in the rear panel of the AVC System.
38400 bps is fixed.
Communication baudrate
Jig Schematic Diagram
PDP rear view
DVI (Video line):
Input optional video from the 
signal source with the DVI 
output.
Input timing is as follows.
Communication line:
Connect a system cable.
PC for control
Connect to DSUB 9-pin
DSUB 9-pin straight cable
Exclusive use 
communication jig
AC-DC adapter
(9V or 12V output)
DVI input timing
XGA60 (VESA conformity)
CLK
65MHz
H total
1344 clk
H disp
1024 clk
H sync
136 clk
H BP
160 clk
V total
806 line
V disp
768 line
V sync
6 line
V BP
29 line
fH
48.363 kHz
fV
60.004 Hz
COMMAND
CN1
AKP1201
CN2
AKB1099
CN4
AKP1205
CN3
AKP1194
CN5
B3B-PH-SM3-TBB
R4
R
C1
1/50
IC1
DS14C232CM-TBB
IC2
PQ05DZ51-TLB
100
R5
100
R8
GND
9.3V
D1
D1FS4-TRB
D2
D1FS4-TRB
9V
NC
GND
G_JIGU10
100
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
C1+
V+
C1-
C2+
C2-
V-
DOUT2
RIN2
VCC
GND
DOUT1
RIN1
ROUT1
DIN1
DIN2
ROUT2
C3
1/50
C5
47/16
C7
47/16
C8
0.1
C4
0.1
C2
1/50
C6
R14
100k
1/50
L
G_JIGU10
R15
100k
R12
2.2k
R11
2.2k
R16
10k
R17
10k
R1
1k
R3
0
R2
0
C9
0.1
G_JIGU10
C10
47/16
VIN
VO
VC
GND
NC
R6
100
R13
0
R7
100
V_JIGU10
R9
0
R10
SP_L
CSEN1
CSEN2
CCKM
GND
SMPOW
SP_R
SENCE
GND
RXD0_M
SP_L
GND
SRST
FLASH_W
GND
SR_UP
SR_DOWN
SP_R
GND
TXD0_M
0
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Page of 19
Display

Click on the first or last page to see other PZ-50HV2E (serv.man8) service manuals if exist.