DOWNLOAD Sharp LC-40LU700E (serv.man2) Service Manual ↓ Size: 993.72 KB | Pages: 29 in PDF or view online for FREE

Model
LC-40LU700E (serv.man2)
Pages
29
Size
993.72 KB
Type
PDF
Document
Handy Guide
Brand
Device
TV / LCD / Version 1.1
File
lc-40lu700e-sm2.pdf
Date

Sharp LC-40LU700E (serv.man2) Handy Guide ▷ View online

 
 
 
 
 
Pin Assignments 
 
 
 
Version 1.1 
Issue 07/2010
 
 
 
10
 
 
SHARP ELECTRONICS (UK) LTD 
CE TECHNICAL SUPPORT 
TECHNICAL SERVICES GROUP 
 
 
RS-232C Terminal: 9-pin D-sub male connector of the DIN-D-sub RS-232C adapter 
 
Pin No.  
Signal  
Name  
I/O  
Reference 
1  
CD  
 
 
Not connected 
2  
RD  
Receive Data  
Input 
Connected to internal circuit 
3  
SD  
Send Data  
Output 
Connected to internal circuit 
4  
ER  
 
 
Not connected 
5  
SG  
Signal Ground  
 
Connected to internal circuit 
6  
 
 
 
Not connected 
7  
 
 
 
Not connected 
8  
 
 
 
Not connected 
9  
CI  
 
 
Not connected
 
 
RS-232C Cable recommended connection: 
9-pin D-sub female connector 
 
 
Note 
 
Depending on the controlling device used, it may be necessary to connect Pin 4 and Pin 6 
on the controlling device (e.g. PC).
 
 
 
 
 
 
 
Maintenance Procedure 
 
 
 
Version 1.1 
Issue 07/2010
 
 
 
11
 
 
SHARP ELECTRONICS (UK) LTD 
CE TECHNICAL SUPPORT 
TECHNICAL SERVICES GROUP 
 
 
Cleaning the LCD  
 
Ensure you unplug the power cord before cleaning the LCD.  
 
The cabinet as well as the operation panel is made of plastic. Avoid 
using benzene or thinner, as these can damage the finish on the 
cabinet.  
 
Do not use volatile agents such as insecticides on the LCD. Do not 
attach rubber or plastic items on the LCD for long periods of time. 
The effects of some of the agents in the plastic may cause damage 
to the quality or finish of the LCD.  
 
Wipe off dirt gently with a soft flannel cloth.  
 
When the dirt is hard to remove, soak a cloth in a neutral detergent 
diluted with water, wring the cloth well and then wipe the LCD.  
Strong cleaning detergents may discolour, warp or damage the coating on the LCD. 
Ensure you test on a small, inconspicuous area on the LCD before using.  
 
 
Cleaning the exhaust and intake vents  
 
Use a vacuum cleaner to clean dust from the exhaust vent and the intake vent.
 
 
 
 
 
Firmware Upgrade Procedure 
 
 
 
Version 1.1 
Issue 07/2010
 
 
 
12
 
 
SHARP ELECTRONICS (UK) LTD 
CE TECHNICAL SUPPORT 
TECHNICAL SERVICES GROUP 
 
 
Firmware Upgrade Procedure 
 
Part Number 
Description 
Price Rank 
Commercially Available 
USB Pen Drive 32MB - 1GB 
N/A 
 
1.  Turn off the AC power (Unplug the AC power cord). 
2.  Insert the upgrading USB flash memory for upgrade into the service slot. 
3.  While holding down the power button, plug in the AC power cord of the main unit to 
turn on the power. 
4.  Upgrade begins automatically. 
After the set starts, the upgrade screen like the figure below is displayed.
 
 
 
 
5.  If any of the procedures fails, the following upgrade failure screen shows up. For the 
failing procedure, the “NG” marking turns red. 
NOTE: In such case, try to upgrade the software again. If it still fails, the 
hardware may be in trouble.
 
 
 
 
 
 
 
Firmware Upgrade Procedure 
 
 
 
Version 1.1 
Issue 07/2010
 
 
 
13
 
 
SHARP ELECTRONICS (UK) LTD 
CE TECHNICAL SUPPORT 
TECHNICAL SERVICES GROUP 
 
 
6.  When all the procedures are complete, the following upgrade success screen shows 
up. The new software version can be confirmed on screen. 
The version number appears when each item has been successfully upgraded. Finally 
the main version number appears on screen. 
 
 
 
7.  Turn off the AC power (Unplug the AC power cord). Take out the upgrading USB flash 
memory. 
It waits for about 20 seconds until the AC power supply is turned off. 
8.  Now the software has been upgraded. 
NOTE: Then get the set started and call the process adjustment screen 1/17 to 
check the main software version.
 
CAUTION: 
1) Do not take out and put in the USB flash memory during formatting. 
2) It takes about one minute to the rewriting completion. 
Please confirm the upgrade status on the screen becomes 100%. 
3) The AC power supply of the set is waited for about 20 seconds until off (The 
AC outlet is pulled out) after the upgrade is completed.
Page of 29