DOWNLOAD Sharp LC-32GD8EA Service Manual ↓ Size: 2.36 MB | Pages: 22 in PDF or view online for FREE

Model
LC-32GD8EA
Pages
22
Size
2.36 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD / LC32GD8EA Supplement based on the LC32GD8E
File
lc-32gd8ea.pdf
Date

Sharp LC-32GD8EA Service Manual ▷ View online

 
DIFFERENCES FROM BASE MODEL
LIST OF CHANGED PARTS ...............................i
SAFETY PRECAUTION
IMPORTANT SERVICE SAFETY PRE-
CAUTION ...........................................................ii
PRECAUTIONS FOR USING LEAD-FREE 
SOLDER ........................................................... iii
CHAPTER 1. SPECIFICATIONS
[1] SPECIFICATIONS ......................................... 1-1
CHAPTER 2. DIMENSIONS
[1] DIMENSIONS ................................................ 2-1
CHAPTER 3. SCHEMATIC DIAGRAM
[1]  DESCRIPTION OF SCHEMATIC DIA-
GRAM ............................................................ 3-1
[2] MAIN 
Unit....................................................... 3-2
Parts Guide
SERVICE MANUAL
Parts marked with "
" are important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the
safety and performance of the set.
TopPage
CONTENTS
LC-32GD8EA/RUA, LC-32BT8EA/RUA
LC-32GD8EA/RUA
LC-32BT8EA/RUA
No. SY6Z3LC32D8EA
MODELS
LCD COLOUR TELEVISION
In the interests of user-safety (Required by safety regulations in some countries) the set shouldA
be restored to its original condition and only parts identical to those specified should be used.
OUTLINE
This model is based on the LC-32GD8E, LC-32BT8E and is changed some parts. This Service Manual covers the
modifications alone. For the other points, refer to the LC-32/37GD8E/RU, LC-32/37BT8E/RU Service Manual.
LC-32GD8EA/RUA, LC-32BT8EA/RUA
 i
LC-32GD8EA/RUA, LC-32BT8EA/RUA
Service Manual
 
DIFFERENCES FROM BASE MODEL
LIST OF CHANGED PARTS
Ref. No.
Description
LC-32GD8E
LC-32GD8EA/RUA, LC-32BT8EA/RUA
Note
PWB ASSEMBLIES
AV Unit
DUNTKD604FM10
POWER Unit
DUNTKD605FM14
OPERATION Unit
DUNTKD606FMV0
R/C, LED Unit
DUNTKD607FMV0
DIGITAL TUNER Unit
CKITKD609FM01
DIGITAL Unit
DUNTKD628FM01
MAIN Unit
DUNTKD890FM06
DUNTKD890FM28
Some parts changed
MAIN Unit
C1747
Capacitor
VCCCCY1HH101JY
Add
C1748
Capacitor
VCCCCY1HH101JY
Add
C1749
Capacitor
VCKYCY1HB221KY
Add
C1750
Capacitor
VCCCCY1HH101JY
Add
C1751
Capacitor
VCCCCY1HH101JY
Add
C1752
Capacitor
VCCCCY1HH101JY
Add
IC1905
IC
VHISII9023+-1Q
VHISII9021+-1Q  or  VHISII9023+-1Q
or use
P1701
Plug
QPLGNA342WJZZY
Add
P2305
Plug
QPLGNA522WJQZY
QPLGNA493WJZZY
Change
R1715
Resistor
VRS-CY1JF470JY
Add
R1717
Resistor
VRS-CY1JF000JY
VRS-CY1JF470JY
Change
R1718
Resistor
VRS-CY1JF470JY
Add
R1730
Resistor
VRS-CY1JF470JY
Add
R1731
Resistor
VRS-CY1JF102JY
Add
R1736
Resistor
VRS-CY1JF102JY
Add
R1752
Resistor
VRS-CY1JF470JY
Delete
R1773
Resistor
VRS-CY1JF000JY
Delete
R1774
Resistor
VRS-CY1JF470JY
Delete
R1775
Resistor
VRS-CY1JF103JY
Delete
R2303
Resistor
VRS-CY1JF000JY
Delete
CABINET AND MECHANICAL PARTS
    Please refer to a Parts list.
PACKING PARTS AND ACCESSORIES
    Please refer to a Parts list.
LC-32GD8EA/RUA, LC-32BT8EA/RUA
ii
LC-32GD8EA/RUA, LC-32BT8EA/RUA
Service Manual
 
SAFETY PRECAUTION
IMPORTANT SERVICE SAFETY PRECAUTION
„
WARNING
1. For continued safety, no modification of any circuit should be
attempted.
2. Disconnect AC power before servicing.
„
BEFORE RETURNING THE RECEIVER (Fire &
Shock Hazard)
Before returning the receiver to the user, perform the following
safety checks:
3. Inspect all lead dress to make certain that leads are not pinched,
and check that hardware is not lodged between the chassis and
other metal parts in the receiver.
4. Inspect all protective devices such as non-metallic control knobs,
insulation materials, cabinet backs, adjustment and compartment
covers or shields, isolation resistor-capacitor networks, mechanical
insulators, etc.
5. To be sure that no shock hazard exists, check for leakage current in
the following manner.
• Plug the AC cord directly into a 220~240 volt AC outlet. (Do not use
an isolation transformer for this test).
• Using two clip leads, connect a 1.5k ohm, 10 watt resistor paral-
leled by a 0.15
µF capacitor in series with all exposed metal cabinet
parts and a known earth ground, such as electrical conduit or elec-
trical ground connected to an earth ground.
• A true RMS reading multimeter should be used for this test, espe-
cially where the equipment uses a switch mode power supply
which may result in very non-sinusoidal leakage current.
• Connect the resistor connection to all exposed metal parts having a
return to the chassis (antenna, metal cabinet, screw heads, knobs
and control shafts, escutcheon, etc.) and measure the AC voltage
drop across the resistor.
All checks must be repeated with the AC cord plug connection
reversed. (If necessary, a nonpolarized adaptor plug must be used
only for the purpose of completing these checks.)
Any reading of 1.05 peak (this corresponds to 0.7 mA. peak AC.) or
more is excessive and indicates a potential shock hazard which
must be corrected before returning the monitor to the owner.
///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
SAFETY NOTICE
Many electrical and mechanical parts in LCD colour television have
special safety-related characteristics.
These characteristics are often not evident from visual inspection, nor
can protection afforded by them be necessarily increased by using
replacement components rated for higher voltage, wattage, etc.
Replacement parts which have these special safety characteristics are
identified in this manual; electrical components having such features
are identified by "
" and shaded areas in the Replacement Parts List
and Schematic Diagrams.
For continued protection, replacement parts must be identical to those
used in the original circuit.
The use of a substitute replacement parts which do not have the same
safety characteristics as the factory recommended replacement parts
shown in this service manual, may create shock, fire or other hazards.
///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
Service work should be performed only by qualified service technicians who are thoroughly familiar with all safety checks and the 
servicing guidelines which follow: 
CAUTION: FOR CONTINUED PROTECTION
AGAINST A RISK OF FIRE REPLACE ONLY WITH
SAME TYPE FUSE.
F701 (4A / AC250V)
DVM
AC SCALE
1.5k ohm
10W
TO EXPOSED
METAL PARTS
CONNECT TO
KNOWN EARTH
GROUND
0.15
µF
TEST PROBE
LC-32GD8EA/RUA, LC-32BT8EA/RUA
 iii
PRECAUTIONS FOR USING LEAD-FREE SOLDER
„
Employing lead-free solder
• “ALL PWBs” of this model employs lead-free solder. The LF symbol indicates lead-free solder, and is attached on the PWBs and service manuals.
The alphabetical character following LF shows the type of lead-free solder. 
Example:
• For the Inverter PWB Units the type used in nickel, so they are marked as LFn. 
„
Using lead-free wire solder
• When fixing the PWB soldered with the lead-free solder, apply lead-free wire solder. Repairing with conventional lead wire solder may cause dam-
age or accident due to cracks.
As the melting point of lead-free solder (Sn-Ag-Cu) is higher than the lead wire solder by 40 
°C, we recommend you to use a dedicated soldering
bit, if you are not familiar with how to obtain lead-free wire solder or soldering bit, contact our service station or service branch in your area.
„
Soldering
• As the melting point of lead-free solder (Sn-Ag-Cu) is about 220 
°C which is higher than the conventional lead solder by 40 °C, and as it has poor
solder wettability, you may be apt to keep the soldering bit in contact with the PWB for extended period of time. However, Since the land may be
peeled off or the maximum heat-resistance temperature of parts may be exceeded, remove the bit from the PWB as soon as you confirm the
steady soldering condition.
Lead-free solder contains more tin, and the end of the soldering bit may be easily corroded. Make sure to turn on and off the power of the bit as
required.
If a different type of solder stays on the tip of the soldering bit, it is alloyed with lead-free solder. Clean the bit after every use of it.
When the tip of the soldering bit is blackened during use, file it with steel wool or fine sandpaper.
• Be careful when replacing parts with polarity indication on the PWB silk.
Lead-free wire solder for servicing
PARTS CODE
PRICE 
RANK
PART 
DELIVERY
DESCRIPTION
ZHNDAi123250E
BL
J
φ0.3mm 250g (1roll)
ZHNDAi126500E
BK
J
φ0.6mm 500g (1roll)
ZHNDAi12801KE
BM
J
φ1.0mm 1kg (1roll)
Indicates lead-free solder of tin, silver and copper.
Indicates lead-free solder of tin, silver and nickel.
Page of 22
Display

Sharp LC-32GD8EA Service Manual ▷ Download

  • DOWNLOAD Sharp LC-32GD8EA Service Manual ↓ Size: 2.36 MB | Pages: 22 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp LC-32GD8EA in PDF for free, which will help you to disassemble, recover, fix and repair Sharp LC-32GD8EA LCD. Information contained in Sharp LC-32GD8EA Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.