7
LC-32D12E(A)
LC-40F22E(A)
LC-20B5E
TO EXPOSED
METAL PARTS
CONNECT TO
KNOWN EARTH
GROUND
DVM
AC SCALE
1.5k ohm
10W
0.15 µF
TEST PROBE
SAFETY NOTICE
Many electrical and mechanical parts in LCD television have special safety-related characteristics.
These characteristics are often not evident from visual inspection, nor can protection afforded by them be necessarily 
increased by using replacement components rated for higher voltage, wattage, etc.
Replacement parts which have these special safety characteristics are identified in this manual; electrical components 
having such features are identified by    “    “.
For continued protection, replacement parts must be identical to those used in the original circuit.
The use of a substitute replacement parts which do not have the same safety characteristics as the factory recommended 
replacement parts shown in this service manual, may create shock, fire or other hazards.
IMPORTANT SERVICE SAFETY PRECAUTION
Service work should be performed only by qualified service technicians who are thoroughly familiar with all
safety checks and the servicing guidelines which follow:
WARNING
1. For continued safety, no modification of any circuit should be attempted.
2. Disconnect AC power before servicing.
BEFORE RETURNING THE RECEIVER (Fire & Shock Hazard)
Before returning the receiver to the user, perform the following safety checks:
1. Inspect all lead dress to make certain that leads are not pinched, and check that hardware is not lodged between the 
chassis and other metal parts in the receiver.
2. Inspect all protective devices such as non-metallic control knobs, insulation materials, cabinet backs, adjustment and 
compartment covers or shields, isolation resistor-capacitor networks, mechanical insulators, etc.
3. To be sure that no shock hazard exists, check for leakage current in the following manner. 
• Plug the AC cord directly into a 220~240 volt AC outlet. (Do not use an isolation transformer for this test).
•Using two clip leads, connect a 1.5k ohm, 10 watt resistor paralleled by a 0.15µF capacitor in series with all exposed metal 
cabinet parts and a known earth ground, such as electrical conduit or electrical ground connected to an earth ground.
•A true RMS reading multimeter should be used for this test, especially where the equipment uses a switch mode 
power supply which may result in very non-sinusoidal leakage current.
•Connect the resistor connection to all exposed metal parts having a return to the chassis (antenna, metal cabinet, 
screw heads, knobs and control shafts, escutcheon, etc.) and measure the AC voltage drop across the resistor.
All checks must be repeated with the AC cord plug connection reversed. (If necessary, a nonpolarized adaptor plug must 
be used only for the purpose of completing these checks.)
Any reading of 1.05V peak (this corresponds to 0.7 mA. peak AC.) or more is excessive and indicates a potential shock 
hazard which must be corrected before returning the monitor to the owner.
!
  CAUTION: FOR CONTINUED PROTECTION AGAINST A RISK OF
  FIRE REPLACE ONLY WITH SAME TYPE  
 
F800, F801 (T 3.15A  250V  RADIAL)
8
LC-32D12E(A)
LC-40F22E(A)
e:
Indicates lead-free solder of tin, silver and copper.
L
F a
PRECAUTIONS FOR USING LEAD-FREE SOLDER
1 Employing lead-free solder
“ALL  PWB” of this model employs lead-free solder. The LF symbol indicates lead-free solder, and is attached on the 
PWBs and service manuals. The alphabetical character following LF shows the type of lead-free solder.
Example:
2 Using lead-free wire solder
When fixing the PWB soldered with the lead-free solder, apply lead-free wire solder. Repairing with conventional lead 
wire solder may cause damage or accident due to cracks.
As the melting point of lead-free solder (Sn-Ag-Cu) is higher than the lead wire solder by 40°C, we recommend you to 
use a dedicated soldering bit, if you are not familiar with how to obtain lead-free wire solder or soldering bit, contact our 
service station or service branch in your area.
3 Soldering
As the melting point of lead-free solder (Sn-Ag-Cu) is about 220°C which is higher than the conventional lead solder by 
40°C, and as it has poor solder wettability, you may be apt to keep the soldering bit in contact with the PWB for extended 
period of time. However, Since the land may be peeled off or the maximum heat-resistance temperature of parts may be 
exceeded, remove the bit from the PWB as soon as you confirm the steady soldering condition.
Lead-free solder contains more tin, and the end of the soldering bit may be easily corroded. Make sure to turn on and 
off the power of the bit as required.
If a different type of solder stays on the tip of the soldering bit, it is alloyed with lead-free solder. Clean the bit after every 
use of it.
When the tip of the soldering bit is blackened during use, file it with steel wool or fine sandpaper.
Be careful when replacing parts with polarity indication on the PWB silk.
Lead-free wire solder for servicing.
Indicates lead-free solder of tin, silver and nickel.
L
F n
Sn-Ag-Ni
9
LC-32D12E(A)
LC-40F22E(A)
END OF LIFE DISPOSAL
English   - 38 -
End of life disposal
00_MB60_[GB]_1910UK_IDTV_PVR_NICKEL16_32883W_YPBPR_ROCKER_10075570_5019xxxx.indd   38
07.09.2011   15:46:29
10
LC-32D12E(A)
LC-40F22E(A)
OPERATION MANUAL
English   - 8 -
Remote Control Buttons
Standby
1.
Image size / Zooms videos (in Media Browser 
2.
video mode)
Sleep Timer
3.
Mono / Stereo - Dual I-II / Currrent Language (*) 
4.
(in DVB channels)
Favourite Mode Selection (in DVB channels)
5.
Numeric buttons
6.
Electronic programme guide (in DVB channels)
7.
No function
8.
Media Browser
9.
Navigation buttons (Up/Down/Left/Right)
10.
No function
11. 
Recordings Library
12.
Programme Down / Page up - Programme Up / 
13.
Page down
Mute
14.
Programme recording
15.
Pause (in Media Browser mode) / Timeshift 
16.
recording
Rapid reverse (in Media Browser mode)
17.
Play (in Media Browser mode)
18.
Red button
19.
Green button / List Schedule (in EPG) / Tag 
20.
/ Untag All (in favourite list) / Play-Slideshow 
(in Media Browser) / Loop-Shuffl e (in Media 
Browser)
Picture mode selection / Changes picture mode 
21.
(in Media Browser video mode) 
No function
22.
Teletext / Mix (in TXT mode)
23.
Subtitle on-off (in DVB channels)
24.
Previous programme
25.
AV / Source selection
26.
Menu on-off
27.
Okay (Confi rm) / Hold (in TXT mode) / Edit 
28.
Channel List
Exit / Return / Index page (in TXT mode)
29.
No function
30.
Info / Reveal (in TXT mode)
31.
Volume Up / Down
32.
No function
33.
No function
34.
Rapid advance (in Media Browser mode)
35.
SLEEP
SCREEN
PRESETS
LANG.
FAV
EPG
SWAP
SOURCE
C
DISP.
SEARCH
MODE
INFO
CH
V
Stop (in Media Browser mode)
36.
Blue button / Edit Channel List / Filter (In 
37.
Favourite List&EPG) 
Yellow button / Timeline Schedule (in EPG)
38.
00_MB60_[GB]_1910UK_IDTV_PVR_NICKEL16_32883W_YPBPR_ROCKER_10075570_5019xxxx.indd   8
07.09.2011   15:45:59
Page of 116
Display

Click on the first or last page to see other LC-32D12EA (serv.man2) service manuals if exist.