Precautions in handling the LCD panels
1. Work in a clean room (with humidities below 50%).
2. Be sure to wear an anti-static armband.
3. Handle the panels on an electroconductive mat.
4. Be careful not to fall, shake and shock the panels.
17. Remove the LCD panel unit fixing screws (4 pcs.).
18. Remove the ITO earth spring fixing screw (1 pc.).
19. Remove the reflection/deflection, prism, diffusion, ITO sheets and diffusion panel.
20. Remove the lamp fixing holder fixing screws (6 pcs.).
21. Detach the lamp unit-A/B.
22. Remove the reflection mirror fixing screws. (6 pcs.).
22
21
20
18
19
20
17
17
Back shield Panel
 (PSLDM4685CEFW)
Reflection Mirror
 (PMiR-0296CEZZ)
Lamp Fixing Holder
 (LHLDZ2176CEZZ)
Diffusion Panel
 (PCOVU0107CEZZ)
ITO Sheet
 (PSHEP0289CEZZ)
Prism Sheet
 (PSHEP0287CEZZ)
20" LCD Panel Unit
Reflection/Deflection Sheet
 (PSHEP0286CEZZ)
Diffusion Sheet
 (PSHEP0288CEZZ)
ITO Earth Spring
 (MSPRP1220CEFW)
Lamp Fixing Holder
 (LHLDZ2176CEZZ)
Lamp Unit-B
 (KLMP-A125CEZZ)
Lamp Unit-A
 (KLMP-A124CEZZ)
10
LC-20E1E
P6705
SC1201
SC1202
SC1202
P4004
P4004
SC1203
P3702
P2003
P6706
P6705
SC1203
SC2001
SC2001
SC3100
P1903
SC1602
P1903
SC1602
P6706
P3603
P3301
P3302
P3602
P3601
P3601
Inverter-A
PWB
Inverter-B
PWB
Wire holder
Main PWB
Tuner PWB
Main PWB
P3604
P3604
SC2002
7-2
Main unit
(Side B)
2
3
1
5 6
4
R/C, LED PWB
7-3
7-1
Tape
»
Precautions at the time of the side B(back) service of main unit.
1. Remove only SC2001 of the FFC for connection between Main unit(SC2001) and Tuner unit(SC3100), and con-
nect the extended cable (                  ) for service.
2. Remove only P3702 of the FFC for connection between Main unit(P3702) and Tuner unit(P1903), and connect the
extended cable (                   ) for service.
3. Remove only SC2002 of the FFC for connection between Main unit(SC2002) and Tuner unit(SC1602), and con-
nect the extended cable (                   ) for service.
4. Remove the FFC for connection between Main unit(SC1203) and LCD panel unit, and connect the extended cable
(                  ) for service.
5. Remove the FFC for connection between Main unit(SC1202) and LCD panel unit, and connect the extended cable
(                   ) for service.
6. Remove the FFC for connection between Main unit(SC1201) and LCD panel unit, and connect the extended cable
(                  ) for service.
7. Remove the R/C, LED unit.
7-1. Peel off the tape.
7-2. Remove a lead from a wire holder.
7-3. Remove the R/C, LED unit fixing screws(2 pcs.).
8. Remove the main unit fixing screws(3 pcs.), a substrate is reversed.
11
LC-20E1E
12
LC-20E1E
4. Initialization
When the microprocessor (IC2001) or the EEPROM (IC2004) has been replaced or when the EEPROM has been
initialized, readjust the each adjustments.
4-1. Connect the pins (81) and (82) of IC2001 (microprocessor) to GND, and turn on the power.
4-2. Select the model name to (E1E).
4-3. Select the inch size (20).
4-4. LED changes green from red after setting finish and about 15 seconds, initialization is completed, and it
becomes adjustment mode.
5. Adjustment
5-1. +B adjustment...Page 1 +B-ADJ
Adjust the voltage of the pin (13) of P2002 to 5.00 
±
0.02V.
Note: Since 5.0V is a reference voltage of all power voltage, adjust it precisely.
5-2. Counter-bias adjustment
Vary the "COM BIAS" setting on Page 2 of the adjustment process mode so that the contrast be sharpest
(black looks most sinking).
5-3. TAMP adjustment
1) Receive the upper left of 75% white half colour bar signal.
2) See if the “Y” reading on page 2 of the adjusment process mode is somewhere following. If not, make the
“PAL TAMP” adjustment to get the “Y” reading in the range of BB thru CA.
3) If the adjustment of “PAL TAMP” is executed, write its adjustment value to the “SECAM TAMP” manually.
(Screen of the page 2 of the adjustment processing menu OSD)
0
1
2
3
4
5
6
7
8
9
10
11 12 13
14 15 16
17 18 19
20 21 22
23 24 25 26
2
C
O
M
B
I
A
S
9
0
P
A
L
T
A
M
P
2
1
S
E
C
A
M
T
A
M
P
2
1
G
C
U
T
O
F
F
R
C
U
T
O
F
F
0
5
B
C
U
T
O
F
F
G
3
B
3
R
3
0
0
0
0
0
0
3
G
1
B
4
Y
0
0
0
0
B
5
T
A
M
P
H
T
A
M
P
L
 
 
 
 
 
C
A
B
B
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Y Data
(White 75%)
5-4. White balance adjustment
Adjust “RCUTOFF” and “BCUTOFF” on the page 2 of the adjustment processing so as to obtain the colour
of the same level as the standard set.
Note: For the adjustment processing of “RCUTOFF” and “BCUTOFF”, adjust them in the indication value
range of ... –9, –7, ... –1, +1, ... +7, +9.
When it becomes even-numbered value, side favor noise sometimes occurs in the monochrome signal of
the specific gradation.
Page of 62
Display