3 I2C Method Description
The hardware tools requirement are: 
1. A Parallel port I2C interface with 20 pin to 3 pin cable (Sharp Code: CKIT-0004WJV0).
2 . Make the connections as indicated below:
a. Connect  Parallel port I2C interface to LPT port of the computer.
b. Connect the 20 to 3 pin cable from the I2C interface to the P2306 socket in the main board (XD603).
Before using I2C method is necessary to install Visual I2C software following next procedure.
1. Install Visual I2C release V3.2.3b from file (“Setup_Visual_I2C_v3-2-3b8h.exe”).
•It’s strongly recommended to accept the suggested default folder (“C:\Program Files\Micronas\Visual I2C”).
2. Install Visual I2C VCTp extension from file (“Setup_VI2C_for_VCT6wxyP_v0111.exe”).
•It’s interesting to change default folder to same as Visual I2C (“C:\Program Files\Micronas\Visual I2C”).
•During this installation process is possible to install also a complementary software to manage NVM memories . 
This installation is not needed, for this reason uncheck the option when the setup program ask to you. In case of 
installation it’s interesting to change default folder to same as Visual I2C (“C:\Program Files\Micronas\Visual I2C”).
3. Install Parallel driver depending of your Windows version from existing files inside the Visual I2C installation 
folder “C:\Program Files\Micronas\Visual I2C\Port_Driver”, following next criteria:.
a. Windows 98/Me (“Setup_LptDrv_v0104_9x.exe”).
b. Windows NT (“Setup_LptDrv_v0104_NT_2000.exe”).
c. Windows Xp/2000 (“Setup_LptDrv_v020201_XP_2000.exe”).
After installing Visual I2C, the new generated file structure should look like this:
3.  Install  Parallel  driver  depending  of  your  Windows  version  from  existing  files  inside  the 
Visual I2C installation folder “C:\Program Files\Micronas\Visual I2C\Port_Driver”, following 
next criteria:. 
a.  Windows 98/Me (“Setup_LptDrv_v0104_9x.exe”). 
b.  Windows NT (“Setup_LptDrv_v0104_NT_2000.exe”). 
c.  Windows Xp/2000 (“Setup_LptDrv_v020201_XP_2000.exe”). 
After installing Visual I2C, the new generated file structure should look like this: 
4.  Check  installation  LPT  driver  using  “C:\Program  Files\Micronas\LptDrv\LptDrvTest.exe”.
After run this software, if LPT driver is installed properly must appear this screen: 
�� If the result is not OK, check inside PC bios:  Parallel Port Mode=EPP 
To  run  VCTp  software  updater  program,  please  click  over  “VCTP”  icon  from  “START\All 
programs\Micronas\Visual I2C\IC\VCTP” and after Visual I2C finish their starting process click on 
“TVT”  module.  As  additional  method,  it’s  possible  to  create  a  direct  access  to  “C:\Program 
Files\Micronas\Visual I2C\ic\vct6wxyP\vctq_tvt.vi2c” and launch it from Windows Desktop. 
1
2
3
4
5
7
      To PC
   To P2306
I2C Interface (CKIT-0004WJV0)
 QCNWGA100WJZZ
 QPWBX0004WJZZ
30
 LC-26GA5E
 LC-32GA5E
  LC-32GA9E/LC-32BV9E
  LC-37GA9E/LC-37BV9E
4. Check installation LPT driver using “C:\Program Files\Micronas\LptDrv\LptDrvTest.exe”. After run this software, if 
LPT driver is installed properly must appear this screen:
3.  Install  Parallel  driver  depending  of  your  Windows  version  from  existing  files  inside  the 
Visual I2C installation folder “C:\Program Files\Micronas\Visual I2C\Port_Driver”, following 
next criteria:. 
a.  Windows 98/Me (“Setup_LptDrv_v0104_9x.exe”). 
b.  Windows NT (“Setup_LptDrv_v0104_NT_2000.exe”). 
c.  Windows Xp/2000 (“Setup_LptDrv_v020201_XP_2000.exe”). 
After installing Visual I2C, the new generated file structure should look like this: 
4.  Check  installation  LPT  driver  using  “C:\Program  Files\Micronas\LptDrv\LptDrvTest.exe”.
After run this software, if LPT driver is installed properly must appear this screen: 
�� If the result is not OK, check inside PC bios:  Parallel Port Mode=EPP 
To  run  VCTp  software  updater  program,  please  click  over  “VCTP”  icon  from  “START\All 
programs\Micronas\Visual I2C\IC\VCTP” and after Visual I2C finish their starting process click on 
“TVT”  module.  As  additional  method,  it’s  possible  to  create  a  direct  access  to  “C:\Program 
Files\Micronas\Visual I2C\ic\vct6wxyP\vctq_tvt.vi2c” and launch it from Windows Desktop. 
1
2
3
4
5
7
•If the result is not OK, check inside PC bios:  Parallel Port Mode=EPP
To run VCTp software update program, please click over “VCTP” icon from “START\All programs\Micronas\Visual 
I2C\IC\VCTP” and after Visual I2C finish their starting process click on “TVT” module. As additional method, it’s pos-
sible to create a direct access to “C:\Program Files\Micronas\Visual I2C\ic\vct6wxyP\vctq_tvt.vi2c” and launch it from 
Windows Desktop.
3.  Install  Parallel  driver  depending  of  your  Windows  version  from  existing  files  inside  the 
Visual I2C installation folder “C:\Program Files\Micronas\Visual I2C\Port_Driver”, following 
next criteria:. 
a.  Windows 98/Me (“Setup_LptDrv_v0104_9x.exe”). 
b.  Windows NT (“Setup_LptDrv_v0104_NT_2000.exe”). 
c.  Windows Xp/2000 (“Setup_LptDrv_v020201_XP_2000.exe”). 
After installing Visual I2C, the new generated file structure should look like this: 
4.  Check  installation  LPT  driver  using  “C:\Program  Files\Micronas\LptDrv\LptDrvTest.exe”.
After run this software, if LPT driver is installed properly must appear this screen: 
�� If the result is not OK, check inside PC bios:  Parallel Port Mode=EPP 
To  run  VCTp  software  updater  program,  please  click  over  “VCTP”  icon  from  “START\All 
programs\Micronas\Visual I2C\IC\VCTP” and after Visual I2C finish their starting process click on 
“TVT”  module.  As  additional  method,  it’s  possible  to  create  a  direct  access  to  “C:\Program 
Files\Micronas\Visual I2C\ic\vct6wxyP\vctq_tvt.vi2c” and launch it from Windows Desktop. 
1
2
3
4
5
7
To start updating process follow next instructions:
1. Set Autoread in ON option.
2. Click on “GO” button.
3. Wait until “40” appears in Bootloader Version field.
4. Close DOS pop up windows pressing any key (“Press any key to continue…”.).
5. Click on the “Erase flash” button and wait for a seconds and set the AutoRead to OFF.
6. Check in the desired software version is selected in the “Load BinàFlash” option. If it’s not the correct one, 
please double click on the file name and select it. The first time this software is use it’s necessary to confirm write 
Addressing margin as from 0x0 to 0x7ffff.
31
 LC-26GA5E
 LC-32GA5E
  LC-32GA9E/LC-32BV9E
  LC-37GA9E/LC-37BV9E
To start updating process follow next instructions. 
1.  Set Autoread in ON option. 
2.  Click on “GO” button. 
3.  Wait until “40” appears in Bootloader Version field. 
4.  Close DOS popup windows pressing any key (“Press any key to continue…”.). 
5.  Click on the “Erase flash” button and wait for a seconds and set the AutoRead to OFF. 
6.  Check in the desired software version is selected in the “Load Bin�Flash” option. If it’s 
not the correct one, please double click on the file name and select it. The first time this 
software is use it’s necessary to confirm writte Addressing margin as from 0x0 to 0x7ffff. 
7.  Click on the “Load Bin � Flash” to start updating process. 
8.  When the updating process finishes, the “Progress” popup window automatically closes. 
If  appears  some  problem  during  the  updating  process  a  error  label  appears  in  the 
filename information line. 
�� If  the  TV  has  problem  to  enters  in  the  “Bootloader  mode”,  it’s  possible  to  force  it  by 
hardware method. This alternative method is described below: 
1.  Switch off TV set or hold VCTp RESET line to GND. 
2.  Pull down SCL line (pin 1) to GND (pin 3) in P2306 connector. 
3.  Switch on TV set  or release VCTp RESET line. 
4.  Release SCL pull down after minimum of 2 seconds. 
5.  Check if VCTp is in bootloader mode with Autoread setting in ON. 
6.  Wait until “40” appears in Bootloader Version field. 
7.  Follow instruction from item 5 on software method. 
�� Sometimes,  depending  on  the  PC  hardware,  the  progress  bar  runs  very  fast  (Normal 
time:  1  minute)  or  some  error  message  appears  in  the  filename  information  line.  This 
means it’s necessary to modify some parameter of LPT port, for this reason select “LPT 
Preferences” on the “File\Preferences…” menu and increase Delay from “0” to “
1” or “2
(normally, these values are the best choice). 
7. Click on the “Load Bin à Flash” to start updating process.
To start updating process follow next instructions. 
1.  Set Autoread in ON option. 
2.  Click on “GO” button. 
3.  Wait until “40” appears in Bootloader Version field. 
4.  Close DOS popup windows pressing any key (“Press any key to continue…”.). 
5.  Click on the “Erase flash” button and wait for a seconds and set the AutoRead to OFF. 
6.  Check in the desired software version is selected in the “Load Bin�Flash” option. If it’s 
not the correct one, please double click on the file name and select it. The first time this 
software is use it’s necessary to confirm writte Addressing margin as from 0x0 to 0x7ffff. 
7.  Click on the “Load Bin � Flash” to start updating process. 
8.  When the updating process finishes, the “Progress” popup window automatically closes. 
If  appears  some  problem  during  the  updating  process  a  error  label  appears  in  the 
filename information line. 
�� If  the  TV  has  problem  to  enters  in  the  “Bootloader  mode”,  it’s  possible  to  force  it  by 
hardware method. This alternative method is described below: 
1.  Switch off TV set or hold VCTp RESET line to GND. 
2.  Pull down SCL line (pin 1) to GND (pin 3) in P2306 connector. 
3.  Switch on TV set  or release VCTp RESET line. 
4.  Release SCL pull down after minimum of 2 seconds. 
5.  Check if VCTp is in bootloader mode with Autoread setting in ON. 
6.  Wait until “40” appears in Bootloader Version field. 
7.  Follow instruction from item 5 on software method. 
�� Sometimes,  depending  on  the  PC  hardware,  the  progress  bar  runs  very  fast  (Normal 
time:  1  minute)  or  some  error  message  appears  in  the  filename  information  line.  This 
means it’s necessary to modify some parameter of LPT port, for this reason select “LPT 
Preferences” on the “File\Preferences…” menu and increase Delay from “0” to “
1” or “2
(normally, these values are the best choice). 
8. When the updating process finishes, the “Progress” pop up window automatically closes. If appears some problem 
during the updating process a error label appears in the filename information line.
If the TV has problem to enters in the “Bootloader mode”, it’s possible to force it by hardware method. This alternative 
method is described below:
1.Switch off TV set or hold VCTp RESET line to GND.
2.Pull down SCL line (pin 1) to GND (pin 3) in P2306 connector.
3.Switch on TV set  or release VCTp RESET line.
4.Release SCL pull down after minimum of 2 seconds.
5.Check if VCTp is in bootloader mode with Autoread setting in ON.
6.Wait until “40” appears in Bootloader Version field.
7.Follow instruction from item 5 on software method.
Sometimes, depending on the PC hardware, the progress bar runs very fast (Normal time: 1 minute) or some error mes-
sage appears in the filename information line. This means it’s necessary to modify some parameter of LPT port, for this 
reason select “LPT Preferences” on the “File\Preferences…” menu and increase Delay from “0” to “1” or “2” (normally, 
these values are the best choice).
RS-232C METHOD DESCRIPTION. 
The hardware tools requirement are: 
1.  A Modem-null (Cross type) DB9 female to DB9 female cable. 
2.  An adaptor DB9 male to mini-Din 9 pin male cable (Sharp Code: QCNWGA015WJPZ) 
3.  Make the connections as indicated in the figure: 
Before  using  RS-232C  updating  method  is  necessary  to  configure  a  Terminal  PC  software. 
HyperTerminal  has  been  selected  as  a  Terminal  software  because  it’s  include  in  all  Windows 
versions  as  an  accessory,  and  you  can  find  it  inside  “Accessories\Communications”  folder.  For 
this reason, please follow carefully the next steps: 
1.  First  time  HyperTerminal  is  used,  it’s  necessary  to 
configure some settings. Follows next action to configure 
two  connection:  low  speed  (9600bps)  and  high  speed 
(115200bps).
2.  Create a New Connection file with name “P55_9600bps”. 
3.  Select  a  free  COM  port    and  select  the  Port  Settings 
properties as follows: 
Computer 
TV set
31
 LC-26GA5E
 LC-32GA5E
  LC-32GA9E/LC-32BV9E
  LC-37GA9E/LC-37BV9E
To start updating process follow next instructions. 
1.  Set Autoread in ON option. 
2.  Click on “GO” button. 
3.  Wait until “40” appears in Bootloader Version field. 
4.  Close DOS popup windows pressing any key (“Press any key to continue…”.). 
5.  Click on the “Erase flash” button and wait for a seconds and set the AutoRead to OFF. 
6.  Check in the desired software version is selected in the “Load Bin�Flash” option. If it’s 
not the correct one, please double click on the file name and select it. The first time this 
software is use it’s necessary to confirm writte Addressing margin as from 0x0 to 0x7ffff. 
7.  Click on the “Load Bin � Flash” to start updating process. 
8.  When the updating process finishes, the “Progress” popup window automatically closes. 
If  appears  some  problem  during  the  updating  process  a  error  label  appears  in  the 
filename information line. 
�� If  the  TV  has  problem  to  enters  in  the  “Bootloader  mode”,  it’s  possible  to  force  it  by 
hardware method. This alternative method is described below: 
1.  Switch off TV set or hold VCTp RESET line to GND. 
2.  Pull down SCL line (pin 1) to GND (pin 3) in P2306 connector. 
3.  Switch on TV set  or release VCTp RESET line. 
4.  Release SCL pull down after minimum of 2 seconds. 
5.  Check if VCTp is in bootloader mode with Autoread setting in ON. 
6.  Wait until “40” appears in Bootloader Version field. 
7.  Follow instruction from item 5 on software method. 
�� Sometimes,  depending  on  the  PC  hardware,  the  progress  bar  runs  very  fast  (Normal 
time:  1  minute)  or  some  error  message  appears  in  the  filename  information  line.  This 
means it’s necessary to modify some parameter of LPT port, for this reason select “LPT 
Preferences” on the “File\Preferences…” menu and increase Delay from “0” to “
1” or “2
(normally, these values are the best choice). 
7. Click on the “Load Bin à Flash” to start updating process.
To start updating process follow next instructions. 
1.  Set Autoread in ON option. 
2.  Click on “GO” button. 
3.  Wait until “40” appears in Bootloader Version field. 
4.  Close DOS popup windows pressing any key (“Press any key to continue…”.). 
5.  Click on the “Erase flash” button and wait for a seconds and set the AutoRead to OFF. 
6.  Check in the desired software version is selected in the “Load Bin�Flash” option. If it’s 
not the correct one, please double click on the file name and select it. The first time this 
software is use it’s necessary to confirm writte Addressing margin as from 0x0 to 0x7ffff. 
7.  Click on the “Load Bin � Flash” to start updating process. 
8.  When the updating process finishes, the “Progress” popup window automatically closes. 
If  appears  some  problem  during  the  updating  process  a  error  label  appears  in  the 
filename information line. 
�� If  the  TV  has  problem  to  enters  in  the  “Bootloader  mode”,  it’s  possible  to  force  it  by 
hardware method. This alternative method is described below: 
1.  Switch off TV set or hold VCTp RESET line to GND. 
2.  Pull down SCL line (pin 1) to GND (pin 3) in P2306 connector. 
3.  Switch on TV set  or release VCTp RESET line. 
4.  Release SCL pull down after minimum of 2 seconds. 
5.  Check if VCTp is in bootloader mode with Autoread setting in ON. 
6.  Wait until “40” appears in Bootloader Version field. 
7.  Follow instruction from item 5 on software method. 
�� Sometimes,  depending  on  the  PC  hardware,  the  progress  bar  runs  very  fast  (Normal 
time:  1  minute)  or  some  error  message  appears  in  the  filename  information  line.  This 
means it’s necessary to modify some parameter of LPT port, for this reason select “LPT 
Preferences” on the “File\Preferences…” menu and increase Delay from “0” to “
1” or “2
(normally, these values are the best choice). 
8. When the updating process finishes, the “Progress” pop up window automatically closes. If appears some problem 
during the updating process a error label appears in the filename information line.
If the TV has problem to enters in the “Bootloader mode”, it’s possible to force it by hardware method. This alternative 
method is described below:
1.Switch off TV set or hold VCTp RESET line to GND.
2.Pull down SCL line (pin 1) to GND (pin 3) in P2306 connector.
3.Switch on TV set  or release VCTp RESET line.
4.Release SCL pull down after minimum of 2 seconds.
5.Check if VCTp is in bootloader mode with Autoread setting in ON.
6.Wait until “40” appears in Bootloader Version field.
7.Follow instruction from item 5 on software method.
Sometimes, depending on the PC hardware, the progress bar runs very fast (Normal time: 1 minute) or some error mes-
sage appears in the filename information line. This means it’s necessary to modify some parameter of LPT port, for this 
reason select “LPT Preferences” on the “File\Preferences…” menu and increase Delay from “0” to “1” or “2” (normally, 
these values are the best choice).
RS-232C METHOD DESCRIPTION. 
The hardware tools requirement are: 
1.  A Modem-null (Cross type) DB9 female to DB9 female cable. 
2.  An adaptor DB9 male to mini-Din 9 pin male cable (Sharp Code: QCNWGA015WJPZ) 
3.  Make the connections as indicated in the figure: 
Before  using  RS-232C  updating  method  is  necessary  to  configure  a  Terminal  PC  software. 
HyperTerminal  has  been  selected  as  a  Terminal  software  because  it’s  include  in  all  Windows 
versions  as  an  accessory,  and  you  can  find  it  inside  “Accessories\Communications”  folder.  For 
this reason, please follow carefully the next steps: 
1.  First  time  HyperTerminal  is  used,  it’s  necessary  to 
configure some settings. Follows next action to configure 
two  connection:  low  speed  (9600bps)  and  high  speed 
(115200bps).
2.  Create a New Connection file with name “P55_9600bps”. 
3.  Select  a  free  COM  port    and  select  the  Port  Settings 
properties as follows: 
Computer 
TV set
Page of 10