16
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
ADJUSTMENT PROCEDURES
SERVICE FACTORY MODE
Remote Control Unit Operation in The Service Factory Mode
Operate the service factory mode with the remote control unit of accessory of the AVC System.
Please perform the adjustment by operating the following keys.
Service factory mode uses an OSD function of the AVC System.
Perform the adjustment and setting in the state that this unit and Media Receiver are connected by the system.
Plasma display cannot use a factory mode by being simple.
Remote 
Control Key
Function
CH
'
 key
One line moves the selection cursor of the adjustment item up.
CH
"
 key
One line moves the selection cursor of the adjustment item down.
VOL     + key
+1 raises a adjustment value
VOL      – key
–1 reduces a adjustment value
'
 key
Perform page down (previous page)
"
 key
Perform page up (next page)
\
 key
–10 reduces a adjustment value
|
 key
+10 raises a adjustment value
Model: PZ-50HV2/2E
TV
ANT-A/B
INPUT
SURROUND
FRONT
TWIN
MODE
AV
POWER
MTS
CC
PICTURE
SELECT
SUB
TWIN CH
+
FREEZE
MODE
VOL
CH
MUTE
MENU
TV/SAT/DVD
FAVORITE CH
RECEIVER
DTV/DVD TOP
SOURCE
DTV/SAT
DTV/SAT
VCR REC
A
B
C
D
RETURN
MENU
POWER
SET/
ENTER
MENU
GUIDE
INPUT
VOL–
VOL+
INFO
VIEW
SLEEP
LEARN
EDIT/
ENT
FLASHBACK
DISPLAY
INPUT
TV
VCR
CBL
/SAT
/DTV
DVD
/LD
1
2
3
4
5
6
7
8
9
100
0
POWER
Model: PZ-50HV2U
17
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
1. How to Enter the Service Factory Mode
Perform the following operation by the remote control unit for less than 3 seconds.
• Press the "MENU" key
• Press the "ENTER" key
• Press the "0" key
Press the "Factory" key (Note 1)
Switch a page 
with "
'
" and "
"
" keys.
Press the "Factory" key (Note 1)
Press the "    (POWER)" key (POWER OFF)
System standby state
Confirm that the plasma display and the AVC System turned on together and a 
system cable is connected properly.
Image receiving state
Page 1/13
General information of the Plasma Display and AVC System
Service Factory Mode
Page 2/13 to 9/13
Adjustment and setting item of the AVC System
Page 11/13 to 13/13
Adjustment and setting item of the Plasma Display
Note 1: When use the adjustment exclusive use remote control unit with a [AA5F] code.
 : Be careful so that there is the case that page constitution is different.
18
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
2. General Information of the Plasma Display and AVC System
Display example of the first page
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
CENTE
1 / 1 3
R Ve r s
OSD Ve r s i o n
CV I C Ve r s i o n
TTXP Ve r s i o n
i on
MON I TOR Ve r s i on
Mod e l S l e
e
c t
i n
Ma
Mod e l S l e
e
c t AV
Mod e l S l e
e
c t
Ce n t e r
c u
A
t i me
MON I TOR
RESET
RESET
OFF
RESET
OFF
OFF
+
0
0
4
2 8
F 6 9 1 1 0
TTX
R
P G
W2 0 0 /
1 0 9
0
0 0
9 :
1 2
/
X2 0 0 /
1 0 9
0
0 7
9 :
1 2
/
V2 0
0 6 1
0 /
1 0 9
0
1 0
9 :
1 2
/
MR O D
S
2
0
1 0
9
A
/
/
0 1
0
MR M I
A N
0 0
2
1
E
- 0 5
- 0 0
PANEL Ve r s i on
FLASH Ve r s i on
MON I TOR Mo de l
Mon i t o r Ac u t i me
4 7
H
4 2 M
H
4 1 M
1 6
0 1
Pu l s e Ac u t i me
1 6 4
Se n s o r e Temp
0
2 5 H
9 /
/
NP
I
U
S
1
G
I
No
T
No.
Item
Explanation
1
Main software version information of the AVC System
2
OSD version information of the AVC System
3
IP/resize IC control software version information of the AVC 
System
4
Text microcomputer software version information of the 
AVC System
5
Module microcomputer software version information of the PDP
6
Panel microcomputer version information of the PDP
7
Panel flash ROM version information of the PDP
8
PDP model information
01: PIONEER 50 inches,  02: PIONEER 43 inches, 
11: SHARP 50 inches,  12: SHARP 43 inches
9
AVC System model information
10
AVC System model information
11
PDP destination information
0: All SHARP destinations, Japanese and North America destinations of 
PIONEER, 3: European and general destinations of PIONEER
12
Temperature information of panel temperature sensor on 
the PDP
This is internal temperature information. This is not establishment 
environment temperature.
13
AVC System accumulation operating time
14
AVC System accumulation operating time reset
Turn the display to [ON] by pressing the "VOL +" key, then it becomes [0H] 
when pressing the "ENTER" key.
15
PDP accumulation operating time
16
PDP accumulation operating time reset
Turn the display to [ON] by pressing the "VOL +" key, then it becomes [0H] 
when pressing the "ENTER" key.
17
PDP accumulation pulse number
Real accumulation pulse number becomes "indicated value *10,000,000 pulse".
Reference
18
PDP accumulation pulse number reset
Turn the display to [ON] by pressing the "VOL +" key, then it becomes [0] 
when pressing the "ENTER" key.
 : Be careful so that there is the case that page constitution is different.
19
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
3. Adjustment and Setting Item of the Plasma Display
Display example of the eleventh page
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
MNTR
1
1 / 1 3
PUT1 No S I G
N
I
V5 0
0 2
WB
MNTR V6 0
0 1
WB
MNTR PC
0 1
WB
MNTR R H
2 5 5
I GH1
MNTR R H
2 5 5
I GH2
MNTR G H
2 5 5
I GH2
MNTR B H
2 5 4
I GH2
MNTR G H
2 5 5
I GH1
MNTR B H
2 5 4
I GH1
MNTR R L
5 1 0
OW1
MNTR G L
5 0 9
OW1
MNTR B L
5 1 2
OW1
MNTR R L
5 1 0
OW2
MNTR G L
5 1 1
OW2
MNTR B L
5 1 2
OW2
No.
Item
Adjustable Range
Shipping Setting
Storage Place
1
PDP_W/B table selection at VIDEO 50Hz
1 or 2
2
PDP
2
PDP_W/B table selection at VIDEO 60Hz
1 or 2
1
PDP
3
PDP_W/B table selection at PC
1 or 2
1
PDP
4
RED_GAIN of PDP_W/B table 1
0 to 255
Factory adjustment value
PDP
5
GREEN_GAIN of PDP_W/B table 1
0 to 255
Factory adjustment value
PDP
6
BLUE_GAIN of PDP_W/B table 1
0 to 255
Factory adjustment value
PDP
7
RED_OFS of PDP_W/B table 1
0 to 999
Factory adjustment value
PDP
8
GREEN_OFS of PDP_W/B table 1
0 to 999
Factory adjustment value
PDP
9
BLUE_OFS of PDP_W/B table 1
0 to 999
Factory adjustment value
PDP
10
RED_GAIN of PDP_W/B table 2
0 to 255
Factory adjustment value
PDP
11
GREEN_GAIN of PDP_W/B table 2
0 to 255
Factory adjustment value
PDP
12
BLUE_GAIN of PDP_W/B table 2
0 to 255
Factory adjustment value
PDP
13
RED_OFS of PDP_W/B table 2
0 to 999
Factory adjustment value
PDP
14
GREEN_OFS of PDP_W/B table 2
0 to 999
Factory adjustment value
PDP
15
BLUE_OFS of PDP_W/B table 2
0 to 999
Factory adjustment value
PDP
Caution in the PDP W/B (No.4 to 15) adjustment:
Adjustment value is reflected without relation in input signal during adjustment to the actual PDP.
For example, when operate a adjustment value of [MNTR HIGH1] during PAL input, switch to the adjustment value operation of W/B table 1 
while displaying PAL in the actual PDP.
This is temporary.
After adjustment, it becomes the W/B table 2 operation in the PAL input after restarted in the normal mode. It becomes an operation of the W/B 
table 1 adjustment value after adjustment in the NTSC input.
As for the above example, table selection (No. 1 and 2) becomes the shipping setting.
 : Be careful so that there is the case that page constitution is different.
Page of 127