Sharp LC-46XD1E (serv.man5) Service Manual ▷ View online

LC-46/52XD1E-RU
5 – 9
8/13
[M GAMMA 1-3]
1
M GAMMA R 1
107
W/B adjustment, gradation 1R adjustment value
2
M GAMMA G 1
107
W/B adjustment, gradation 1G adjustment value
3
M GAMMA B 1
107
W/B adjustment, gradation 1B adjustment value
4
275
W/B adjustment, gradation 2R adjustment value
5
275
W/B adjustment, gradation 2G adjustment value
6
275
W/B adjustment, gradation 2B adjustment value
7
446
W/B adjustment, gradation 3R adjustment value
8
446
W/B adjustment, gradation 3G adjustment value
9
446
W/B adjustment, gradation 3B adjustment value
10
off/on
EEP writing of adjustment values
9/13
[M GAMMA 4-6]
1
M GAMMA R 4
660
W/B adjustment, gradation 4R adjustment value
2
M GAMMA G 4
660
W/B adjustment, gradation 4G adjustmnet value
3
M GAMMA B 4
660
W/B adjustment, gradation 4B adjustment value
4
835
W/B adjustment, gradation 5R adjustment value
5
835
W/B adjustment, gradation 5G adjustmnet value
6
835
W/B adjustment, gradation 5B adjustment value
7
960
W/B adjustment, gradation 6R adjustment value
8
960
W/B adjustment, gradation 6G adjustment value
9
960
W/B adjustment, gradation 6B adjustment value
10
off/on
EEP writing of adjustment values
10/13
[ETC]
1
EEP CLEAR
off/on
Clear of process
㵘adjustment EEP value
2
EEP CLEAR B
off/on
Clear of process adjustment value
㵘of B_mode.
3
STANDBYCAUSE RESET
off/on
Reset of STANDBY CAUSE
4
0/1
1
䋺* * * 0䋺* * *
5
OPTION
0
6
AUTO/EURO/UK
Destination setting
7
0
LAMP ERR RESET Initialization of L_ERR
8
0/1
LAMP ERR Inhibit L_ERR detection.
9
DTV CLR
off/on
Clear of DTV unit.
10
off/on
STOP of I2C DATA execution
11/13
[LCD]
1
OSC FREQ50
1279
INVERTER drive frequency setting
2
OSC FREQ60
1279
INVERTER drive frequency setting
3
PWM FREQ50
218
Frequency setting for INVERTER dimmer
4
PWM FREQ60
218
Frequency setting for INVERTER dimmer
5
VCOM ADJ
64
COMMON VIAS adjustment setting
6
QS
off/on
on/off of Quick Shoot Function
7
CSI
off/on
on/off of Change Shear Impulse
12/13
[LCD TESTPATTERN]
1
PATTERN
0
Display LCD test pattern.
13/13
Service B
1
[HDTV]
0-10
Contrast,Bright and Color Adjustment of HDTV
2
[SERVICE B2]
off/on
on/off of Auto Sw Adjustment
3
[BASE GAMMA 1]
0-1023
Base Gamma Adjustment 1
4
[BASE GAMMA 2]
0-1023
Base Gamma Adjustment 2
5
[BASE GAMMA 3]
0-1023
Base Gamma Adjustment 3
6
[BASE GAMMA 4]
0-1023
Base Gamma Adjustment 4
7
[BASE GAMMA 5]
0-1023
Base Gamma Adjustment 5
8
[BASE GAMMA 6]
0-1023
Base Gamma Adjustment 6
9
[QUICK SHOOT]
0-255
QS Sreshuhorld Level Adjustment
M GAMMA R 5
M GAMMA G 5
M GAMMA B 5
M GAMMA R 6
M GAMMA G 6
M GAMMA B 6
M GAMMA WRITE
AUTO INSTALLATION SW
COUNTRY
L ERR RESET
L ERR STOP
I2C-OFF
M GAMMA G 3
M GAMMA B 3
M GAMMA WRITE
M GAMMA R 2
M GAMMA G 2
M GAMMA B 2
M GAMMA R 3
LC-46/52XD1E-RU
5 – 10
6. Special features
* ERROR STANDBY CAUSE (Page 1/13)
The total time when the unit enters the standby due to operational error and cause of error are recorded on EEPROM as much as possible.
The values can be used to locate the fault for repair.
* EEP CLEAR (Page10/13)
Clear of process adjustment EEP value.
7. Inch Setting
8. Video signal adjustment procedure  * The adjustment process mode menu is listed in Section 5.
1. Signal check
Signal generator level adjustment check (Adjustment to the specified level)
• Composite signal PAL : 0.7Vp-p 
± 0.02Vp-p (Pedestal to white level)
• 15K component signal : Y level 0.7Vp-p 
± 0.02Vp-p (Pedestal to white level)
 (50 Hz)                              PB, PR level 0.7Vp-p 
± 0.02Vp-p
2. Entering the adjustment process mode
Enter the adjustment process mode according to Section 3. 
3. RF AGC adjustment 1
1 Factory settings
䊶 Enter the adjustment process mode.
䊶 Move the cursor to [INCH SETTING] on page 2/13.
䊶 Use the R/C 㵘㵘key to select a inch size from
[46/52] and press the [OK]
㵘key.
䊶 “EXECUTING” display appears .
䊶 After a while,"OK" display appears, the setting is completed.
Adjustment point Adjustment Conditions
Adjustment
㵘procedure
ends by turning off
the MAIN POWER
1
Setting
[Signal]
䊶 Feed the PAL Sprit Field colour bar signal (E-12ch) to TUNER.
PAL
㵘 Signal level: 65 dB V㵘±1dB 㵘㵘(75
LOAD)
Sprit Field Colour Bar
RF signal UV
[E-12CH]
[Terminal]
TUNER
㸡100% white
2
Auto adjustment
Adjustment process
Bring the cursor on [ RF AGC BG ADJ] and press [OK]
performance
[PAL+TUNERMAIN] menu
[RF AGC BG ADJ
㵘OK] appears when finished.
Adjustment Conditions
Adjustment
㵘procedure
Adjustment point
LC-46/52XD1E-RU
5 – 11
4. PAL signal & tuner adjustment
5. ADC adjustment (Component 15K)
1 Setting
[Signal]
䊶Feed the PAL full field colour bar signal (75% colour saturation) to
PAL
㵘EXT3 VIDEO IN.
Full Field Color Bar
䊶Feed the RF signal (PAL colour bar) to TUNER.
Composite or RF signal
䊶Make sure㵘the PAL colour bar pattern (E-12) has㩷the sync level of
㵘7.3 with the picture level.
[Terminal]
EXT3 VIDEO IN
TUNER
㸡100% white
2
Auto adjustment
Adjustment process
Bring the cursor on [
PAL+TUNER ADJ]
and press [OK].
performance
[PAL+TUNERMAIN] menu
[
PAL+TUNER ADJ
OK] appears when finished.
䈀VIDEO IN SIGNAL䈁
㸡100% white
Adjustment point Adjustment conditions
䈀E-12CH䈁
Adjustment procedure
1 Setting
[Signal]
䊶Feed the COMPONENT 15K 100% full field colour bar signal (100%
COMP15K, 50Hz
㵘colour saturation) to EXT4 COMPONENT IN.
100% Full Field Colour Bar
[Terminal]
EXT4 COMPONENT IN
2
Auto adjustment
Adjustment process
Bring the cursor on [COMP ALL ADJ] and press [OK].
performance
[COMP] menu
[COMP ALL ADJ OK] appears when finished.
100% white
Black
Adjustment point Adjustment conditions
Adjustment procedure
LC-46/52XD1E-RU
5 – 12
9. White Balance Adjustment
Adjustment gradation values (IN) appear on page 7/13 of process adjustment, and adjustment initial values(offset value) appear on pages 8/13 and 9/
13. 
For white balance adjustment, adjust the offset values on pages 8/13 and 9/13.
[Condition of the unit for inspection]  
 Modulated light: MAX (+8)
[Adjustment reference device]  
Minolta CA-210
[Adjustment]
Check that the values on page 7/13 of process adjustment are set as below. If not, change them accordingly.
1. Display the current adjustment status at point 6. (Page 8/13 of process adjustment)
The display for checking the adjustment status is toggled by pressing the “6” button on the remote control.
(Normal OSD display 
→ “6” → display for check (OSD disappears) → “6” →normal OSD display → . . . )
2. Read the value of the luminance meter.  x=0.272 , y =0.277
3. Change MGAMMA R6/MGAMMA  B6 (Adjustment offset value) on page 9/13 of process adjustment so that the values of the luminance meter
approach x=0.272 and y =0.277.
(Basically, G is not changed. If adjustment fails with R and B, change G. When G is lowered, the weaker of R and B must be fixed.)
4. Display the adjustment status of the current point 5. (Each time the “5” button on the remote control is pressed, the adjustment status check dis-
play is toggled.)
(Normal OSD display 
→ “5” → Check display (OSD disappears) → “5” →Normal OSD display → . . . )
Change M GAMMA R5/M GAMMA B5 (adjustment offset value) on page 9/13 of process adjustment so that the values of the luminance meter
approach x = 0.272 and y = 0.277.
5. Repeat step 4) for points 4, 3, 2,  and 1.
[Adjustment reference standard value]
Adjustment spec  
± 0.004    Inspection spec  ± 0.006  (point 1)
Adjustment spec  
± 0.002    Inspection spec  ± 0.004  (Excluding the above-mentioned)
MGAMMA POS 1
4
MGAMMA POS 2
9
MGAMMA POS 3
14
MGAMMA POS 4
20
MGAMMA POS 5
25
MGAMMA POS 6
29
Page of 16