DOWNLOAD Sharp LC-37GE1E (serv.man6) Service Manual ↓ Size: 2.18 MB | Pages: 14 in PDF or view online for FREE

Model
LC-37GE1E (serv.man6)
Pages
14
Size
2.18 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD / Adjustment Proceedures
File
lc-37ge1e-sm6.pdf
Date

Sharp LC-37GE1E (serv.man6) Service Manual ▷ View online

LC-37GE1E
6 – 5
13.Select the file which you want to upload.
14.Click "Flash" button and get executed.
15.If the Flash has burned successfully, "OK" message is shown as
below.
16.Turn the AC power off , and turn AC power on.
Return to default  automatically.
17.Finish!!
18.Prepare for next model
If you have once write the software to the set, the PC side commu-
nication speed will be set up to "115200".
So before you connect the PC to the next set, please change back
this speed to "9600".
(Please refer 4-(i)-2)
19.Software writing time
It takes about 15 minutes to write the all software with above
method.
Please keep the cable connection during the PC and Set having a
communication.
click once
click once
LC-37GE1E
6 – 6
3. Entering and exiting the adjustment process mode
1. Press the “POWER” key on the set of running TV set to force off the power.
2. While holding down the “VOL(-)” and “MENU” keys on the set at once, press the “POWER” key on the set to turn on the power. The letter 
appears on the screen.
3. Next, hold down the “VOL(-)” and “P(
)” keys on the set at once. Multiple lines of orange  characters appearing on the screen indicate that the
set is  now in the  adjustment Process mode. If you fail to enter the adjustment process mode (the display is the same as normal startup),  retry the
procedure.
4. To exit the adjustment process mode after the adjustment is done, unplug the AC power cord to force off  the power. (When the power is turned off
with the remote controller, once unplug the AC power cord and  plug it in again. In this case, wait 10 seconds or so before plugging.)
5. To remove "K" mode, just repeat steps 1 and 2.  This time the letter "K" disappears from screen.
CAUTION: Use due care in handling the information described here lest the users should  know how to enter the adjustment process mode. If the set-
tings are tampered with in this mode, unrecoverable system damage may result.
4. Remote controller key operation and description of display in adjustment process mode.
1. Key operation
*Input mode is switched automatically when relevant adjustment is started so far as the necessary input signal is available.
2. Description of display
Remote controller key
Main unit key
Function
P(
/
)
—————
Changing a selected line setting (+10/-10)
VOL ( + / - )
VOL ( + / - )
Turning a page (PREVIOUS/NEXT)
Cursor (UP/DOWN)
—————
Moving an item (line) by one (UP/DOWN)
Cursor (LEFT/RIGHT)
—————
Turning a page (PREVIOUS/NEXT)
Changing a selected item setting (+1/-1)
—————
MENU
Direct control on TV set
(Input/Wide Mode/Bright/Contrast)(Not Operative)
INPUT SOURCE
on remote controller
—————
Input source switching (toggle switching)
(TV
→EXT1→EXT2→EXT3→EXT4)(Not Operative)
RETURN
—————
Returning to a present page
OK
—————
Executing a function
K
(1) Current page title
(3) Current page item
[INIT]
[PAL+TUNERMAIN] [COMP] [SCART RGB] [TUNER]
37GE1E ver1.XX XXXX.XX.XX
Dev Version
Center Acutime
Backlight Acutime
XX
Temp Sensor
[2]
[3]
[4]
[5]
Error Standby Cause
[1]
XX
XX
XX
Normal Standby Cause
XX
Main Version
XX
Dev Loader Version
XX
(2) Parameters
LC-37GE1E
6 – 7
5. Adjustment process mode menu
The character string in brackets [  ] will appear as a page title in the adjustment process menu header.
 Page  Line
Item
Description
Remarks (adjustment detail,etc.)
  1/12
  [INFO]
1
 Main Version
  37GE1E ver1.10 2006.0715 
 Main microprocessor version
2
 Dev Version
  ver1.07
 DTV version.
3
 Dev  Loader Version
  2.3
 DTV  Loader Version
4
 Center Acutime
  xxxxH xxM
 Main operating hours
5
 Backlight Acutime
  xxxxH xxM
 Backlight operating hours
6
 Temp Sensor
  091
 Temp Sensor setting
7
 Normal Standby Cause
  1 RC_STANDBY
8
 Error Standby Cause [1]
  [1]  1d FAN ERROR  00H 00M
 Error standby cause Total operating time before error
              [2]
  [2]  1d FAN ERROR  00H 00M
              [3]
  [3]  1d FAN ERROR  00H 00M
              [4]
  [4]  1d FAN ERROR  00H 00M
              [5]
  [5]  1d FAN ERROR  00H 00M
  2/12
 [INIT]
1
  FACTORY INIT
  [EURO]ENTER
 Initialization to factory settings execution
2
  PUBLIC MODE
  off/on
 HOTEL MODE flag setting
3
  Center Acutime Reset
  off/on
 Main operating hours Reset
4
  Backlight Acutime Reset
  off/on
 Backlight operating hours Reset
5
  Picture Read Pos X
  626
 x-axis setting of picture data
6
  Picture Read Pos Y
  419
 y-axis setting of picture data
7
  Picture Read Signal Type
  PAL/COMP/HDMI/RGB
 no used
8
  Picture Read
(0 - 1023)
 Start/stop of picture data
  3/12
[PAL+TUNERMAIN]
1
  RF-AGC BG ADJ
  ENTER
 RF-AGC BG adjustment execution
2
  RF-AGC L ADJ
  ENTER
 RF-AGC L adjustment execution
3
  PAL+TUNER ADJ
  ENTER
 PAL TUNER auto adjustment execution
4
  PAL ADJ
  ENTER
 PAL auto adjustment execution
5
  TUNER ADJ
  ENTER
 TUNER auto adjustment execution
6
  PAL DAC
  29
 PAL DAC adjustment
7
  Tuner A DAC
  32
 Tuner DAC  adjustment
8
  Tuner AGC BG
   0
 Tuner AGC BG adjustment 
9
  Tuner AGC L
   0
 Tuner AGC L adjustment 
10
  Tuner AGC int. offL
   6
 Tuner AGC gain adjustment 
  4/12
 [COMP 15K]
1
 COMP ALL ADJ
  ENTER
 COMP15K auto adjustment execution
2
 COMP CONTRAST
  50
 COMP contrast adjustment execution
3
 COMP Cb GAIN
  32
 COMP Cb gain adjustment execution
4
 COMP Cr GAIN
  32
 COMP Cr gain adjustment execution
5
 COMP BRIGHT
   0
 COMP bright adjustment execution
  5/12
 [SCART RGB]
1
 SCART RGB ALL ADJ
  ENTER
 SCART RGB auto adjustment execution
2
 SCART RGB CONTRAST
  42
 SCART RGB contrast adjustment execution
3
 SCART RGB Cb GAIN
  42
 SCART RGB Cb gain adjustment execution
4
 SCART RGB Cr GAIN
  42
 SCART RGB Cr gain adjustment execution
5
 SCART RGB BRIGHT
   0
 SCART RGB bright adjustment execution
  6/12
[TUNER]
1
  TUNER TEST
  7/12
 [M GAMMA INFO]
1
 M GAMMA POS 1
    4
 W/B adjustment, gradation 1 input setting
2
 M GAMMA POS 2
    9
 W/B adjustment, gradation 2 input setting
3
 M GAMMA POS 3
   14
 W/B adjustment, gradation 3 input setting
4
 M GAMMA POS 4
   19
 W/B adjustment, gradation 4 input setting
5
 M GAMMA POS 5
   24
 W/B adjustment, gradation 5 input setting
6
 M GAMMA POS 6
   29
 W/B adjustment, gradation 6 input setting
7
 M GAMMA WRITE
 off/on
 EEP writing  of  adjustment values
8
 M GAMMA RESET
 off/on
 Initialization of  adjustment values
LC-37GE1E
6 – 8
 8/12
 [M GAMMA 1-3]
1
 M GAMMA R 1
  106
 W/B adjustment, gradation 1R adjustment value
2
 M GAMMA G 1
  106
 W/B adjustment, gradation 1G adjustment value
3
 M GAMMA B 1
  106
 W/B adjustment, gradation 1B adjustment value
4
 M GAMMA R 2  
  271
 W/B adjustment, gradation 2R adjustment value
5
 M GAMMA G 2
  271
 W/B adjustment, gradation 2G adjustment value
6
 M GAMMA B 2
  271
 W/B adjustment, gradation 2B adjustment value
7
 M GAMMA R 3
  448
 W/B adjustment, gradation 3R adjustment value
8
 M GAMMA G 3
  448
 W/B adjustment, gradation 3G adjustment value
9
 M GAMMA B 3
  448
 W/B adjustment, gradation 3B adjustment value
10
 M GAMMA WRITE
 off/on
 EEP writing  of  adjustment values
 9/12
 [M GAMMA 4-6]
1
 M GAMMA R 4
  623
 W/B adjustment, gradation 4R adjustment value
2
 M GAMMA G 4
  623
 W/B adjustment, gradation 4G adjustmnet value
3
 M GAMMA B 4
  623
 W/B adjustment, gradation 4B adjustment value
4
 M GAMMA R 5  
  800
 W/B adjustment, gradation 5R adjustment value
5
 M GAMMA G 5
  800
 W/B adjustment, gradation 5G adjustment value
6
 M GAMMA B 5
  800
 W/B adjustment, gradation 5B adjustment value
7
 M GAMMA R 6
  958
 W/B adjustment, gradation 6R adjustment value
8
 M GAMMA G 6
  958
 W/B adjustment, gradation 6G adjustment value
9
 M GAMMA B 6
  958
 W/B adjustment, gradation 6B adjustment value
10
 M GAMMA WRITE
 off/on
 EEP writing of adjustment values
 10/12
 [ETC]
1
 EEP CLEAR
 off/on
 Clear of process adjustment EEP value
2
 EEP CLEAR B
 off/on
 Clear of process adjustment value of B_mode.
3
 STANDBYCAUSE RESET
 off/on
 Reset of STANDBY CAUSE
4
 AUTO INSTALLATION SW
  0/1
 1:* * *  0: * * *
5
 OPTION 
  0
6
 COUNTRY
 AUTO/EURO/UK
 Destination setting
7
 L ERR RESET
  0
 LAMP ERR RESET  Initialization of L_ERR
8
 L ERR STOP
  0/1
 LAMP ERR Inhibit L_ERR detection.
9
 DTV CLR
 off/on
 Clear of DTV unit.
10
 I2C-OFF
 off/on
 STOP of  I2C DATA execution
 11/12
 [LCD]
1
 OSC FREQ50
  1094
 INVERTER drive frequency setting
2
 OSC FREQ60
  1094
 INVERTER drive frequency setting
3
 PWM FREQ50
  423
 Frequency setting for INVERTER dimmer
4
 PWM FREQ60
  423
Frequency setting for INVERTER dimmer
5
 VCOM ADJ
  64
 12/12
 [LCD TESTPATTERN]
1
 PATTERN
  0
Display LCD test pattern.
Page of 14
Display