4 – 21
<During external connection> No picture on the monitor (4)
SCART2:
No picture from EXT3 appears on EXT2- connected monitor.
No picture from EXT3 appears on EXT2- connected monitor.
TERMINAL UNIT:
Is CVBS signal input from pin (51) of IC506 to pin (19) of
SCART2 (SC503)?
Is CVBS signal input from pin (51) of IC506 to pin (19) of
SCART2 (SC503)?
YES
Check the setting of an external input device that connects of
SC503.
SC503.
NO
Is CVBS signal input from pin (5) of the connector P501 to pin (3)
of IC506 (VIDEO SELECTOR)?
of IC506 (VIDEO SELECTOR)?
YES
Check the IC506 and its peripheral circuits.
MINI AV UNIT:
NO
Is CVBS signal input from pin (6) of the input terminal J901 to pin
(5) of the connector (P501)?
(5) of the connector (P501)?
YES
Check the connector (P501/P901)
NO
Is V3_PLUG signal of the CVBS signal detection function from
pin (7) of the input terminal J901 normal?
pin (7) of the input terminal J901 normal?
YES
Check the setting of an external input device that connects of
J901.
J901.
NO
Check between V3_PLUG_LINE J901 and pin (2) of IC506 in the
TERMINAL UNIT. (Connector P901/P501, etc.)
TERMINAL UNIT. (Connector P901/P501, etc.)
LED flashing atterns for error notification
1) Power LED
Error type
Power LED operation (1 cycle)
Description
Lamp failure
H: On
ERR_PNL(IC2002_43pin): Abnormal L. Confirmed after 5 consec-
utive detections at 1 second intervals.
(Detected only when the backlight is light is on).
utive detections at 1 second intervals.
(Detected only when the backlight is light is on).
Flashes once: Fast
L: Off
Note that after five detection counts, the lamp cannot be activated
except in the monitoring process.
(For the first time doesn't make an error only by inverter reset
OFF)
Accumulated counts are cleared to 0 when the corresponding set-
ting in the process adjustment(2/33) is made or when the power is
turned on with [CH_DOWN] and [VOL_UP] on the unit down or
after continuous illumination for 3 minutes.
except in the monitoring process.
(For the first time doesn't make an error only by inverter reset
OFF)
Accumulated counts are cleared to 0 when the corresponding set-
ting in the process adjustment(2/33) is made or when the power is
turned on with [CH_DOWN] and [VOL_UP] on the unit down or
after continuous illumination for 3 minutes.
Power failure
H: On
Refer to "Power failure details".
Flashes twice
L: Off
Communication fail-
ure with main CPU
ure with main CPU
H: On
Refer to "Communication failure details".
Communication line failure or main CPU(IC8101) communication
failure.
Communication line failure or main CPU(IC8101) communication
failure.
Flashes 3 times
L: Off
→Check main CPU (IC8101).
Monitor temp. failure H: On
If the panel temperature is 60
°C or more for 15 seconds or more in
a row, CAUTION appears.
If the panel temperature is 60
If the panel temperature is 60
°C or more for 15 seconds or more in
a row, error standby is activated.
Flashes 5 times
L: Off
(MONITOR MAX TEMP of process adjustment(29/33): Change of
temperature failure AD value): Thermistor
temperature failure AD value): Thermistor
250ms
1sec
LC-32XL8E/S/RU, LC-37XL8E/S/RU
4 – 22
2) Power failure details(Power LED flashes twice and OPC LED flashes)
Error type
OPC LED operation (1 cycle)
Description
PS_ON
H: On
AC_DET(IC2002_16pin): Abnormal (L). Main converter 12V is not
applied.
applied.
12V failure
If error is detected during operation, the power is turned on again
by interrupt handling.
by interrupt handling.
Flashes once
L: Off
PS_ON
H: On
DET_10V(IC2002_57pin): Abnormal (L). Main power UR13V is
not applied.
not applied.
10V failure
If error is detected during start-up or operation, the power is
turned on again by polling.
turned on again by polling.
Flashes 3 times
L: Off
D_POW
H: On
DET_D3V3(IC2002_59pin): Abnormal (L). D3.3V is not applied.
Digital 3.3V failure
If error is detected during start-up or operation, the power is
turned on again by polling.
turned on again by polling.
Flashes 4 times
L: Off
PANEL_POW
H: On
DET_PNL12V(IC2002_58pin): Abnormal (L). Panel power is not
applied.
applied.
Panel 12V failure
If error is detected during start-up or operation, the power is
turned on again by polling.
turned on again by polling.
Flashes 5 times
L: Off
Main failure
H: On
Main microprocessor detection error
The details are displayed on page 1 of process adjustment for the
main microprocessor (IC8101).
The details are displayed on page 1 of process adjustment for the
main microprocessor (IC8101).
Flashes 7 times
L: Off
3) Communication failure details(Power LED flashes 3 times and OPC LED flashes)
Error type
OPC LED operation (1 cycle)
Description
Initial communica-
tion reception failure
tion reception failure
H: On
Initial communication from the main CPU (IC8101) is not received.
→Communication line failure or main CPU (IC8101) start-up fail-
ure
→Communication line failure or main CPU (IC8101) start-up fail-
ure
Flashes once
L: Off
Start-up confirma-
tion reception failure
tion reception failure
H: On
Start-up reason confirmation from the main CP(IC8101) is not
received.
→Main CPU (IC8101) start-up failure or monitor microprocessor
(IC2002) reception failure
received.
→Main CPU (IC8101) start-up failure or monitor microprocessor
(IC2002) reception failure
Flashes twice
L: Off
Regular communi-
cation failure
cation failure
H: On
Regular communication that is performed at 1 second intervals in
the normal operation is interrupted.
→Main CPU (IC8101) operation failure or monitor microprocessor
(IC2002) reception failure
the normal operation is interrupted.
→Main CPU (IC8101) operation failure or monitor microprocessor
(IC2002) reception failure
Flashes 3 times
L: Off
Restart failure
H: On
When restarted by a software with the standby off/on, restart com-
pletion notification is not received.
→Main CPU (IC8101)restart failure to monitor microprocessor
(IC2002) reception failure
pletion notification is not received.
→Main CPU (IC8101)restart failure to monitor microprocessor
(IC2002) reception failure
Flashes 4 times
L: Off
LC-32XL8E/S/RU, LC-37XL8E/S/RU
4 – 23
— MEMO —
LC-32XL8E/S/RU, LC-37XL8E/S/RU
4 – 23
— MEMO —