Sharp LC-60LE831E (serv.man6) Service Manual ▷ View online
LC-52/60LE830E,RU/831E,S/833E
4 – 5
5. Removing of R/C, Operation Unit, ICON Unit, 3D IR Emitter Unit, Touch Sensor Unit.
1. Remove the 1 lock screw and detach the ICON Unit .
2. Detach the R/C, Operation Unit .
3. Detach the 3D IR Emitter Unit .
4. Detach the Touch Sensor Unit .
NOTE: The Touch Sensor unit reuse will be impossible, once it is stuck on front cabinet and exfoliates.
Front Cabinet Ass'y
[TK] [RA]
Touch Sensor Unit
[IR]
[RA]
[CI]
2
3
ICON
Unit
Unit
5
6
3D IR Emitter
Unit
Unit
4 R/C,
Operation
Unit
Unit
LC-52/60LE830E,RU/831E,S/833E
4 – 6
[2] REMOVING OF MAJOR PARTS (LC-60LE830E,RU/831E,S/833E)
1. Removing of Stand Unit and Rear Cabinet Ass’y.
1. Remove the 2 lock screws and detach the Stand Support Cover .
2. Remove the 4 lock screws and detach the Stand Unit .
3. Remove the 1 lock screw and detach the AC Cord Cover .
4. Disconnect AC Cord .
5. Remove the 4 Vesa Hole Covers , 7 lock screws and 18 lock screws and 3 lock screws
and detach the Rear Cabinet Ass’y .
4
Stand Unit
AC Cord
7
Rear Cabinet Ass'y
11
3
8
1
2
Stand Support Cover
5
6
9
AC Cord Cover
10
10
10
12
LC-52/60LE830E,RU/831E,S/833E
4 – 7
2. Removing of Speaker-L/R.
1. Remove the 2 lock screws and the 1 lock screw detach the Bottom Cover .
2. Remove the 14 lock screws and detach the Fixing Metal Angle .
3. Disconnect SP wire.
4. Detach the Speaker-L , Speaker-R .
[SP]
[SP]
5
Speaker-L
6
Speaker-R
3
1
4
Fixing Metal Angle
2 Bottom Cover
MAIN Unit
7
LC-52/60LE830E,RU/831E,S/833E
4 – 8
3. Removing of Connectors.
1. Disconnect the following connectors from the MAIN Unit. (SB, PD, LW, PL, RC, CI)
2. Disconnect the following connectors from the POWER SUPPLY Unit. (PD, L1, AS)
3. Disconnect the following connectors from the LCD Control Unit. (LW, PL)
MAIN Unit
POWER SUPPLY Unit
[PD]
[L1]
[PL]
[LW]
LCD Control Unit
MAIN Unit
[SB]
[PD]
[CI]
[RC]
[PL]
[LW]
[AS]