50Hz Widescreen Colour Television – GA20 Chassis 
 
Sharp Electronics (UK) Ltd 
Technical Support 
Issued June 02 
 
Page 6
 
 
 
Q751
Q752
R743
4K7
R746
4K7
R747
2K2
R758
10K
D759
D758
R749
2K2
R756
12K
Q753
R755
5K6
D761
D760
R754
18K
R766
1K
D774
Q759
D770
R765
1K8
R764
8K2
D766
R774
1K
D775
R781
1K
D773
+5v Stby
-16v
+16v
IC703
R771
15K
+5v Stby
Stby
+10V
R794
1K
Q762
D783
 C787
D784
D787
C12
D785
C6v2
    D786
R795
39K
+14v
CRT
Heaters
C774
1µF
 
Excessive EHT 
If the EHT increases then the horizontal flyback pulses will also increase. The +14v is horizontal 
flyback pulses rectified by D601, Therefore if the EHT increases then the +14v would also increase. 
The +14v is monitored by D785, C774 and R795 and applied to the base of Q762 which is normally 
turned off. When Q762 turns on it will forward bias D770, D759 and D758 causing Q752 to turn on. 
When Q752 turns on Q751 turns on, turning on the thyristor D706 via IC703, removing IC701 Vcc, 
resulting in the power supply entering burst mode. 
CRT Heater Voltage 
An increase in CRT heater voltage has a similar effect to excessive EHT, but this time the monitoring 
component is D787. 
 
50Hz Widescreen Colour Television – GA20 Chassis 
 
Sharp Electronics (UK) Ltd 
Technical Support 
Issued June 02 
 
Page 7
 
 
 
Horizontal Output Stage 
  
The horizontal output stage employed in the GA20 chassis is a conventional transformer driver circuit 
with a diode modulator for the purpose of east west correction. 
  
If the horizontal output stage develops a short circuit, the power supply will operate in burst mode. To 
confirm that it is the horizontal output stage causing burst mode operation; remove the HT feed to 
T602 by disconnecting R606. 
  
Q601
R602
220R
R601
150R
Q1006
T601
R605
5K6
R604
2K7
R607
15R
Q602
R606
3R3
D602
D603
C605
4700pF
C610
8500pF
C611
0.033µF
C608
8100pF
Scan Coils
East/West
C606
150pF
Part of T602
Fly-back TX
C602
560pF
150V
C601
1000pF
IC1001 Pin 76
H-drive
IC1001 Pin 81
H-mµte
4
1
 
  
H
ORIZONTAL 
D
RIVE 
M
UTE
 
  
Q1006 is the horizontal drive muting transistor which is controlled by the microprocessor (IC1001) pin 
81, At switch on IC1001 pin 81 is high, keeping Q1006 turned on, shorting the horizontal drive to 
ground. Once IC1001 start-up sequence is complete and it is ready to allow the horizontal stage to 
start, pin 81 will go low turning off Q1006, allowing the horizontal drive to reach the driver transistor 
Q601. 
  
If at any time the microprocessor detects a fault where it needs to stop the horizontal drive for safety 
reasons then Q1006 will be turned on again. 
H
ORIZONTAL 
O
UTPUT 
T
HEORY
 
Consider the circuit at rest, i.e. the beam spot at the centre and no current flowing through the scan 
coils. The S-correction (DC blocking) and the fly back tuning capacitor charged. 
  
Scan Coils
  
S-Correction
Fly-Back Tuning
Capacitor
Efficiency
Diode
Horizontal
Output
Direction Of Scan
 
  
Scan is initiated when the horizontal output transistor is switched on.  
  
50Hz Widescreen Colour Television – GA20 Chassis 
 
Sharp Electronics (UK) Ltd 
Technical Support 
Issued June 02 
 
Page 8
 
 
 
Scan Coils
  
S-Correction
Fly-Back Tuning
Capacitor
Efficiency
Diode
Horizontal
Output
Direction Of Scan
 
  
This causes current to flow through the scan coils from the S-correction capacitor, which results in a 
linear build up of magnetic energy in the scan coils that will move the beam spot from the centre 
position towards the right hand edge of the CRT. 
  
Scan Coils
  
S-Correction
Fly-Back Tuning
Capacitor
Efficiency
Diode
Horizontal
Output
Direction Of Scan
 
  
At the point where horizontal drive pulse returns to zero, and the horizontal output transistor turns off. 
The magnetic energy that has built up in the scan coils begins to collapse at a rate determined by the 
flyback tuning capacitors. A back emf is produced by this collapsing magnetic field which charges the 
flyback tuning capacitor. The spot will now move from the right hand edge of the CRT towards the left 
at a higher speed. When the beam spot reaches the centre position the current through the scan coils 
(magnetic field totally collapsed) is at a minimum and the voltage across the flyback tuning capacitor 
is at a maximum. The charge that has been built up in the flyback tuning capacitor will now flow in the 
reverse direction through the scan coils keeping the beam spot moving towards the left hand side of 
the CRT. 
  
When the voltage across the tuning capacitor becomes zero all the energy is now stored in the scan 
coils as a magnetic field, flyback is completed. 
  
Scan Coils
  
S-Correction
Fly-Back Tuning
Capacitor
Efficiency
Diode
Horizontal
Output
Direction Of Scan
 
  
As a linear scanning current is required, the oscillation set up in the scan coils and tuning capacitors 
during flyback has to be stopped. If resistance were used to damp the oscillation (15625 times/sec) 
the stored energy would be wasted. The oscillation is damped by a diode connected across the 
collector/emitter (can be encapsulated within the transistor). 
  
50Hz Widescreen Colour Television – GA20 Chassis 
 
Sharp Electronics (UK) Ltd 
Technical Support 
Issued June 02 
 
Page 9
 
 
 
As the magnetic field starts to collapse the back emf produced forward biases the diode and the 
energy is returned to the circuit, effectively damping the oscillation, and the beam spot moves back to 
the centre of the CRT in a linear fashion. 
  
Scan Coils
  
S-Correction
Fly-Back Tuning
Capacitor
Efficiency
Diode
Horizontal
Output
Direction Of Scan
 
  
As energy is saved by the action of the diode, it is referred to as the Efficiency Diode. 
  
As the beam spot returns to the centre position the next horizontal drive pulse arrives and the process 
continues. 
 