Sharp 76DW-18H (serv.man32) Service Manual / Technical Bulletin ▷ View online
Sharp Electronics (UK) Limited
Reference JR031299-1
Revision 2
White – Carry out as required, Yellow – Carry out as required and whenever the unit comes in for service, Red – Carry out on all units
CTV991202
Month of Issue: December 1999
Classification: White
TELEVISION TECHNICAL BULLETIN
Page 1 of 1
MODELS
66DW18H
76DW18H
76EF19H
76EF20H
SYMPTOM The following problems can occur on the 100Hz PWB.
•
Intermittent digital noise on the picture
•
Intermittent mosaic squares on the picture
•
Mosaic effect if the 100Hz PWB is tapped
•
Red, green or blue screen if the 100Hz PWB is tapped
CAUSE Problems around the field mixer IC, SDA9270.
•
IC6108 in the 66DW18H and 76DW18H
•
IC6105 in the 76EF19H and 76EF20H
ACTION Carry out the following counter measures.
1. Make sure that there are no dry joints on the Mother PWB
2. Resolder IC6108/IC6105 by reflowing the device - it is not necessary to remove
2. Resolder IC6108/IC6105 by reflowing the device - it is not necessary to remove
IC6108/IC6105
Note that you can operate the 100Hz PWB with the shield cans removed.
It is important that these are returned to there original condition when the job is
completed.
It is important that these are returned to there original condition when the job is
completed.
Display