<During external connection> No picture on the monitor (3) 
                                            
No picture from EXT1 appears on EXT2-connected monitor. 
Is CVBS signal output into pin (19) of EXT2 (SC502)?
YES
Check the setting of an external input device that connects with 
EXT2.
NO
Is CVBS signal input to pin(1) of IC508 from pin(AJ24/
CVBS_MONI_OUT) of IC3302 
(Digital AV decode & Main CPU)? 
YES
Check the IC508 and their peripheral circuits.
NO
Is CVBS signal sent to pin(AG29/SC1_CVBS/Y) of IC3302
 (Digital AV decode & Main CPU) from EXT1(SC503)? 
YES
Check the IC3302 and their peripheral circuits.
NO
Is CVBS signal sent to pin (20) of EXT1(SC503)? 
YES
Check the line between EXT1(SC503) and IC3302.
NO
Check the setting of an external input device that connects with 
EXT1.
<During external connection> No picture on the monitor (4) 
                                            
No picture from EXT8 appears on EXT2- connected monitor. 
Is CVBS signal output into pin(19) of EXT2 (SC502)?
YES
Check the setting of an external input device that connects with 
EXT2.
NO
Is CVBS signal input to pin(1) of IC508 from pin(AJ24/
CVBS_MONI_OUT) of IC3302 
(Digital AV decode & Main CPU)? 
YES
Check the IC508 and their peripheral circuits.
NO
Is CVBS signal input to pin (AE29/CVBS__IN) of IC3302 from 
J505? 
YES
Check the IC3302 and their peripheral circuits.
NO
Is CVBS signal sent to pin (6) of EXT8(J505)? 
YES
Check the line between EXT8(J505) and IC3302.
NO
Is V3_PLUG detection signal input to pin (AJ11/CVBS/PLUG) of 
IC3302 from pin(7) of EXT8 (J505)? 
YES
Check the line between EXT8(J505) and IC3302.
NO
Check the setting of an external input device that connects with 
EXT8.
LC-32/40/46LE700E/RU/S,LU700E/S,LX700E/RU,LC-52LE700E/RU/S
6 – 18
LCD failure (1)
Does a single or several 
vertical stripes appear 
on the LCD screen? 
Does a single or several 
horizontal stripes appear 
on the LCD screen?
Do luminescent or black 
dots appear on the 
screen?
 Is the on-screen image 
rippling or distorted?
Is there any portion 
which some screens 
were darkish or 
became whitish?
Replace the LCD panel.
LCD failure (2)
The backlight func-
tions. Does not the 
image come out in the 
LCD screen 
(screen black)?
Does the entire LCD 
screen look whitish all 
over?
Does the QS drive func-
tion?
 Are the data bit drop-
out?
(No solution even when 
turning on and off the QS 
drive)
Is the gamma correc-
tion as specified?
Replace the LCD_CONT_UNIT.
LC-32/40/46LE700E/RU/S,LU700E/S,LX700E/RU,LC-52LE700E/RU/S
6 – 19
[2] LED flashing specification at the time of the error
Display method
• Refer to Table 1.
• Make the OPC LED flash using the [MENU] key on the remote control since the display for service persons is identified by the number of flashings
(once to 5 times).
Even if the [MENU] key is pressed again, it does not return to the display for customers (only the power LED flashes).
• After recovering from an error, if the same error cannot be generated again, refer to MONITOR ERR CAUSE on the adjustment process screen.
LED flashing method
• Synchronize the phases of the power LED and OPC LED.
• If the LEDs have different number of flashings, adjust the flashing cycle to that where the LED flashes more times.
Table 1. Concrete flashing pattern
* 1: For details, refer to ERROR STANDBY CAUSE on the adjustment process screen.
* 2: If the boot section is abnormal, there is no flashing (flashing disabled).
<Flashing example for customers>
Power
<Flashing example for service persons>
Power
OPC
(Displayed by the 
specific operation)
Item
For customers
For service persons
Cause
Power
OPC
Power
OPC
Inverter/Lamp system failure  Red flashes once 
Off 
Red flashes once 
Flashes once 
Lamp error
Power PWB failure (Power
Red flashes once 
Off 
Red flashes once 
Flashes once 
AC_DET error
failure, etc.)
Flashes twice 
UR+13.5V error
Flashes 3 times 
D3.3V error
Flashes 5 times 
Panel power supply error
Main PWB failure 
Green flashes once 
Off 
Green flashes once 
Flashes once 
Initial communication error
(Communication failure, etc.) 
Flashes twice 
Start-up confirmation 
communication error
Flashes 3 times 
Regular communication error
Flashes 5 times 
Other communication error
Others 
Green flashes twice 
Off 
Green flashes twice
 Flashes once 
Temperature error
Flashes twice 
Sync error
Flashes 3 times 
Notification from the main
microprocessor (*1)
VerUP executing 
Orange flashes once  Off 
Orange flashes once  Off 
Version upgrading
VerUP succeeded 
Power green/OPC flash alternately  Power green/OPC flash alternately 
Version upgrade succeeded
VerUP failed 
Green/Red flash
Off 
Green/Red flash
Off 
Version upgrade failed
alternately
alternately
System 
Red flashes 3 times
Off 
Red flashes 3 times 
Off 
Mounting discrimination 
connector unplugged
ROM data failure 
Green/Red flash
Off 
Green/Red flash
Start-up after failing version
alternately
alternately
upgrade (*2)
300ms
300ms
1500ms
300ms
300ms
1500ms
LC-32/40/46LE700E/RU/S,LU700E/S,LX700E/RU,LC-52LE700E/RU/S
6 – 20
MONITOR ERR STBY table
LED flashing timing chart at the time of the error
1) Power LED
 2) Inverter/Lamp failure details (Power red LED flashes once and OPC (preset) LED flashes)
Outline: Communication/Power failure detected by the monitor microprocessor (IC2002) is stored on EEPROM,
states can be confirmed in the adjustment process mode.
Location: Page 1/16 of the adjustment process mode: MONITOR ERR CAUSE
“0” if there is no error. It is cleared to 0 on the last page of the adjustment process mode.
Display Error 
description
02
Start-up communication error 2 
Initial communication from the main CPU is not received.
03
Start-up communication error 3 
Only the initial communication is received.
04
Start-up communication error 4
Until panel information request reception
05
Start-up communication error 5
Until initialization completion reception
06
Start-up communication error 6
Until version notification transmission
07
Start-up communication error 7
Until start-up information notification transmission
08
Start-up communication error 8
Until start-up information response reception
09
Start-up communication error 9
Until time-out setting reception
0A
Communication error A 
REQ time-out
0B
Communication error B 
Restart time-out during the beginning of time acquisition start-up
0C
Communication error C 
Ending sequence time-out
0D
Communication error D 
Preset start-up time-out during completion
0E
Communication error E 
Download start-up time-out
0F
Communication error F 
Time acquisition time-out
11
 Communication error H
Regular communication time-out
16
Panel-related error 
Lamp failure
1A
Other error 2 
Monitor temperature failure
1D
Power supply error 1 
PS_ON(AC_DET) failure
1E
Power supply error 2 
D_POW(DET_12V) failure
1F
Power supply error 3 
D_POW(DET_D3V3) failure
21
Power supply error 5 
Panel power failure
23
Other error 3 
Error standby request from the main CPU
Error type
Power LED operation (1 cycle)
Note: Pins are monitor microprocessor pins (IC2002).
Inverter/Lamp failure
Red flashes once
H: Red On
L: Off
Refer to “Inverter/Lamp failure details”. OPC_LED flashes by 
pressing the [MENU] key on the remote control.
Power failure
Red flashes twice
H: Red On
L: Off
Refer to “Power failure details”. OPC_LED flashes by pressing the 
[MENU] key on the remote control.
Communication 
failure with main
CPU
Green flashes once
H: Green On
L: Off
Refer to “Communication failure details”. OPC_LED flashes by 
pressing [MENU] key on the remote control.
Communication line failure or main CPU communication failure.
Others
Green flashes twice
H: Green On
L: Off
Refer to “Other failure details”. OPC_LED flashes by pressing the 
[MENU] key on the remote control.
Error type
OPC (preset) LED operation (1 cycle)
Note: Pins are monitor microprocessor pins unless otherwise 
specified (IC2002).
Lamp failure
Flashes once
H: On
L: Off
ERR_PNL(40pin): Abnormal L. Confirmed after 5 consecutive 
detections at 1 second intervals (detected only when the backlight 
is on).
Note that after five detection counts, the lamp cannot be activated 
except in the monitoring process. (For the first time, only the 
inverter is reset, and error OFF is not activated.)
Accumulated counts are cleared to 0 when the setting in the 
adjustment process is made, when AC_ON is performed with 
[CH_DOWN] and [VOL_UP] on the unit down or after continuous 
illumination for 3 minutes.