Sharp LC-37GA9EK (serv.man7) Service Manual ▷ View online
27
LC-26GA5E
LC-32GA5E
LC-32GA9E/LC-32BV9E
LC-37GA9E/LC-37BV9E
6. Check the connection between TV set and PC, sending a wrong command, as for example: “aaa”. TV set returns
an “err” label as an syntaxes ERROR (Not correct order or sequence).
Send a “DWMD” (capital letters) command to enter TV set in Download Mode.
Change a baud rate to 115200.
Select:
Setup ⇒ Baud rate ⇒ 115200 ⇒ O.K.
Select Setup � serial port � O.K.
Appear a follow screen.
Appear a follow screen.
Select a follow settings:
Serial port to use: COM x
Baud rate: 9600
Data: 8 bits
Parity : none
Stop: 1 bit
Flow control: none
Click O.K.
Serial port to use: COM x
Baud rate: 9600
Data: 8 bits
Parity : none
Stop: 1 bit
Flow control: none
Click O.K.
5. Select follows settings:
Serial port to use: COM x
Baud rate:
9600
Data:
8 bits
Parity:
none
Stop:
1 bit
Flow control:
none
Enter O.K.
Check the connection between TV set and PC, sending a wrong command, as for
example: “aaa”. TV set returns an “err” label as an syntaxis ERROR (Not correct order
or sequence).
example: “aaa”. TV set returns an “err” label as an syntaxis ERROR (Not correct order
or sequence).
Send a “DWMD” (capital letters) command to enter TV set in Download Mode.
Change a baud rate to 115200.
Select setup � baud rate � 115200 � O.K.
Change a baud rate to 115200.
Select setup � baud rate � 115200 � O.K.
Select to File � transfer � XMODEM � sent
Check the connection between TV set and PC, sending a wrong command, as for
example: “aaa”. TV set returns an “err” label as an syntaxis ERROR (Not correct order
or sequence).
example: “aaa”. TV set returns an “err” label as an syntaxis ERROR (Not correct order
or sequence).
Send a “DWMD” (capital letters) command to enter TV set in Download Mode.
Change a baud rate to 115200.
Select setup � baud rate � 115200 � O.K.
Change a baud rate to 115200.
Select setup � baud rate � 115200 � O.K.
Select to File � transfer � XMODEM � sent
7. Select:
File ⇒ Transfer ⇒ XMODEM ⇒ Sent
Choose the file for upgrade and push “open”.
.
After press “Open” button the upgrade process starts as follows:
28
LC-26GA5E
LC-32GA5E
LC-32GA9E/LC-32BV9E
LC-37GA9E/LC-37BV9E
9. After select “Open” the upgrade process starts as follows:
VERY IMPORTANT NOTE:
During the updating time, please don’t use the PC for other purposes, in order to abolish communication prob-
lems between TV set and PC. If TV set was not updated properly, the TV won’t have the software to startup
again, and you must follow the “I2C method” to update another time the TV set.
again, and you must follow the “I2C method” to update another time the TV set.
8. Choose the file for upgrade and click “Open”.
Choose the file for upgrade and push “open”.
.
After press “Open” button the upgrade process starts as follows:
When flash update process finishes, the ” Flash programming complete “ label
appear in the screen , the device automatically go to switch off, and in a few seconds go
to switch on again.
to switch on again.
Enter in service mode and check the main soft version.
VERY IMPORTANT NOTE: Seguir con el service manual actual
10. When flash update process finishes, the ” Flash programming complete “ label appear in the screen , the device
automatically go to switch off, and in a few seconds go to switch on again.
When flash update process finishes, the ” Flash programming complete “ label
appear in the screen , the device automatically go to switch off, and in a few seconds go
to switch on again.
to switch on again.
Enter in service mode and check the main soft version.
VERY IMPORTANT NOTE: Seguir con el service manual actual
29
LC-26GA5E
LC-32GA5E
LC-32GA9E/LC-32BV9E
LC-37GA9E/LC-37BV9E
3 I2C Method Description
The hardware tools requirement are:
1. A Parallel port I2C interface with 20 pin to 3 pin cable (Sharp Code: CKIT-0004WJV0).
2 . Make the connections as indicated below:
2 . Make the connections as indicated below:
a. Connect Parallel port I2C interface to LPT port of the computer.
b. Connect the 20 to 3 pin cable from the I2C interface to the P2306 socket in the main board (XD603).
b. Connect the 20 to 3 pin cable from the I2C interface to the P2306 socket in the main board (XD603).
Before using I2C method is necessary to install Visual I2C software following next procedure.
1. Install Visual I2C release V3.2.3b from file (“Setup_Visual_I2C_v3-2-3b8h.exe”).
•It’s strongly recommended to accept the suggested default folder (“C:\Program Files\Micronas\Visual I2C”).
2. Install Visual I2C VCTp extension from file (“Setup_VI2C_for_VCT6wxyP_v0111.exe”).
•It’s interesting to change default folder to same as Visual I2C (“C:\Program Files\Micronas\Visual I2C”).
•During this installation process is possible to install also a complementary software to manage NVM memories .
This installation is not needed, for this reason uncheck the option when the setup program ask to you. In case of
installation it’s interesting to change default folder to same as Visual I2C (“C:\Program Files\Micronas\Visual I2C”).
3. Install Parallel driver depending of your Windows version from existing files inside the Visual I2C installation
folder “C:\Program Files\Micronas\Visual I2C\Port_Driver”, following next criteria:.
a. Windows 98/Me (“Setup_LptDrv_v0104_9x.exe”).
b. Windows NT (“Setup_LptDrv_v0104_NT_2000.exe”).
c. Windows Xp/2000 (“Setup_LptDrv_v020201_XP_2000.exe”).
After installing Visual I2C, the new generated file structure should look like this:
3. Install Parallel driver depending of your Windows version from existing files inside the
Visual I2C installation folder “C:\Program Files\Micronas\Visual I2C\Port_Driver”, following
next criteria:.
a. Windows 98/Me (“Setup_LptDrv_v0104_9x.exe”).
b. Windows NT (“Setup_LptDrv_v0104_NT_2000.exe”).
c. Windows Xp/2000 (“Setup_LptDrv_v020201_XP_2000.exe”).
After installing Visual I2C, the new generated file structure should look like this:
4. Check installation LPT driver using “C:\Program Files\Micronas\LptDrv\LptDrvTest.exe”.
After run this software, if LPT driver is installed properly must appear this screen:
�� If the result is not OK, check inside PC bios: Parallel Port Mode=EPP
To run VCTp software updater program, please click over “VCTP” icon from “START\All
programs\Micronas\Visual I2C\IC\VCTP” and after Visual I2C finish their starting process click on
“TVT” module. As additional method, it’s possible to create a direct access to “C:\Program
Files\Micronas\Visual I2C\ic\vct6wxyP\vctq_tvt.vi2c” and launch it from Windows Desktop.
1
2
3
4
5
6
7
To PC
To P2306
I2C Interface (CKIT-0004WJV0)
QCNWGA100WJZZ
QPWBX0004WJZZ
30
LC-26GA5E
LC-32GA5E
LC-32GA9E/LC-32BV9E
LC-37GA9E/LC-37BV9E
4. Check installation LPT driver using “C:\Program Files\Micronas\LptDrv\LptDrvTest.exe”. After run this software, if
LPT driver is installed properly must appear this screen:
3. Install Parallel driver depending of your Windows version from existing files inside the
Visual I2C installation folder “C:\Program Files\Micronas\Visual I2C\Port_Driver”, following
next criteria:.
a. Windows 98/Me (“Setup_LptDrv_v0104_9x.exe”).
b. Windows NT (“Setup_LptDrv_v0104_NT_2000.exe”).
c. Windows Xp/2000 (“Setup_LptDrv_v020201_XP_2000.exe”).
After installing Visual I2C, the new generated file structure should look like this:
4. Check installation LPT driver using “C:\Program Files\Micronas\LptDrv\LptDrvTest.exe”.
After run this software, if LPT driver is installed properly must appear this screen:
�� If the result is not OK, check inside PC bios: Parallel Port Mode=EPP
To run VCTp software updater program, please click over “VCTP” icon from “START\All
programs\Micronas\Visual I2C\IC\VCTP” and after Visual I2C finish their starting process click on
“TVT” module. As additional method, it’s possible to create a direct access to “C:\Program
Files\Micronas\Visual I2C\ic\vct6wxyP\vctq_tvt.vi2c” and launch it from Windows Desktop.
1
2
3
4
5
6
7
•If the result is not OK, check inside PC bios: Parallel Port Mode=EPP
To run VCTp software update program, please click over “VCTP” icon from “START\All programs\Micronas\Visual
I2C\IC\VCTP” and after Visual I2C finish their starting process click on “TVT” module. As additional method, it’s pos-
sible to create a direct access to “C:\Program Files\Micronas\Visual I2C\ic\vct6wxyP\vctq_tvt.vi2c” and launch it from
Windows Desktop.
3. Install Parallel driver depending of your Windows version from existing files inside the
Visual I2C installation folder “C:\Program Files\Micronas\Visual I2C\Port_Driver”, following
next criteria:.
a. Windows 98/Me (“Setup_LptDrv_v0104_9x.exe”).
b. Windows NT (“Setup_LptDrv_v0104_NT_2000.exe”).
c. Windows Xp/2000 (“Setup_LptDrv_v020201_XP_2000.exe”).
After installing Visual I2C, the new generated file structure should look like this:
4. Check installation LPT driver using “C:\Program Files\Micronas\LptDrv\LptDrvTest.exe”.
After run this software, if LPT driver is installed properly must appear this screen:
�� If the result is not OK, check inside PC bios: Parallel Port Mode=EPP
To run VCTp software updater program, please click over “VCTP” icon from “START\All
programs\Micronas\Visual I2C\IC\VCTP” and after Visual I2C finish their starting process click on
“TVT” module. As additional method, it’s possible to create a direct access to “C:\Program
Files\Micronas\Visual I2C\ic\vct6wxyP\vctq_tvt.vi2c” and launch it from Windows Desktop.
1
2
3
4
5
6
7
To start updating process follow next instructions:
1. Set Autoread in ON option.
2. Click on “GO” button.
3. Wait until “40” appears in Bootloader Version field.
4. Close DOS pop up windows pressing any key (“Press any key to continue…”.).
5. Click on the “Erase flash” button and wait for a seconds and set the AutoRead to OFF.
6. Check in the desired software version is selected in the “Load BinàFlash” option. If it’s not the correct one,
please double click on the file name and select it. The first time this software is use it’s necessary to confirm write
Addressing margin as from 0x0 to 0x7ffff.