Sharp LC-32D12EA Handy Guide ▷ View online
Pin Assignments
Version 1.0
Issue 07/2012
Issue 07/2012
9
SHARP ELECTRONICS (UK) LTD
CE TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
HDMI
PIN# Signal
PIN# Signal
PIN# Signal
1
TMDS Data 2+
8
TMDS Data 0 Shield
15
DDC Clock
2
TMDS Data 2 Shield
9
TMDS Data 0
16
DDC Data
3
TMDS Data 2
10
TMDS Clock+
17
Ground
4
TMDS Data 1+
11
TMDS Clock Shield
18
+5V Power
5
TMDS Data 1 Shield
12
TMDS Clock
19
Hot Plug Detect
6
TMDS Data 1
13
CEC
20
SHELL
7
TMDS Data 0+
14
No Connect
Maintenance Procedure
Version 1.0
Issue 07/2012
Issue 07/2012
10
SHARP ELECTRONICS (UK) LTD
CE TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Cleaning the LCD
•
Ensure you unplug the power cord before cleaning the LCD.
•
The cabinet as well as the operation panel is made of plastic.
Avoid using benzene or thinner, as these can damage the finish
on the cabinet.
•
Do not use volatile agents such as insecticides on the LCD. Do
not attach rubber or plastic items on the LCD for long periods of
time. The effects of some of the agents in the plastic may cause
damage to the quality or finish of the LCD.
•
Wipe off dirt gently with a soft flannel cloth.
•
When the dirt is hard to remove, soak a cloth in a neutral
detergent diluted with water, wring the cloth well and then wipe the LCD.
Strong cleaning detergents may discolour, warp or damage the coating on the LCD.
Ensure you test on a small, inconspicuous area on the LCD before using.
Cleaning the intake vents
•
Use a vacuum cleaner to clean dust from the exhaust vent and the intake vent.
Firmware Upgrade Procedure
Version 1.0
Issue 07/2012
Issue 07/2012
11
SHARP ELECTRONICS (UK) LTD
CE TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Firmware Upgrade Procedure
Part Number
Description
Price Rank
Commercially Available
USB Pen Drive 32MB - 1GB
N/A
1.
Please copy the files to USB (root).
•
mb60_en.bin
• mboot.bin
• usb_auto_update.txt
2.
Turn power to OFF by mechanical switch (rocker switch) or removing AC plug.
And plug the USB to TV
3.
Keep pressing OK key from remote controller and then turn the TV power to ON
(by mechanical switch or by inserting the AC plug) and keep OK key pressed until
the standby LED blinks rapidly(rapid blinking is faster than normal blinking)
4.
When the LED is started to blink rapidly, you can release the OK key. Please wait
approximately for 1-2 minutes
5.
When the blinks of led is stopped, TV opens automatically with the new SW.
Unit Rest Procedures
Version 1.0
Issue 07/2012
Issue 07/2012
12
SHARP ELECTRONICS (UK) LTD
CE TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Entering and exiting the adjustment process mode
1. Turn on the TV
2. Press “MENU” then press “4725”
The following screen will appear:
Select “Diagnostics”, then highlight “Factory Reset” and press “OK”:
Click on the first or last page to see other LC-32D12EA service manuals if exist.