Sharp LC-60LE855E (serv.man3) Service Manual ▷ View online
LC-60LE855E/K,60/70LE857E/RU,858E,70LE857K
5 – 17
10. Video signal adjustment procedure
The adjustment process mode menu is listed in Section 5.
Signal generator level adjustment check. (Adjustment to the specified level)
10.1. Entering the adjustment process mode
Enter the adjustment process mode according to Section 2.
10.2. PAL signal adjustment
* ATTENTION: Please execute [10.3. TUNER adjustment] afterwards if you adjust [10.2. PAL signal adjustment] after all adjustments are
completed.
10.3. TUNER adjustment
10.4. SECAM adjustment
• Composite signal PAL
: 0.7Vp-p
± 0.02Vp-p (Pedestal to white level)
• 33K component signal (50 Hz)
: Y level
: 0.7Vp-p
± 0.02Vp-p (Pedestal to white level)
: PB, PR level
: 0.7Vp-p
± 0.02Vp-p
• ANALOG PC (RGB) signal
: RGB level
: 0.7Vp-p
± 0.02Vp-p
Adjustment point
Adjustment conditions
Adjustment procedure
1
Setting
[Signal]
PAL
Full field colour bar
composite signal
PAL
Full field colour bar
composite signal
[Terminal]
EXT1 SCART Video (PAL)
IN
EXT1 SCART Video (PAL)
IN
• Feed the PAL full field colour bar signal (75% colour saturation) to EXT1
SCART IN.
2
Auto adjustment
performance
performance
Adjustment process
[PAL ADJ] page 4/21
[PAL ADJ] page 4/21
Bring the cursor on [PAL ADJ] and press [OK].
[PAL ADJ OK] appears when finished.
[PAL ADJ OK] appears when finished.
Adjustment point
Adjustment conditions
Adjustment procedure
1
Setting
[Signal]
PAL sprit field colour Bar
RF signal UV
PAL sprit field colour Bar
RF signal UV
[Terminal]
TUNER
TUNER
• Feed the PAL Split Field colour bar signal (E-12ch) to TUNER.
• Make sure the PAL colour bar pattern has the sync level of 7:3 with the picture
• Make sure the PAL colour bar pattern has the sync level of 7:3 with the picture
level.
Signal level: 55 dB
µV ± 1dB (75Ω LOAD)
2
Auto adjustment
performance
performance
Adjustment process
[TUNER ADJ] page 3/21
[TUNER ADJ] page 3/21
Bring the cursor on [TUNER ADJ] and press [OK].
[TUNER ADJ OK] appears when finished.
[TUNER ADJ OK] appears when finished.
Adjustment point
Adjustment conditions
Adjustment procedure
1
Setting
[Signal]
SECAM
Full field colour Bar Signal
SECAM
Full field colour Bar Signal
[Terminal]
EXT1 SCART IN
EXT1 SCART IN
• Feed the SECAM full field colour bar signal (75% colour saturation) to EXT1
SCART IN.
2
Auto adjustment
performance
performance
Adjustment process
[SECAM ADJ] page 4/21
[SECAM ADJ] page 4/21
Bring the cursor on [SECAM ADJ] and press [OK].
[SECAM ADJ OK] appears when finished.
[SECAM ADJ OK] appears when finished.
[VIDEO input signal]
100% white
Black
[E-12CH]
χ
100% white
[VIDEO input signal]
100% white
Black
LC-60LE855E/K,60/70LE857E/RU,858E,70LE857K
5 – 18
10.5. ADC adjustment (Component 15K)
10.6. ADC adjustment (Component 33K)
10.7. PC signal adjustment (ANALOG D-Sub 15pin)
10.8. RGB (SCART) adjustment (RGB 15K)
Adjustment point
Adjustment conditions
Adjustment procedure
1
Setting
[Signal]
COMP15K, 50Hz
100% Full field colour bar
Signal
COMP15K, 50Hz
100% Full field colour bar
Signal
[Terminal]
EXT3 COMPONENT IN
EXT3 COMPONENT IN
• Feed the COMPONENT 15K 100% full field colour bar signal (100% colour
saturation) to EXT3 COMPONENT IN.
2
Auto adjustment
performance
performance
Adjustment process
[COMP15k ALL ADJ]
page 6/21
[COMP15k ALL ADJ]
page 6/21
Bring the cursor on [COMP15k ALL ADJ] and press [OK].
[COMP15K ALL ADJ OK] appears when finished.
[COMP15K ALL ADJ OK] appears when finished.
Adjustment point
Adjustment conditions
Adjustment procedure
1
Setting
[Signal]
COMP33K, 50Hz
100% Full field colour bar
Signal
COMP33K, 50Hz
100% Full field colour bar
Signal
[Terminal]
EXT3 COMPONENT IN
EXT3 COMPONENT IN
• Feed the COMPONENT 33K 100% full field colour bar signal (100% colour sat-
uration) to EXT3 COMPONENT IN.
2
Auto adjustment
performance
performance
Adjustment process
[HDTV ADJ] page 7/21
[HDTV ADJ] page 7/21
Bring the cursor on [HDTV ADJ] and press [OK].
[HDTV ADJ OK] appears when finished.
[HDTV ADJ OK] appears when finished.
Adjustment point
Adjustment conditions
Adjustment procedure
1
Setting
[Signal]
XGA, 60Hz
100% Full Field Colour Bar
Signal
XGA, 60Hz
100% Full Field Colour Bar
Signal
[Terminal]
PC IN
PC IN
• Feed the XGA 60Hz 100% full field colour bar signal (100% colour saturation)
to PC IN.
2
Auto adjustment
performance
performance
Adjustment process
[ANALOG PC ADJ] menu
page 8/21
[ANALOG PC ADJ] menu
page 8/21
Bring the cursor on [ANALOG PC ADJ] and press [OK].
[ANALOG PC ADJ OK] appears when finished.
[ANALOG PC ADJ OK] appears when finished.
Adjustment point
Adjustment conditions
Adjustment procedure
1
Setting
[Signal]
RGB 15K, 50Hz
100% Full field colour bar
signal
RGB 15K, 50Hz
100% Full field colour bar
signal
[Terminal]
EXT1 SCART RGB IN
EXT1 SCART RGB IN
• Feed the RGB 15k 50Hz 100% full field colour bar signal (100% colour satura-
tion) to EXT1 SCART IN.
2
Auto adjustment
performance
performance
Adjustment process
[SCART RGB ADJ] menu
page 9/21
[SCART RGB ADJ] menu
page 9/21
Bring the cursor on [SCART RGB ADJ] and press [OK].
[SCART RGB ADJ OK] appears when finished.
[SCART RGB ADJ OK] appears when finished.
100% white
Black
100% white
Black
100% white
Black
100% white
Black
LC-60LE855E/K,60/70LE857E/RU,858E,70LE857K
5 – 19
11. White balance adjustment
For white balance adjustment, adjust the offset values on pages 11/21.
[Condition of the unit for inspection] : Modulated light (+16)
AV MODE: DYNAMIC
Active Backlight: OFF
OPC: OFF
Asing Time: Min, 60 minute
[Input signal condition] : HDMI 1080i 15IRE (LO), 78IRE (HI)
[Adjustment reference device] : Minolta CA-210
[Adjustment procedure]
1) Display the current adjustment status at R/G/B_GAIN (HI). (Page 11/21 of process adjustment)
The signal of 78IRE is input.
2) Read the value of the luminance meter. x=0.272, y =0.277
3) Change R_GAIN (HI)/ B_GAIN (HI) (Adjustment offset value) on page 11/21 of process adjustment so that the values of the luminance meter
approach x=0.272 and y =0.277.
(Basically, G is not changed. If adjustment fails with R and B, change G. When G is lowered, the weaker of R or B must be fixed.)
4) Display the adjustment status of the current R/G/B_GAIN (LO).
The signal of 15IRE is input.
Change R_GAIN (LO)/ B_GAIN (LO) (adjustment offset value) on page 11/21 of process adjustment so that the values of the luminance meter
approach x =0.272 and y = 0.277.
approach x =0.272 and y = 0.277.
5) Both HI and LO are repeating the step from 1 to 4 until becoming an aim value.
[Adjustment reference standard value]
Adjustment spec
± 0.002 Inspection spec ± 0.004 (point LO)
Adjustment spec
± 0.001 Inspection spec ± 0.002 (point HI)
6) After completing adjustments, set EEP SAVE (Page 21/21) to ON in the process menu to save the white balance adjustment value.
12. Confirmation item
1. HDMI-CEC Inspection
After repairing the CEC function, check the operation about HDMI-CEC circuit.
2. CI card Inspection
After repairing the CI function, check that the DTV signal is received by inserting CAM.
And check the KEY certification by inserting CAM which is prepare for CI+.
3. LAN Inspection (NET)/test connectivity of SD card.
After repairing the LAN function, check the communication by connecting PC and LAN terminal.
And test connectivity of SD card.
4. 3D Check
5. Bluetooth communication Check / Bluetooth Emitter(Infrared light Output) Inspection.
LC-60LE855E/K,60/70LE857E/RU,858E,70LE857K
5 – 20
13. Initialization to factory settings
14. Upgrading the software
1. Turn on the AC power.
2. Insert the upgrading USB flash memory for upgrade into the service slot.
(After a while, an external input changes into USB automatically.)
3. Use the Menu button and cursor keys ( / / /
), Ch keys (
/
) of R/C or on the set to select HOME - TV Menu - Setup - Information - Soft-
ware update - USB update on OSD menu.
4. The message (Insert the USB memory device contains the software update file) shows up.
Push OK when if there is no problem.
CAUTION: When the factory settings have been made, all user setting data, including the channel settings, are initialized.
(The adjustments done in the adjustment process mode are not initialized.) Keep this in mind when initializing these settings.
Adjustment item
Adjustment conditions
Adjustment procedure
1
Factory settings
Ends by turning off the
MAIN POWER key.
(See to below caution)
MAIN POWER key.
(See to below caution)
[Factory setting with adjustment process mode]
• Enter the adjustment process mode.
• Move the cursor to [INDUSTRY INIT] on page 2/21.
• Use the R/C key to select a region from [EUROPE/RUSSIA/SWEDEN] and
• Enter the adjustment process mode.
• Move the cursor to [INDUSTRY INIT] on page 2/21.
• Use the R/C key to select a region from [EUROPE/RUSSIA/SWEDEN] and
press the [OK] key.
• “EXECUTING” display appears.
• After a while, “SUCCESS” display appears, the setting is completed.
• After a while, “SUCCESS” display appears, the setting is completed.
When succeeding: Background color (green)
When failing: Background color (red)
The following items are initialized in the factory setting.
1) User settings
2) Channel data (e.g. broadcast frequencies)
3) Maker option setting
4) Password data
When failing: Background color (red)
The following items are initialized in the factory setting.
1) User settings
2) Channel data (e.g. broadcast frequencies)
3) Maker option setting
4) Password data
After adjustments, exit the adjustment process mode.
To exit the adjustment process mode, unplug the AC power cord from the outlet to forcibly turn off the power.
When the power is turned off with the remote control, unplug the AC power cord and plug it back in (wait approximately 20 seconds before plugging
in the AC power cord).
After completing the NET connection., execute the NET initialization (Record of the server access).
To exit the adjustment process mode, unplug the AC power cord from the outlet to forcibly turn off the power.
When the power is turned off with the remote control, unplug the AC power cord and plug it back in (wait approximately 20 seconds before plugging
in the AC power cord).
After completing the NET connection., execute the NET initialization (Record of the server access).
Please execute the initialized in the factory setting again when you turn on the power supply after the initialized in the factory setting is set.
OK
ENTER:Enter
㨀㨂
[Information
Software update
USB update]
Insert the USB memory device containing
the software update file.
Click on the first or last page to see other LC-60LE855E (serv.man3) service manuals if exist.