LC-46X8E/S/RU
3 – 8
6. Special features
1. NORMAL STANDBY CAUSE (Page 1/33)
Display of a cause (code) of the last standby.
The cause of the last standby is recorded in EEPROM whenever possible.
Checking this code will be useful in finding a problem when you repair the troubled set.
2. EEP SAVE (Page 33/33)
Storage of EEP adjustment value
3. EEP RECOVER (Page 33/33)
Retrieval of EEP adjustment value from storage area.
7. Lamp error detection
1. Function
This LCD color TV set incorporates a lamp error detection feature that automatically turns off the power for safety under abnormal lamp or lamp
circuit conditions. If by any chance anything is wrong with the lamp or lamp circuit or if the lamp error detection feature is activated for some rea-
son, the following will result.
1) The power is interrupted in about 6 seconds after it is turned on.
(The power LED on the front of the TV set turns red from green and keeps blinking in red: ON for 250 ms and OFF for 1 sec.).
2) If the above phenomenon 1) occurs 5 times consecutively, it becomes impossible to turn on the power. (The power LED remained red).
2. Measures
1) Checking with lamp error detection OFF
Enter the adjustment process mode, referring to 2. Entering and exiting the adjustment process mode.
If there is a problem with the lamp or lamp circuit, the lamp will go out. (The power LED is green.)
Then, you can check the operation to see if the lamp and lamp circuit are in trouble.
2) Resetting the lamp error count
After the lamp and lamp circuit are found out of trouble, reset the lamp error count. If a lamp error is detected five consecutive times, the power
cannot be turned on. Using the cursor (UP/DOWN) key, move to the cursor to [LAMP ERROR RESET], Line 8 on adjustment process mode
service page 2/33. With the cursor (LEFT/RIGHT) keys, select the [LAMP ERROR RESET] value. Finally press the cursor (OK) keys to reset
the value to “0”. 
Table of contents of adjustment process mode Page 2/33
[INIT]
INDUSTRY INIT
Enter
INDUSTRY INIT(-Hotel)
OFF
HOTEL MODE
OFF
Center Acutime
RESET
OFF
Backlight Acutime
RESET
OFF
LAMP ERROR RESET
OFF
ADJ PARAM SET
Enter
VIC XPOS
0
VIC YPOS
0
VIC SIGNAL TYPE
MAIN
VIC READ
OFF
Resetting to "0"
LC-46X8E/S/RU
3 – 9
8. Public Mode (Hotel Mode)
1. Starting the Public Mode
• There are two following ways to display the PUBLIC Mode setting screen.
1) On the process adjustment mode screen (2/33), set the “HOTEL MODE” Flag to ON.
Turn off the power, and turn it on again, pressing the 
 and 
 keys of the main unit at the same time.
2) Enter the Pass Word, and start the unit.
a) Turn on the power, pressing the 
 and 
 keys of the main unit at the same time.
b) Display the Pass Word input screen.
Operation procedure
• The initial input position is the digit at the left end.
• For the numeric keys 
 to 
 of R/C, key input is accepted. Input of the other keys is prohibited.
• Change “-” to “*” by inputting the numeric key at the input position, and shift the input position rightward one digit.
• When three digits are completely input, the Pass Word is judged.
c) Check the Pass Word by inputting three digits.
If the Pass Word is 
, it shifts to the PUBLIC Mode setting screen.
In another case, the screen is erased, and it operates in the ordinary mode.
2. Exiting the Public Mode screen
• There are two following ways to exit the Public Mode setting screen.
1) Turn off the power.
2) Select “EXECUTE” in the PUBLIC_Mode to execute it.
Activate the restart under the set content. Here, the START input SOURCE setting is excluded since this item is referred to only when the
power is turned on.
3. Set value of the Public Mode
• Each set value in the PUBLIC Mode is initialized when the factory setting is applied.
(The setting of the PUBLIC MODE Flag in the process adjustment mode screen is not changed.)
CHANNEL UP
Volume UP
INPUT
Volume UP
0
9
0
2
7
LC-46X8E/S/RU
3 – 10
4. Basic operation in the Public Mode
5. Operation after “RESET”
Select “RESET” in the PUBLIC Mode, and it operates as follows when it is executed (refer to the basic operation).
• The set contents in the PUBLIC mode are initialized.
• It does not exit the PUBLIC mode.
• PUBLIC MODE Flag does not change. (It is not set to OFF.)
Volume (+/-) or Cursor (
/
)
Change or execution of the set value.
Channel (
/
) or Cursor (
/
)
Movement to the selected item.
Decision (ok)
Execution (Used by the items “Execution” and “RESET”.) 
PUBLIC Mode R/C
Ordinary operation mode: It enters the PUBLIC Mode.
PUBLIC MODE Flag is set to “ON”.
PUBLIC Mode: It exits the PUBLIC Mode.
PUBLIC MODE Flag does not change.
Any set item in PUBLIC Mode is not initialized.
Public Mode
POWER ON FIXED
[VARIABLE]
SHUT DOWN MODE
[NORMAL]
MAXIMUM VOLUME
[60]
VOLUME FIXED
[VARIABLE]
VOLUME FIXED LEVEL
[20]
RC BUTTON
[RESPOND]
PANEL BUTTON
[RESPOND]
MENU BUTTON
[RESPOND]
AV POSITION FIXED
[VARIABLE]
ON SCREEN DISPLAY
[YES]
INPUT MODE START
[NORMAL]
INPUT MODE FIXED
[VARIABLE]
LOUD SPEAKER
[ON]
RC PATH THROUGH
[OFF]
232C POWON
[DISABLE]
HOTELMODE
[ON]
RESET
EXECUTE
LC-46X8E/S/RU
3 – 11
6. Setting items (* Item names and selective items are expressed in English.)
1) Power ON Fixed (POWER ON FIXED)
If the power button is pressed in the ordinary mode when set to “FIXED”, the caution is displayed for 5 seconds.
       When power button on the main unit is pressed                             When power button on R/C is pressed
* The OSD display is an example.
If another ODS is previously displayed, the status is reset (MENU or similar).
2) Volume Maximum Level [MAXIMUM VOLUME]
3) Volume Fixed [VOLUME FIXED]
4) Volume Fixed Level [VOLUME FIXED LEVEL]
Selection
“VARIABLE” or “FIXED” is selectable. (Loop is provided.)
Default
“VARIABLE”
Function
• When "FIXED" is set, “Power ON/Standby Key” of the main unit and R/C is disabled.
Keys disabled when not 
set to Default
• OFF_TIMER (SLEEP)
Remarks
The function does not work for any other standby factors (see below).
• No operation OFF
• No signal OFF (including the power management)
Selection
0~60 (Loop is not provided.)
Default
60
Function
• Even if VOL is adjusted to a value higher than the adjusted one, it is not set to that value. (Only the speakers of 
the main unit)
Exception
Remarks
• When it is set to 59 or less, the number is displayed and the volume bar is not displayed during operation in the 
ordinary mode.
• VOLUME can be abbreviated to VOL.
Selection
“VARIABLE” or “FIXED” is selectable. (Loop is provided.)
Default
“VARIABLE”
Function
It is selectable whether or not the volume is fixed to the value adjusted in the volume fixed level mode. (Only the 
speakers of the main unit)
Exception
• In the adjustment process, the volume can be set as desired regardless of this setting.
Keys disabled when not 
set to Default
• Volume high/low (VOL+/-) (Both R/C and main unit)
• Mute (MUTE)
Remarks
• Volume Fixed is prior to Volume Maximum Level.
• Even if the above disabled keys are operated, the volume is not displayed.
• VOLUME can be abbreviated to VOL.
Selection
0~60 (Loop is not provided.)
Default
Currently set volume
Function
The volume is fixed to the adjusted value. (Only the speakers of the main unit)
Exception
• In the adjustment process, the volume can be set as desired regardless of this setting.
Keys disabled when not 
set to Default
Remarks
• When Volume Fixed is set to “VARIABLE”, the setting is inhibited to change.
• VOLUME can be abbreviated to VOL.
No Power off by power button.
No Power off by remote control.