LC-46DH65E/S, LC-46DH66E
3 – 4
8/16
1
ANALOG PC ADJ
Enter
DVI ANALOG video level adjustment
2
R OFFSET
64
R CUTOFF adjustment value
3
G OFFSET
64
G CUTOFF adjustment value
4
B OFFSET
66
B CUTOFF adjustment value
5
R GAIN
193
R DRIVE adjustment value
6
G GAIN
189
G DRIVE adjustment value
7
B GAIN
194
B DRIVE adjustment value
9/16
1
SCART RGB ADJ
Enter
SCART RGB level adjustment
2
SCART R CUTOFF
65
SCART R CUTOFF adjustment value
3
SCART G CUTOFF
60
SCART G CUTOFF adjustment value
4
SCART B CUTOFF
64
SCART B CUTOFF adjustment value
5
SCART R GAIN
200
SCART R GAIN adjustment value
6
SCART G GAIN
195
SCART G GAIN adjustment value
7
SCART B GAIN
201
SCART B GAIN adjustment value
10/16
1
VCOM ADJ
69
2
LCD LUMA ADJ
Enter
3
LCD LUMA UP
26
4
LCD LUMA DOWN
13
11/16
1
DDRA TEST1
Enter
2
DDRA TEST2
Enter
3
DDRB TEST1
Enter
4
DDRB TEST2
Enter
5
DDRB TEST3
Enter
6
FRC ON/OFF
Enter
7
SOUSAM DDR BIST
Enter
8
SOUSAS DDR BIST
Enter
12/16
1
R GAIN(LO)
0
2
G GAIN(LO)
0
3
B GAIN(LO)
0
4
R GAIN(HI)
0
5
G GAIN(HI)
0
6
B GAIN(HI)
0
13/16
1
MONITOR TIME OUT
ON
2
MONITOR MAX TEMP
30
3
MONITOR EEP READ/WRITE
WRITE
4
MONITOR EEP ADR
0x 0
5
MONITOR EEP DATA
0x 0
14/16
1
LCD TEST PATTERN
OFF
Pattern with built-in LCD controller display
15/16
1
READ/WRITE
READ
2
SLAVE ADDRESS
SLAVE0
3
REGISTER ADDRESS
0x 0
0x 0
4
WRITE  DATA
0x  0
0x 0
5
READ DATA
0x 0
0x 0
16/16
1
EEP SAVE
OFF
Writing setting values to EEPROM.
2
EEP RECOVER
OFF
Reading setting values from EEPROM.
3
MONITOR ERROR CAUSE RESET
OFF
4
STANDBY CAUSE RESET
OFF
Reset stand by cause.
5
MODEL NAME
DH65
6
PANEL SIZE
46
7
PRODUCT EEP ADR
0x 0
8
PRODUCT EEP DATA
0x 0
Page
Line
Item
Description
Remarks (adjustment detail, etc.)
LC-46DH65E/S, LC-46DH66E
3 – 5
6. Special features
1. NORMAL STANDBY CAUSE (Page 1/16)
Display of a cause (code) of the last standby.
The cause of the last standby is recorded in EEPROM whenever possible.
Checking this code will be useful in finding a problem when you repair the troubled set.
2. EEP SAVE (Page 16/16)
Storage of EEP adjustment value
3. EEP RECOVER (Page 16/16)
Retrieval of EEP adjustment value from storage area.
7. Lamp error detection
1. Function
This LCD color TV set incorporates a lamp error detection feature that automatically turns off the power for safety under abnormal lamp or lamp
circuit conditions. If by any chance anything is wrong with the lamp or lamp circuit or if the lamp error detection feature is activated for some rea-
son, the following will result.
1) The power is interrupted in about 6 seconds after it is turned on.
(The power LED on the front of the TV set turns red from green and keeps blinking in red: ON for 300ms and OFF for 1500ms.).
2) If the above phenomenon 1) occurs 5 times consecutively, it becomes impossible to turn on the power. (The power LED remained red).
2. Measures
1) Checking with lamp error detection OFF
Enter the adjustment process mode, referring to 2. Entering and exiting the adjustment process mode.
If there is a problem with the lamp or lamp circuit, the lamp will go out. (The power LED is green.)
Then, you can check the operation to see if the lamp and lamp circuit are in trouble.
2) Resetting the lamp error count
After the lamp and lamp circuit are found out of trouble, reset the lamp error count. If a lamp error is detected five consecutive times, the power
cannot be turned on. Using the cursor (
/
) key, move to the cursor to [LAMP ERROR RESET], Line 8 on adjustment process mode ser-
vice page 2/16. With the cursor (</>) keys, select the [LAMP ERROR RESET] value. Finally press the cursor (OK) eys to reset the value to “0”.
Table of contents of adjustment process mode Page 2/16
INDUSTRY INIT
Enter
INDUSTRY INIT(-Hotel)
OFF
HOTEL MODE
OFF
5H0M
Center Acutime
RESET
OFF
Backlight Acutime
RESET
OFF
LAMP ERROR RESET
OFF
ADJ PARAM SET
Enter
VIC XPOS
0
VIC YPOS
0
VIC SIGNAL TYPE
MAIN
VIC READ
OFF
Resetting to "0"
LC-46DH65E/S, LC-46DH66E
3 – 6
8. Public Mode (Hotel Mode)
1. Starting the Public Mode
• There are two following ways to display the PUBLIC Mode setting screen.
1) On the process adjustment mode screen (2/16), set the “HOTEL MODE” Flag to ON.
Turn off the power, and turn it on again, pressing the 
 and 
 keys of the main unit at the same time.
2) Enter the Pass Word, and start the unit.
a) Turn on the power, pressing the 
 and 
 keys of the main unit at the same time.
b) Display the Pass Word input screen.
Operation procedure
• The initial input position is the digit at the left end.
• For the numeric keys 
 to 
 of R/C, key input is accepted. Input of the other keys is prohibited.
• Change “–” to “*” by inputting the numeric key at the input position, and shift the input position rightward one digit.
• When three digits are completely input, the Pass Word is judged.
c) Check the Pass Word by inputting three digits.
If the Pass Word is 
, it shifts to the PUBLIC Mode setting screen.
In another case, the screen is erased, and it operates in the ordinary mode.
2. Exiting the Public Mode screen
• There are two following ways to exit the Public Mode setting screen.
1) Turn off the power.
2) Select “Execution” in the PUBLIC_Mode to execute it.
Activate the restart under the set content. Here, the START input SOURCE setting is excluded since this item is referred to only when the
power is turned on.
3. Set value of the Public Mode
• When the shipment setting is done, a set each value in Public Mode is initialized.
(PUBLIC MODE in the process mode Setting of a flag is also initialized)
• Separately, the shipment beginnings when all except for each set value in Public Mode is initialized are provided for a process mode. (INDUS-
TRY INIT (-HOTEL) )
• Only when turning on the HOTELE MODE item, each setting is effective.
• After it decides it with EXECUTE, it AC OFF/ON it to reflect a set value.
CHANNEL UP
Volume UP
INPUT
Volume UP
Public Mode
Public Mode
Public Mode
0
9
0
2
7
LC-46DH65E/S, LC-46DH66E
3 – 7
4. Basic operation in the Public Mode
5. Operation after “RESET”
Select “RESET” in the PUBLIC Mode, and it operates as follows when it is executed (refer to the basic operation).
• The set contents in the PUBLIC mode are initialized.
• It does not exit the PUBLIC mode.
• If “EXCUTE” is not executed, the content that does RESET is not reflected.
Volume 
/
 or Cursor 
</>
Change or execution of the set value.
Channel 
/
 or Cursor 
/
Movement to the selected item.
Decision (ok)
Execution (Used by the items “Execution” and “RESET”.)
PUBLIC Mode R/C
Ordinary operation mode: It enters the PUBLIC Mode.
PUBLIC MODE Flag is set to “ON”.
PUBLIC Mode: It exits the PUBLIC Mode.
PUBLIC MODE Flag does not change.
Any set item in PUBLIC Mode is not initialized.
Public Mode
POWER ON FIXED
[VARIABLE]
SHUT DOWN MODE
[NORMAL]
MAXIMUM VOLUME
[60]
VOLUME FIXED
[VARIABLE]
VOLUME FIXED LEVEL
[20]
RC BUTTON
[RESPOND]
PANEL BUTTON
[RESPOND]
MENU BUTTON
[RESPOND]
AV POSITION FIXED
[VARIABLE]
ON SCREEN DISPLAY
[YES]
INPUT MODE START
[NORMAL]
INPUT MODE FIXED
[VARIABLE]
LOUD SPEAKER
[ON]
RC PATH THROUGH
[OFF]
232C POWON
[DISABLE]
HOTELMODE
[ON]
RESET
EXECUTE
Page of 16
Display

Sharp LC-46DH66 (serv.man4) Service Manual ▷ Download

  • DOWNLOAD Sharp LC-46DH66 (serv.man4) Service Manual ↓ Size: 644.2 KB | Pages: 16 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp LC-46DH66 (serv.man4) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp LC-46DH66 (serv.man4) LCD. Information contained in Sharp LC-46DH66 (serv.man4) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.