21
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
Display example of the thirteenth page
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
V I
PC
D
D
E
E
O
NEGAT
2
1 / 1 3
PUT1 No S I G
N
I
DR
0 0
VE MO
I
DE
DR VE MO
DE
MO
I
VE
I
PATTE N
R
ENHAN E
C
BR I GHT
FREQ
MASK
FULL MASK
MASK
V
0 3
OFF
OFF
OFF
OFF
5 0
No.
Item
Adjustable Range
Shipping Setting
Storage Place
1
Drive mode selection at VIDEO
0 to 5
0
PDP
2
Drive mode selection at PC
0 to 5
3
PDP
3
Negative positive inversion mode
OFF/ON
OFF
PDP
4
Bright enhance
OFF/ON
OFF
None
5
Refresh rate at mask signal generation
50/60/70
None
6
Pattern mask signal generation
OFF/
OFF
PDP
7
Full mask signal generation
OFF/
OFF
PDP
Caution in the mask (generation test signal screen in the PDP inside) signal generation:
• A pattern mask and a full mask can use only either.
  Therefore, turn a full mask to OFF when uses a pattern mask. Also turn a pattern mask to OFF when uses a full mask.
• A pattern mask and a full mask are test signal screens occurring together in the PDP inside. Therefore, in the mask signal generation, it 
  cannot confirm video inputting from OSD and the outside.
  When release mask setting or change of each setting or perform the confirmation of the adjustment or external input signal, perform key 
  operation of the main unit button or the remote control unit.
  When operated something, stop the generation of the mask signal just after that for two seconds. Therefore, modification and adjustment of 
  each setting and confirmation of the external input signal are possible.
 : Be careful so that there is the case that page constitution is different.
22
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
ADJUSTMENT REQUIRED WHEN THE SET IS REPAIRED OR REPLACED
DIGITAL VIDEO Assy
When repaired
No adjustment required.
MR INTERFACE Assy
• Set slide SW according to page 244.
When replaced
SW POWER SUPPLY Module
When replaced
No adjustment required.
• Remove IC1204 (24LC04(1) SN-TBB) from the former 
PC Board to replace, and install it to the new PC Board.
Y DRIVE Assy
When repaired
When replaced
1. VOFS/VH/IC5V voltage adjustment
2. Timing adjustment of pulse module
1. SUSB ground timing adjustment
2. Panel white balance adjustment
1. SUSB ground timing adjustment
2. Panel white balance adjustment
X DRIVE Assy
When repaired
When replaced
1. VRN voltage adjustment
2. Timing adjustment of pulse module
DIGITAL VIDEO
Assy
X DRIVE
Assy
Y DRIVE
Assy
MR INTERFACE
Assy
SW POWER SUPPLY
Module
Fig. 1  PC Board Location (rear side view)
23
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
VOFS (Offset voltage) adjustment
Method 1
1. Write down a adjustment value of VOFS ADJ in the factory mode.
2. Set this adjustment value to center (128).
3. Adjust VR2701 so that the voltage between K2701 (VOFS) and K2703 (SUS GND) becomes
45V.
4. Return it to the value that wrote down a adjustment value of V-OFFSET in step 1.
Method 2
1. Read the adjustment value of VOFS ADJ in the factory mode.
2. Adjust VR2701 so that the voltage between K2710 (VOFS) and K2703 (SUS GND) becomes
following voltage 
±
 0.5V.
VH (voltage for scan IC) Adjustment
Adjust so that the voltage between K2716 (VH) and K2720 (PSUS) becomes 103V 
±
 0.5V.
PSUS (=GNDH) is a floating GND and the electric potential is different from that of chassis 
GND. Be sure not to short-circuit PSUS (=GNDH) and another GND, because that may 
damage the unit.
The symptom is case of mis-adjustment
If the VH adjustment is not performed properly, dots like blinking luminance points appear. If 
deviated greatly from the right adjustment point, panel will light white.
Input Signal
Adjusting Point
Adjusting Method
White 100%
VR2701 (VOFS)
(Y DRIVE Assy)
VR2703 (VH)
(Y DRIVE Assy)
IC5V Adjustment
Adjust so that the voltage between K2707 (IC5V) and K2720 (PSUS) becomes 5.0V 
±
 0.1V.
PSUS (=GNDH) is a floating GND and the electric potential is different from that of chassis 
GND. Be sure not to short-circuit PSUS (=GNDH) and another GND, because that may 
damage the unit.
The symptom is case of mis-adjustment
If the VOFS Voltage adjustment is not performed properly, dots like blinking luminance points 
appear. If deviated greatly from the right adjustment point, panel will light white.
VR2702 (IC5V)
(Y DRIVE Assy)
Note : Be sure to measure between specified test points.
Input
Command
DAC
Output
Setting 
Voltage
Input
Command
DAC
Output
Setting 
Voltage
VOF000
0.4
25
VOF134
2.599212598
45.94488
VOF006
0.4984375
25.9375
VOF141
2.71496063
47.04724
VOF013
0.61328125
27.03125
VOF147
2.814173228
47.99213
VOF019
0.71171875
27.96875
VOF153
2.913385827
48.93701
VOF026
0.8265625
29.0625
VOF160
3.029133858
50.03937
VOF032
0.925
30
VOF166
3.128346457
50.98425
VOF038
1.0234375
30.9375
VOF172
3.227559055
51.92913
VOF045
1.13828125
32.03125
VOF179
3.343307087
53.0315
VOF051
1.23671875
32.96875
VOF185
3.442519685
53.97638
VOF058
1.3515625
34.0625
VOF191
3.541732283
54.92126
VOF064
1.45
35
VOF198
3.657480315
56.02362
VOF070
1.5484375
35.9375
VOF204
3.756692913
56.9685
VOF077
1.66328125
37.03125
VOF211
3.872440945
58.07087
VOF083
1.76171875
37.96875
VOF217
3.971653543
59.01575
VOF090
1.8765625
39.0625
VOF223
4.070866142
59.96063
VOF096
1.975
40
VOF230
4.186614173
61.06299
VOF102
2.0734375
40.9375
VOF236
4.285826772
62.00787
VOF109
2.18828125
42.03125
VOF242
4.38503937
62.95276
VOF115
2.28671875
42.96875
VOF249
4.500787402
64.05512
VOF122
2.4015625
44.0625
VOF255
4.6
65
VOF128
2.5
45
ADJUSTMENT
VOFS/VH/IC5V Voltage Adjustment
24
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
Input Signal
Adjusting Point
Adjusting Method
White 100%
REF_DIG mode
in Factory mode
XSUSB ADJ
YSUSB ADJ
X-SUS-B, Y-SUS-B Adjustment
Set to the indicated value with the remote control unit.
(Refer to "Timing adjustment of control signal of X and Y Drive Assys".)
Input Signal
Adjusting Point
Adjusting Method
White 100%
VR3701 (VRN)
(X DRIVE Assy)
VRN (minus reset voltage adjustment)
Adjust so that the voltage between K3707 (VRN) and K3702 (SUS-GND) becomes
-300V 
±
 1.0V.
Input Signal
Adjusting Point
Adjusting Method
Reference : Adjustment values using the Media color-difference meter (CA-100)
Adjust the parameter in the OFFSET-DIGITAL of factory mode as follows;
PANEL R-HIGH
PANEL B-LOW
In this time, dispay uses the mask (MASK04) of factory mode.
Sustain Pulse Waveform Adjustment
VRN Voltage Adjustment
Panel White Balance Adjustment
MASK Left Side
x
295
y
306
MASK Right Side
291
300
When perform the various adjustment by RS-232C control, execute a "DM0" command (release the limit of pulse number) 
beforehand.
After the adjustment completion, execute a "DM 3" command (Limit of pulse number: 64%, shipping state) by all means.