DOWNLOAD Sharp LC-32SD1E (serv.man7) Service Manual ↓ Size: 6.06 MB | Pages: 27 in PDF or view online for FREE

Model
LC-32SD1E (serv.man7)
Pages
27
Size
6.06 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD / Adjustment Procedure
File
lc-32sd1e-sm7.pdf
Date

Sharp LC-32SD1E (serv.man7) Service Manual ▷ View online

LC-26SD1E/RU, LC-32SD1E/RU
5 – 17
7. First of all, select copy target drive and then use Drag & drop for the “.img” file.
8. Wait, copy is in process.
9. Copy is finished, when the Copying progress bar disappears and the name of data file appears in the File Box.
LC-26SD1E/RU, LC-32SD1E/RU
5 – 18
10. Close SMM application.
11. Remove PCMCIA safely using the Windows Task bar pop up menu (Right-click over the Tray Icon).
12. Now, the PCMCIA-CF card is prepared to update the TV set.
Procedure to update the TV Set using PCMCIA-CF Card:
1. Switch Off the LCD TV Set.
2. Insert PCMCIA Card (already prepared according the details before given at “How to prepare the CF Card using the “Storage Media Manager
1.0.1” (SMM))”.
3. Switch On the LCD TV Set (it starts automatically the updating, Items #1 to #4).
4. Wait till the finishing indication is shown.
5. For checking the correct update, please Select DTV Menu on TV Set. The following On Screen Display will appear.
6. Select “Version”. The updated version can be verified.
LC-26SD1E/RU, LC-32SD1E/RU
5 – 19
[3] Entering and exiting the adjustment process mode
1) Unplug the AC power cord of running TV set to force off the power.
2) While holding down the “VOL(-)” and ”INPUT” keys on the set at once, plug in the AC power cord to turn on the power. The letter  
appears 
on
the screen.
3) Next, hold down the ”VOL(-)” and ”P(
)” keys on the set at once.
Multiple lines of orange  characters appearing on the screen indicate that the set is  now in the adjustment Process mode. If you fail to enter the
adjustment process mode (the display is the same as normal startup),  retry the procedure.
4) To exit the adjustment process mode after the adjustment is done, unplug the AC power cord to force off the power. (When the power is turned off
with the remote controller, once unplug the AC power cord and plug it in again. In this case, wait 10 seconds or so before plugging.)
5) To remove “K” mode, just repeat steps 1 and 2. This time the letter K disappears from screen.
[4] Remote controller key operation and description of display in adjustment process mode.
1. key operation
* Input mode is switched automatically when relevant adjustment is started so far as the necessary input signal is available.
2. Description of display
Caution :
Use due care in handling the information described here lest the users should  know how to enter the adjustment process mode. If the 
settings are tampered with in this mode, unrecoverable system damage may result.
Remote controller key
Main unit key
Function
P (
 /
)
P (
 /
)
Moving an item (line) by one (UP/DOWN)
VOL (+ / –)
VOL (+ / –)
Changing a selected item setting (+1/–1)
Cursor (UP/DOWN)
——————
Turing a page (PREVIOUS/NEXT)
Cursor (LEFT/RIGHT)
——————
Changing a selected line setting (+10/–10)
INPUT SOURCE
on remote controller
INPUT button
Input source switching (toggle switching)
(TV
→EXT1→EXT2→EXT3→EXT4→EXT5)
(Not Operative)
OK
——————
Executing a function
K
(1) Current page/Total pages (3) Currently selected input
(4) Current colour TV system
(5) Destination
Inch Setting
(32 just as example,
it may be: --/32/37)
1/11
[INFO]
TV
AUTO
32:EURO
Dev Version
Pic Version
TEMP SENSOR
Dev Loader Version
Adjustment process
menu header
(7) Parameters
1.XX (XX/XX/XXX)
(2) Current page title
NORMAL STANDBY CAUSE
ERROR STANDBY CAUSE
XX
XX
XX
XX
Main Version
XX
XX
LC-26SD1E/RU, LC-32SD1E/RU
5 – 20
[5] Adjustment process mode menu
The character string in brackets [     ] will appear as a page title in the adjustment process menu header.
Page
 Line
Item
Description
Remarks (adjustment detail, etc.)
1/11
[INFO]
1
Main Version
LEW05 00.03(2006/07/15x)5
Main microprocessor version
2
Dev  Version
xxxxxx
DTV microprocessor version
3
Dev  Loader Version
xxxxxx
DTV microprocessor-Loader version
4
Pic Version
xxxxxx
Pic MICON version
5
TEMP SENSOR
xxxxxx
6
NORMAL STANDBY CAUSE 1 RC_STANDBY
7
ERROR STANDBY CAUSE
[1] 0      00H 00M
Error standby cause Total operating time before error
[2] 0      00H 00M
[3] 0      00H 00M
[4] 0      00H 00M
[5] 0      00H 00M
2/11
[INIT]
1
Factory Init
(--/EURO/UK/ITALY/FRANCE/
RUSSIA)ENTER
Initialization to factory settings execution
2
Inch Setting
(--/26/32/37/45)
Inch present setting
3
Public Mode
OFF/ON
HOTEL MODE flag setting
4
Center Acutime
xxH xxM
Main operating hours
5
RESET
OFF/ON
Main operating hours reset
6
Backlight Acutime
xxH xxM
Backlight operating hours
7
RESET
OFF/ON
Backlight operating hours reset
8
 Picture Read Pos X
0-xxx
x-axis setting of picture data
9
Picture Read Pos Y
0-xxx
y-axis setting of picture data
10
Picture Read
ON/OFF
Start/stop of picture data
3/11
[PAL.SECAM. N358]
1
RF-AGC ADJ
ENTER
RF-AGC auto adjustment execution
2
PAL+TUNER ADJ
ENTER
PAL TUNER auto adjustment execution
3
PAL ADJ
ENTER
PAL auto adjustment execution
4
TUNER ADJ
ENTER
TUNER auto adjustment execution
5
CONTRAST SD
32
PAL contrast adjustment
6
SECAM CB OFFSET
1
SECAM offset adjustment
7
SECAM CR OFFSET
1
SECAM offset adjustment
8
TUNER A DAC
32
TUNER DAC  adjustment
9
RF AGC
20
RF AGC adjustment
4/11
[COMP 15K]
1
COMP 15K ADJ
ENTER
COMP15K auto adjustment execution
2
COMP 15K CONTRAST
32
Contrast adjustment
5/11
[HDTV]
1
HDTV CONTRAST
32
HDTV Contrast adjustment
6/11
[SMPTE]
1
RF-AGC ADJ
ENTER
RF-AGC auto adjustment execution
2
PAL+TUNER ADJ
ENTER
PAL TUNER auto adjustment execution
3
PAL ADJ
ENTER
PAL auto adjustment execution
4
TUNER ADJ
ENTER
TUNER auto adjustment execution
5
CONTRAST SD
32
PAL contrast adjustment
6
SECAM CB OFFSET
1
SECAM offset adjustment
7
SECAM CR OFFSET
1
SECAM offset adjustment
8
TUNER A DAC
34
TUNER DAC  adjustment
9
RF AGC
25
RF AGC adjustment
7/11
[M GAMMA INFO]
1
M GAMMA IN 1
160
W/B adjustment, gradation 1 input setting
2
M GAMMA IN 2
320
W/B adjustment, gradation 2 input setting
3
M GAMMA IN 3
480
W/B adjustment, gradation 3 input setting
4
M GAMMA IN 4
640
W/B adjustment, gradation 4 input setting
5
M GAMMA IN 5
800
W/B adjustment, gradation 5 input setting
6
M GAMMA IN 6
960
W/B adjustment, gradation 6 input setting
7
M GAMMA WRITE
OFF/ON
EEP writing  of  adjustment values
8
M GAMMA RESET
OFF/ON
Initialization of  adjustment values
Page of 27
Display