Sharp LC-32FH510E (serv.man7) Service Manual ▷ View online
23
7. White Balance Adjustment
Condition: AV MODE= Dynamic (backlight at max.).
• Adjustments reference device: Minolta CA-210
• Adjustments target: x=0.272, y=0.277
High: adjustments spec ±0.001, inspection spec: ±0.002
Low: adjustments spec ±0.002, inspection spec: ±0.004
• Adjustments reference device: Minolta CA-210
• Adjustments target: x=0.272, y=0.277
High: adjustments spec ±0.001, inspection spec: ±0.002
Low: adjustments spec ±0.002, inspection spec: ±0.004
1. Press “▼” until selecting “GAMMA” option.
2. Press “OK”.
3. “GAMMA” menu appears.
4. Press “▼” until selecting “MGAMMA RESET”.
5. Press “►”, to restore default values.
6. “MGAMMA RESET SUCCESS” appears.
7. Press “P+” to increase one page.
8. Press “1”, appears “Internal Adjustments Pattern 1”.
9. Hold the default value for “MGAMMA G1”.
(Note: next, try to get the (x, y) adjustments target,
changing “MGAMMA R1” and “MGAMMA B1” as follow).
10. Press “▼” until selecting “MGAMMA R1”.
11. Press “◄ ►” until you obtain the desired value.
12. Press “MENU” to return to previous menu.
13. Press “▼” until selecting “MGAMMA B1”.
14. Press “◄ ►” until you obtain the desired value.
15. Press “MENU” to return to previous menu.
2. Press “OK”.
3. “GAMMA” menu appears.
4. Press “▼” until selecting “MGAMMA RESET”.
5. Press “►”, to restore default values.
6. “MGAMMA RESET SUCCESS” appears.
7. Press “P+” to increase one page.
8. Press “1”, appears “Internal Adjustments Pattern 1”.
9. Hold the default value for “MGAMMA G1”.
(Note: next, try to get the (x, y) adjustments target,
changing “MGAMMA R1” and “MGAMMA B1” as follow).
10. Press “▼” until selecting “MGAMMA R1”.
11. Press “◄ ►” until you obtain the desired value.
12. Press “MENU” to return to previous menu.
13. Press “▼” until selecting “MGAMMA B1”.
14. Press “◄ ►” until you obtain the desired value.
15. Press “MENU” to return to previous menu.
(Note: In case of not being possible to achieve the desired
(x, y) target, try to get it by changing also the “MGAMMA G1”)
(x, y) target, try to get it by changing also the “MGAMMA G1”)
16. Press “2”, appears “Internal Adjustments Pattern 2”.
17. Repeat from step 9 to 15 for the “MGAMMA R2” and “MGAMMA B2”.
18. Press “3”, appears “Internal Adjustments Pattern 3”.
19. Repeat from step 9 to 15 for the “MGAMMA R3” and “MGAMMA B3”.
20. Press “4”, appears “Internal Adjustments Pattern 4”.
21. Repeat from step 9 to 15 for the “MGAMMA R4” and “MGAMMA B4”.
22. Press “5”, appears “Internal Adjustments Pattern 5”.
23. Repeat from step 9 to 15 for the “MGAMMA R5” and “MGAMMA B5”.
24. Press “6”, appears “Internal Adjustments Pattern 6”.
25. Repeat from step 9 to 15 for the “MGAMMA R6” and “MGAMMA B6”.
26. Press “▼” until selecting “MGAMMA WRITE”.
27. Press “►”, to save the new values.
28. “MGAMMA WRITE SUCCESS” appears.
17. Repeat from step 9 to 15 for the “MGAMMA R2” and “MGAMMA B2”.
18. Press “3”, appears “Internal Adjustments Pattern 3”.
19. Repeat from step 9 to 15 for the “MGAMMA R3” and “MGAMMA B3”.
20. Press “4”, appears “Internal Adjustments Pattern 4”.
21. Repeat from step 9 to 15 for the “MGAMMA R4” and “MGAMMA B4”.
22. Press “5”, appears “Internal Adjustments Pattern 5”.
23. Repeat from step 9 to 15 for the “MGAMMA R5” and “MGAMMA B5”.
24. Press “6”, appears “Internal Adjustments Pattern 6”.
25. Repeat from step 9 to 15 for the “MGAMMA R6” and “MGAMMA B6”.
26. Press “▼” until selecting “MGAMMA WRITE”.
27. Press “►”, to save the new values.
28. “MGAMMA WRITE SUCCESS” appears.
NOTE:
For activating the W/B fl ag, only is necessary to send the order MGAMMA WRITE. After this action, the “W” W/B
fl ag will change to “1”.
For activating the W/B fl ag, only is necessary to send the order MGAMMA WRITE. After this action, the “W” W/B
fl ag will change to “1”.
LC-32FH500
LC-32FH510
LC-32FH510
24
8. Initialization to factory setting
Caution: When the factory settings have been made, all user setting data, including the channel settings, are initialized.
(The adjustments done in the adjustment process mode are not initialized.) Keep this in mind when initializing these settings.
(The adjustments done in the adjustment process mode are not initialized.) Keep this in mind when initializing these settings.
1. Enter in Service mode.
2. Press “▼” or “▲” key until selecting INIT.
3. Press OK key.
4. INIT menu appears and “Factory init” option is selected.
5. Press “◄” or “►” until selecting the option desired (EURO/RUSSIA/SWEDEN/UK/EAST EUROPE).
6. Press OK key and initialization starts.
7. OK, EURO message appears for EURO option when the setting is complete.
2. Press “▼” or “▲” key until selecting INIT.
3. Press OK key.
4. INIT menu appears and “Factory init” option is selected.
5. Press “◄” or “►” until selecting the option desired (EURO/RUSSIA/SWEDEN/UK/EAST EUROPE).
6. Press OK key and initialization starts.
7. OK, EURO message appears for EURO option when the setting is complete.
OK, RUSSIA message appears for RUSSIA option when the setting is complete.
OK, SWEDEN message appears for SWEDEN option when the setting is complete.
OK, UK message appears for UK option when the setting is complete.
OK, EAST EUROPE message appears for EAST EUROPE option when the setting is complete.
Note: Never turn the power off during initialization.
OK, SWEDEN message appears for SWEDEN option when the setting is complete.
OK, UK message appears for UK option when the setting is complete.
OK, EAST EUROPE message appears for EAST EUROPE option when the setting is complete.
Note: Never turn the power off during initialization.
To exit the adjustment process mode, unplug the AC power cord from the outlet to forcibly turn off the power.
The following settings will be back to their factory ones.
• User settings
• Channel data (e.g. broadcast frequencies)
• Maker option setting
• Password data
• Channel data (e.g. broadcast frequencies)
• Maker option setting
• Password data
LC-32FH500
LC-32FH510
LC-32FH510
25
9. Lamp error detection
1. Function description
This LCD colour television has a function (lamp error detection) to be turned OFF the TV set automatically for
safety criteria when the lamp or lamp circuit is abnormal.
If the lamp or lamp circuit is abnormal, or some other errors happen, and the lamp error detection is executed, the
following occurs:
safety criteria when the lamp or lamp circuit is abnormal.
If the lamp or lamp circuit is abnormal, or some other errors happen, and the lamp error detection is executed, the
following occurs:
a. The TV set is turned OFF automatically 20 seconds after it is turned ON by the user.
(The power LED on the front side of TV turns from green to red)
b. If the situation “a.” happens 5 times sequentially, it becomes impossible to turn on the power.
(The power LED turns from green to red and keeps blinking in red).
LED Flashing timing
260 ms
1 s
Red → 260 ms
Off → 1s
2. Countermeasures
a. Checking with [L Error Check Off]. Repair the problem that produces the LAMP ERROR. The TV remains
with power LED blinking until K mode is forced by local keyboard, in order to disable the LAMP ERROR detec-
tion. To disable the LAMP ERROR feature is necessary enter in K mode by pressing “VOL DOWN” and “b”
keys at same time when the AC cord is plugged in.
with power LED blinking until K mode is forced by local keyboard, in order to disable the LAMP ERROR detec-
tion. To disable the LAMP ERROR feature is necessary enter in K mode by pressing “VOL DOWN” and “b”
keys at same time when the AC cord is plugged in.
b. Resetting the LAMP ERROR counter. After the lamp and lamp circuit are found out of trouble, the LAMP
ERROR counter should be reset. If a LAMP ERROR is detected fi ve consecutive times, the power cannot be
turned on.
ERROR counter should be reset. If a LAMP ERROR is detected fi ve consecutive times, the power cannot be
turned on.
Method 1: Using the cursor (UP/DOWN) key, move to the cursor to [L Error Reset] on Line 6 of ETC Menu Fig
4. With the cursor (LEFT/RIGHT) keys reset the value to “0”.
Method 2: In the case the TV is not blocked (less than 5 consecutive errors), switch on the Set. After 30 minutes
working, the LAMP ERROR counter will be reset automatically.
LC-32FH500
LC-32FH510
LC-32FH510
26
10. Public Mode (Hotel mode)
1. How to Enter in the Public Mode (Hotel Mode).
There are three following ways to display the Public Mode setting screen.
Method 1:
Turn on the power and enter in the Service mode as usual and select line 8 [PUBLIC MODE].
Turn on the power and enter in the Service mode as usual and select line 8 [PUBLIC MODE].
Method 2:
Unplug the AC power cord.
While pressing “VOL+” and “b” keys at the same time, plug the AC power cord.
Then, when you are asked for the password, enter “0027”.
After this sequence the TV will turn on showing the Public Mode setting screen as it is shown in Fig. 5.
In another case, the screen is erased, and it operates in the ordinary mode.
Unplug the AC power cord.
While pressing “VOL+” and “b” keys at the same time, plug the AC power cord.
Then, when you are asked for the password, enter “0027”.
After this sequence the TV will turn on showing the Public Mode setting screen as it is shown in Fig. 5.
In another case, the screen is erased, and it operates in the ordinary mode.
Method 3:
By special R/C code: RC table LCD, SYS CORD: 0x78, RC DATA: (HEX) 0xC7, (DEC) 199.
Then, when you are asked for the password, enter “0027”.
After this sequence the TV will turn on showing the Public Mode setting screen as it is shown in Fig. 5.
By special R/C code: RC table LCD, SYS CORD: 0x78, RC DATA: (HEX) 0xC7, (DEC) 199.
Then, when you are asked for the password, enter “0027”.
After this sequence the TV will turn on showing the Public Mode setting screen as it is shown in Fig. 5.
Is possible to select each item of function by pressing cursor UP/DOWN keys on the remote control or CH (UP/
DOWN) keys on the LCD TV.
DOWN) keys on the LCD TV.
The setting position of each item of functions is made by pressing cursor RIGHT/LEFT keys on the remote control
or VOL (+) / (-) keys on the LCD TV.
or VOL (+) / (-) keys on the LCD TV.
Set to ON the HOTEL MODE function to active it.
Select EXECUTE position after you set all function, and press cursor RIGHT/LEFT keys on the remote control or
VOL (+) / (-) keys on the LCD TV for confi rmation.
VOL (+) / (-) keys on the LCD TV for confi rmation.
Unplug and plug the AC power cord to take effect all the changes.
2. Public Mode Settings.
1. POWER ON FIXED [VARIABLE FIXED]
When it is set to “FIXED” the TV is impossible to be switch off by Main Switch or Remote Control.
2. MAXIMUM VOLUME [0 60]
Is possible to set the maximum volume at limited level.
3. VOLUME FIXED [VARIABLE FIXED]
Is possible to fi x the sound volume at limited level.
When “FIXED” is selected the sound volume before limited is fi xed.
When “FIXED” is selected the sound volume before limited is fi xed.
4. VOLUME FIXED LEVEL [0 60]
If “FIXED” has been selected, is possible to set a fi xed volume at the level that is chosen.
If “FIXED” has been selected, is possible to set a fi xed volume at the level that is chosen.
5. RC BUTTON [RESPOND NO RESPOND]
If “NO RESPOND” is selected, the remote control keys are inoperative.
6. PANEL BUTTON [RESPOND NO RESPOND]
If “NO RESPOND” has been selected, the set’s keys remain deactivated (Except POWER key).
7. MENU BUTTON [RESPOND NO RESPOND]
If “NO RESPOND” has been selected, “MENU” key, of remote control, is inoperative.
LC-32FH500
LC-32FH510
LC-32FH510
Click on the first or last page to see other LC-32FH510E (serv.man7) service manuals if exist.