Sharp LC-39LD145K (serv.man6) Service Manual / Technical Bulletin ▷ View online
LCD 2014 07 04
Date of Issue:
8
th
July 2014
Classification:
White
LCD TELEVISION TECHNICAL BULLETIN
Page 1 of 2
Sharp Electronics (UK) Limited
Reference
– RG08072014-3
Revision - 1
White
– Carry out as required
Yellow
– Carry out as required and whenever the unit comes in for service
Red
– Carry out on all units
MODELS
LC32LD145K
LC32LD145K(B)
LC39LD145K
LC39LD145K(B)
REASON
Unit will not start and remains in a dead condition.
If you try to update the normal firmware, the firmware update proceeds (Flashing LED)
but the Television never turns on.
If you try to update the normal firmware, the firmware update proceeds (Flashing LED)
but the Television never turns on.
ACTION
Once you have diagnosed a fault on the main board by trying to update the firmware,
there is a 2 step recovery process:
Step 1
there is a 2 step recovery process:
Step 1
o Download the recovery firmware (Including the HDCP Keys) from the Technical
Website.
o Follow the firmware upgrade procedure outline in the upgrade procedure
Technical Bulletin.
Step 2
LCD 2014 07 04
Date of Issue:
8
th
July 2014
Classification:
White
LCD TELEVISION TECHNICAL BULLETIN
Page 2 of 2
Sharp Electronics (UK) Limited
Reference
– RG08072014-3
Revision - 1
White
– Carry out as required
Yellow
– Carry out as required and whenever the unit comes in for service
Red
– Carry out on all units
If you are unable to recover the firmware, you need to replace the flash memory U10
and U12. Refer to the model service manual for the correct part number.
When ordering the memory, ensure you provide parts centre with the 2 x serial
number located on the rating plate of the affected unit. If you fail to provide both serial
numbers, you will receive the incorrect part.
and U12. Refer to the model service manual for the correct part number.
When ordering the memory, ensure you provide parts centre with the 2 x serial
number located on the rating plate of the affected unit. If you fail to provide both serial
numbers, you will receive the incorrect part.
Display