DOWNLOAD Sharp 28JW-73H (serv.man2) Service Manual ↓ Size: 2.38 MB | Pages: 40 in PDF or view online for FREE

Model
28JW-73H (serv.man2)
Pages
40
Size
2.38 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / CTR / GA20 Chassis Training Notes
File
28jw-73h-sm2.pdf
Date

Sharp 28JW-73H (serv.man2) Service Manual ▷ View online

50Hz Widescreen Colour Television – GA20 Chassis 
 
Sharp Electronics (UK) Ltd 
Technical Support 
Issued June 02 
 
Page 3
 
 
 
Control (Pin 3) 
Burst Standby mode 
The CTRL pin (pin 3) is also used to implement the burst mode standby. In burst mode standby, the 
power supply enters a special low dissipation state, where it typically consumes less than 1W of input 
power, but is still able to supply a microprocessor. The system enters burst mode standby when the 
microprocessor turns on Q754 in the isolated side of the power supply which will result in the opto-
coupler, IC702 turning on, taking the control pin of the TEA1507 high. In response to this signal, the 
IC stops switching and enters a ‘hiccup’ mode. This burst activation signal should be present for a 
period, longer than  30 ms. 
Hiccup Mode 
The hiccup mode during burst mode standby operation does not differ from the hiccup mode in safe-
restart mode during a system fault condition (e.g. OVP or output short circuit). 
 Demagnetization (Pin 4) 
The system will be in discontinuous conduction mode all the time. The internal oscillator will not start 
a new primary stroke until the secondary stroke has ended. Demagnetization features a cycle-by-
cycle output short-circuit protection by immediately lowering the frequency (longer off-time), thereby 
reducing the power level. 
 
Demagnetization recognition is suppressed during the first tsuppr time. This suppression may be 
necessary in applications where the transformer has a large leakage inductance and at low output 
voltages/start-up. 
Overvoltage 
An overvoltage (OVP) mode is implemented by sensing the voltage via the current flowing into pin 4 
DEM during the secondary stroke. The secondary winding voltage is a well-defined replica of the 
output voltage. Any voltage spikes are averaged by an internal filter. If the output voltage exceeds the 
OVP trip level, the OVP circuit switches Q702. Next, the controller waits until the UVLO level is 
reached on pin 1, VCC. This is followed by a safe restart cycle, after which switching starts again. 
This process is repeated as long as the OVP condition exists. The output voltage at which the OVP 
function trips, Vo(OVP) is set by the series/parallel network comprising of R706, R709, R710, R714 
and D701 
Overpower 
This pin is also used to monitor the power that is being drawn 'Overpower Protection' (OPP) During 
the primary stroke, the rectified mains input voltage is measured by sensing the current drawn from 
pin 4 (DEM). 
The current information is used to adjust the peak drain current, which is measured via pin 5 (I
sense
). 
The internal compensation is such that an almost mains independent maximum output power can be 
realised. 
Current Sense (Pin 5) 
Short Winding Protection 
After the leading edge blanking time, the short winding protection circuit is activated. If the ‘sense’ 
voltage exceeds the short winding protection voltage Vswp, the converter will stop switching. Once 
V
CC
 drops below the UVLO level, capacitor C705 will be recharged and the supply will restart again. 
50Hz Widescreen Colour Television – GA20 Chassis 
 
Sharp Electronics (UK) Ltd 
Technical Support 
Issued June 02 
 
Page 4
 
 
 
This cycle will be repeated until the short circuit is removed (safe restart mode). The short winding 
protection will also protect in case of a secondary diode short circuit. 
Overcurrent 
The cycle-by-cycle peak drain current limit circuit uses the external source resistor (R715) to measure 
the current accurately. The circuit is activated after the leading edge. The Overcurrent Protection 
(OCP) circuit limits the ‘sense’ voltage to an internal level. 
Typical Voltage at pin 5 <0.56v 
Soft Start 
To prevent transformer rattle during hiccup mode, the transformer peak current is slowly increased by 
the soft start function. This is be achieved by inserting a resistor (R713) and a capacitor (C706) 
between pin 5 (I
sense
) and the sense resistor (R715). An internal current source charges the capacitor 
to a voltage that is derived from Iss X R713 to a maximum value of approximately 0.5 V. 
Drive (Pin 6) 
This is the drive to Q702 gate. the duty cycle of this signal is dependant on the conditions at the other 
pins of the TEA1507. The driver circuit to the gate of Q702 has a current sourcing capability of 
typically 125 mA and a current sink capability of typical 540 mA. This permits fast turn-on and turn-off 
of Q702 for efficient operation. This low driver source current reduces Electro Magnetic Interference 
(EMI) and also limits the current spikes across R715. 
HT
 
R
EGULATION
 
D758 is a variable zener diode. When the voltage increases on the control pin the zener point fails. 
This control pin is connected to the 150v rail via the potential divider network of R750, R751, R752 
and R753. Therefore for an increase in HT D758 turns on earlier, which in turn will turn on the opto-
coupler IC702, turning off the power supply. For a low HT then the zener point of D758 increases 
keeping IC703 turned off. 
 
IC702
D776
R744
1K
D754
R757
47K
D712
C12
D757
Q754
C753
0.27µF
D758
R742
47R
C751
1µF
R748
330K
R752
4K7
R753
47K
R751
120K
R750
120K
IC751
+5v
CTL
IN
150v
IC1001 pin 33
(Standby)
14
13
Part
of
T703
+7.5v
50Hz Widescreen Colour Television – GA20 Chassis 
 
Sharp Electronics (UK) Ltd 
Technical Support 
Issued June 02 
 
Page 5
 
 
 
S
TANDBY
 
During standby Q754 is turned on by the microprocessor which has the effect of connecting D757 and 
D712 in parallel across D758. This will keep the opto-coupler (IC702) turned on, simulating an over 
voltage condition. IC701 is now operating in burst mode. 
S
ECONDARY 
P
ROTECTION
 
In the event that a secondary supply rails fails due to excessive current or increases beyond safe 
limits then this power supply is designed to return to the burst start-up mode. 
 
Q704
D712
Q701
R717
10K
R719
10K
D706
R723
2K2
R707
150K
R703
150K
D710
C15
R725
2K7
D708
R724
10R
+350v
IC701 Pin 4
(demag)
1
2
Part
of
T703
IC702
IC701 Pin 1
(vcc)
IC701 Pin 3
(ctl)
IC703
C714
22µF
C705
22µF
 
 
This is achieved by a supply rail monitoring circuit which consisting of Q751, Q752, Q753, Q762 and 
Q759, and a control circuit consisting of IC703, Q701, D706 and D712.  
 
The  opto-coupler (IC703) is normally turned off. If it is turns on, then thyristor D706 will conduct, 
turning on Q701. Q701 emitter is connected to power supply ground and its collector is connected via 
D712 to IC701 pin 1 (VCC ). Therefore, while Q701 is turned on it is impossible for the voltage at  
IC701 pin 1  (VCC) to reach its turn on threshold, hence the power supply remains in burst mode. 
50Hz Widescreen Colour Television – GA20 Chassis 
 
Sharp Electronics (UK) Ltd 
Technical Support 
Issued June 02 
 
Page 6
 
 
 
Q751
Q752
R743
4K7
R746
4K7
R747
2K2
R758
10K
D759
D758
R749
2K2
R756
12K
Q753
R755
5K6
D761
D760
R754
18K
R766
1K
D774
Q759
D770
R765
1K8
R764
8K2
D766
R774
1K
D775
R781
1K
D773
+5v Stby
-16v
+16v
IC703
R771
15K
+5v Stby
Stby
+10V
R794
1K
Q762
D783
 C787
D784
D787
C12
D785
C6v2
    D786
R795
39K
+14v
CRT
Heaters
C774
1µF
 
Excessive EHT 
If the EHT increases then the horizontal flyback pulses will also increase. The +14v is horizontal 
flyback pulses rectified by D601, Therefore if the EHT increases then the +14v would also increase. 
The +14v is monitored by D785, C774 and R795 and applied to the base of Q762 which is normally 
turned off. When Q762 turns on it will forward bias D770, D759 and D758 causing Q752 to turn on. 
When Q752 turns on Q751 turns on, turning on the thyristor D706 via IC703, removing IC701 Vcc, 
resulting in the power supply entering burst mode. 
CRT Heater Voltage 
An increase in CRT heater voltage has a similar effect to excessive EHT, but this time the monitoring 
component is D787. 
 
Page of 40
Display

Click on the first or last page to see other 28JW-73H (serv.man2) service manuals if exist.