7
LC-20E1E
REMOVING OF MAJOR PARTS
1. Remove the table stand fixing screws (4 pcs.).
2. Remove the two terminal covers.
3. Remove the terminal section fixing screws (2 pcs.).
4. Remove the cabinet B fixing screws (10 pcs.).
5. Remove the cabinet B after opening from the direction of an arrow.
6. Peel off the tape. Remove the reinforcement angle fixing screws (4 pcs.).
7. Remove the top cover fixing screws (2 pcs.).
8. Remove the operation PWB fixing screws (2 pcs.).
9. Peel off the tape.
10. Detach the connector from each PWB.
3
4
4
4
2
2
5
1
Cabinet A
Cabinet B
Stand
Terminal 
Cover (S)
Terminal 
Cover (L)
P6705
P6705
SC1201
SC1202
SC1202
SC1202
P4004
P4004
P4004
SC1203
SC1203
P3702
P2003
P6706
P6706
P6705
SC1203
SC2001
SC2001
SC2001
SC3100
P1903
P1903
SC1602
SC1602
P1903
SC1602
P6706
P3603
P3301
P3302
P3602
0
0
0
0
0
0
0
0
0
0
0
0
0
6
P3601
P3601
P3601
7
8
Reinforcement
Angle
Tape
Inverter-A
PWB
Inverter-B
PWB
R/C, LED PWB
Operation PWB
Main PWB
Main PWB
Tuner PWB
Main PWB
6
Tape
9
0
P3604
P3604
P3604
SC2002
8
LC-20E1E
11. Remove the inverter-A PWB fixing screws (2 pcs.).
12. Remove the inverter-B PWB fixing screws (1 pc.).
13. Remove the main PWB fixing screws (3 pcs.).
14. Remove the 21-pin terminal fixing screw (2 pcs.).
15. Remove the tuner PWB fixing screws (3 pcs.) and detatch the chassis frame cover fixing hooks.
16. Remove the R/C, LED PWB fixing screws (2 pcs.).
R/C, LED PWB
Chassis
Frame Cover
Chassis Frame
Inverter-A
PWB
Inverter-B
PWB
Main PWB
Tuner PWB
11
12
15
13
16
15
15
14
9
LC-20E1E
»
Precautions in handling the LCD panels
1. Work in a clean room (with humidities below 50%).
2. Be sure to wear an anti-static armband.
3. Handle the panels on an electroconductive mat.
4. Be careful not to fall, shake and shock the panels.
17. Remove the LCD panel unit fixing screws (4 pcs.).
18. Remove the ITO earth spring fixing screw (1 pc.).
19. Remove the reflection/deflection, prism, diffusion, ITO sheets and diffusion panel.
20. Remove the lamp fixing holder fixing screws (6 pcs.).
21. Detach the lamp unit-A/B.
22. Remove the reflection mirror fixing screws. (6 pcs.).
22
21
20
18
19
20
17
17
Back shield Panel
 (PSLDM4685CEFW)
Reflection Mirror
 (PMiR-0296CEZZ)
Lamp Fixing Holder
 (LHLDZ2176CEZZ)
Diffusion Panel
 (PCOVU0107CEZZ)
ITO Sheet
 (PSHEP0289CEZZ)
Prism Sheet
 (PSHEP0287CEZZ)
20" LCD Panel Unit
Reflection/Deflection Sheet
 (PSHEP0286CEZZ)
Diffusion Sheet
 (PSHEP0288CEZZ)
ITO Earth Spring
 (MSPRP1220CEFW)
Lamp Fixing Holder
 (LHLDZ2176CEZZ)
Lamp Unit-B
 (KLMP-A125CEZZ)
Lamp Unit-A
 (KLMP-A124CEZZ)
10
LC-20E1E
P6705
SC1201
SC1202
SC1202
P4004
P4004
SC1203
P3702
P2003
P6706
P6705
SC1203
SC2001
SC2001
SC3100
P1903
SC1602
P1903
SC1602
P6706
P3603
P3301
P3302
P3602
P3601
P3601
Inverter-A
PWB
Inverter-B
PWB
Wire holder
Main PWB
Tuner PWB
Main PWB
P3604
P3604
SC2002
7-2
Main unit
(Side B)
2
3
1
5 6
4
R/C, LED PWB
7-3
7-1
Tape
»
Precautions at the time of the side B(back) service of main unit.
1. Remove only SC2001 of the FFC for connection between Main unit(SC2001) and Tuner unit(SC3100), and con-
nect the extended cable (                  ) for service.
2. Remove only P3702 of the FFC for connection between Main unit(P3702) and Tuner unit(P1903), and connect the
extended cable (                   ) for service.
3. Remove only SC2002 of the FFC for connection between Main unit(SC2002) and Tuner unit(SC1602), and con-
nect the extended cable (                   ) for service.
4. Remove the FFC for connection between Main unit(SC1203) and LCD panel unit, and connect the extended cable
(                  ) for service.
5. Remove the FFC for connection between Main unit(SC1202) and LCD panel unit, and connect the extended cable
(                   ) for service.
6. Remove the FFC for connection between Main unit(SC1201) and LCD panel unit, and connect the extended cable
(                  ) for service.
7. Remove the R/C, LED unit.
7-1. Peel off the tape.
7-2. Remove a lead from a wire holder.
7-3. Remove the R/C, LED unit fixing screws(2 pcs.).
8. Remove the main unit fixing screws(3 pcs.), a substrate is reversed.