SERVICE MANUAL
LCD COLOUR
TELEVISION (Display)
MODEL
In the interests of user-safety (Required by safety regulations in some countries) the set should be restored
to its original condition and only parts identical to those specified should be used.
SHARP
CONTENTS
CORPORATION
NOTE ON ELECTROSTATICAL SHIELDING .....................................................................................................2
SAFETY WARNINGS / REGULATIONS .............................................................................................................2
PRECAUTIONS FOR USING LEAD-FREE SOLDER .........................................................................................3
REAR PANEL REMOVAL ....................................................................................................................................4
WIRING DIAGRAM L2650 ..................................................................................................................................6
ENTER SERVICE MODE ....................................................................................................................................8
OPTION BYTES TABLE WITH SERVICE RELEVANT OPTION BITS .............................................................15
SERVICE MENU L2650 (LCD) ..........................................................................................................................21
SOFTWARE LOADING .....................................................................................................................................22
COMPONENTS CHART ...................................................................................................................................24
TECHNICAL SPECIFICATIONS ........................................................................................................................25
TROUBLESHOOTING FOR LCD-CONTROLLER AND MICOM-BOARD ........................................................26
APPENDIX ........................................................................................................................................................30
SPARE PARTS LIST .........................................................................................................................................73
230-90432994
LC32GD7E
LC32GD7E
2
Note on electrostatic shielding
 
1. Electrostatically shielded MOS workstations 
Components sensitive to electrostatic discharge 
must be handled at workstation with electrostatic 
shielding. An electrostatically shielded MOS work-
station is fi tted with discharge resistor which earth 
all conductive materials, including the technician 
working there. Dielectrics are discharged by air 
ionisation. The use of soldering irons and meas-
uring equipment at shielded workstation is only 
possible in conjunction with isolating transformer 
in each of the devices used. Measuring equip-
ment chassis are also earthed with discharge re-
sistors. 
2. Shielded packaging using conductive 
 materials 
To protect against electrostatic charges, electri-
cally conductive plastics are used for packaging 
and transport purposes. Conductive plastics are 
available in the form of transparent protective 
bags, foam plastic, fi lm sheeting or containers. 
Sensitive components requiring the use of pro-
tective packaging must only be packed and un-
packed at shielded workstations.
Safety warnings/regulations 
1. The repair, modifi cation and testing of mains-op-
erated electronic devices and their accessories 
must only be performed by qualifi ed persons. 
2. It is necessary to follow the regulations and safety 
warnings to VDE 0701, part 200, as well as the 
regulations and safety warnings applicable in the 
country concerned. 
3. VDE 0701, Part 2, contains regulations on the re-
pair, modifi cation and testing of mains-operated 
electronic devices and their accessories. 
4. Before delivery, the device and the connecting 
leads (including any protective earth conductor 
fi tted) must undergo visual inspection, and the 
insulation resistance and the equivalent leak-
age current must be measured according to VDE 
0701, part 200. The low-resistance continuity of 
the protective earth conductor must be verifi ed by 
measurement to VDE regulation 0701, part 1. 
5. The regulations of the country concerned must 
also be observed. 
6. Only genuine parts must be used for replacing 
components marked with the symbol
 
 . 
3
Precautions for using lead-free solder
1. Employing lead-free solder
„LCD CONT PWB“,“TMDS RX PWB“,“KEY PWB“,“R/C LED PWB“,“MOTOR PWB“,“INV PWB“,“POWER 
PWB“of this model employs lead-free solder. The LF symbol indicates lead-free solder, and is attached on 
the PWBs and service manuals. The alphabetical character following LF shows the type of lead-free solder.  
Example:
 
 
 
 
 
 
 
Indicates lead-free solder of tin, silver and copper.
2. Using lead-free wire solder
When fi xing the PWB soldered with the lead-free solder, apply lead-free wire solder. Repairing with conven-
tional lead wire solder may cause damage or accident due to cracks.
As the melting point of lead-free solder (Sn-Ag-Cu) is higher than the lead wire solder by 40ºC, we recom-
mend you to use a dedicated soldering bit, if you are not familiar with how to obtain lead-free wire solder or 
sodening bit, contact our service station or service ranch in your area.
3. Soldering
As the melting point of lead-free solder (Sn-Ag-Cu) is about 220°C which is higher than the conventional 
lead solder by 40°C, and as it has poor solder wettabillty, you may be apt to keep the soldering bit in contact 
with the PWB for extended period of time. However, Since the land may be peeled off or the maximum heat-
resistance temperature of parts may be excoeded, remove the bit from the PWB as soon as you conurm the 
steady soldering condition.
Lead-free solder contains more tin, and the end of the soldering bit may be easily corroded. Make sure to 
turn on and off the power of the bit as required. if a different type of solder stays on the tip of the soldering 
bit, it is alloyed with lead-free solder. Clean the bit after every use of it.
When the tip of the soldering bit is blackened during use, fi le it with steel wool or fi ne sandpaper.
Lead-free wire solder for servicing
Be careful when replacing parts with polarity indication on the PWB silk.
L
F a
Pb
Part No.
Ë
Description
Code
ZHNDAi123250E
J
φ 
0.3mm 250g(1roll)
BL
ZHNDAi126500E
J
φ 
0.6mm 500g(1roll)
BK
ZHNDAi12801KE
J
φ 
1.0mm 1kg(1roll)
BM
4
Rear panel removal
1. Place the set on a clean and soft base.
2. Open the 4 screws (fi g. 1).
3. Open the 18 screws (fi g. 2).
4. Mount stand for serviceposition. 
Fig. 1
Fig. 2
Page of 106
Display

Sharp LC-32GD7E (serv.man2) Service Manual ▷ Download

  • DOWNLOAD Sharp LC-32GD7E (serv.man2) Service Manual ↓ Size: 12.23 MB | Pages: 106 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp LC-32GD7E (serv.man2) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp LC-32GD7E (serv.man2) LCD. Information contained in Sharp LC-32GD7E (serv.man2) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.